{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27897"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27897","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Experimental Investigation of Airlift Pumps as Heat and Mass Transfer Devices for Waste Heat Recovery and Carbon Capture","abstract":"Airlift pumps are used extensively in aquaculture, oil and gas applications, and wastewater treatment facilities due to their high pumping efficiency and low maintenance requirements. Primarily employed to transport liquids, sludges and slurries under low pressure conditions, airlift pumps also facilitate interfacial heat and mass transfer between gas and liquid phases. This capability warrants the investigation of airlift pumps as heat and mass exchange devices. This study experimentally characterizes sensible heat and evaporative mass transfer performance and quantifies the CO2 capture capacity of a dual injection gas-lift pump operating under two-phase flow conditions. A state-of-the-art experimental gas-lift pump loop was commissioned, and a series of experiments were performed under both isothermal and non-isothermal two-phase flow conditions to simulate the carbon capture capabilities of flue gas with volumetric CO2 concentration ranging from 0 – 25%.","abstract_html":"Airlift pumps are used extensively in aquaculture, oil and gas applications, and wastewater treatment facilities due to their high pumping efficiency and low maintenance requirements. Primarily employed to transport liquids, sludges and slurries under low pressure conditions, airlift pumps also facilitate interfacial heat and mass transfer between gas and liquid phases. This capability warrants the investigation of airlift pumps as heat and mass exchange devices. This study experimentally characterizes sensible heat and evaporative mass transfer performance and quantifies the CO2 capture capacity of a dual injection gas-lift pump operating under two-phase flow conditions. A state-of-the-art experimental gas-lift pump loop was commissioned, and a series of experiments were performed under both isothermal and non-isothermal two-phase flow conditions to simulate the carbon capture capabilities of flue gas with volumetric CO2 concentration ranging from 0 – 25%.","abstract_has_math":false,"creators":["Doucette, Alexander"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ahmed, Wael"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:25:42Z","subjects":["carbon capture","airlift pump","waste heat recovery","two phase flow","direct contact heat transfer","direct contact mass transfer"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27897","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27897","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2024-08-29","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27897","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27897","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Wael"]},{"key":"dc:creator","label":"Author","values":["Doucette, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-09-12T18:14:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-12T18:14:49Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08-28"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2024-08-29"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["carbon capture","airlift pump","waste heat recovery","two phase flow","direct contact heat transfer","direct contact mass transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27897"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Airlift pumps are used extensively in aquaculture, oil and gas applications, and wastewater treatment facilities due to their high pumping efficiency and low maintenance requirements. Primarily employed to transport liquids, sludges and slurries under low pressure conditions, airlift pumps also facilitate interfacial heat and mass transfer between gas and liquid phases. This capability warrants the investigation of airlift pumps as heat and mass exchange devices. This study experimentally characterizes sensible heat and evaporative mass transfer performance and quantifies the CO2 capture capacity of a dual injection gas-lift pump operating under two-phase flow conditions. A state-of-the-art experimental gas-lift pump loop was commissioned, and a series of experiments were performed under both isothermal and non-isothermal two-phase flow conditions to simulate the carbon capture capabilities of flue gas with volumetric CO2 concentration ranging from 0 – 25%."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Ontario Ministry of Agriculture, Food and Rural Affairs"]},{"key":"dc:title","label":"Title","values":["Experimental Investigation of Airlift Pumps as Heat and Mass Transfer Devices for Waste Heat Recovery and Carbon Capture"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahmed, Wael"],"dc:creator":["Doucette, Alexander"],"dc:date.accessioned":["2023-09-12T18:14:49Z"],"dc:date.available":["2023-09-12T18:14:49Z"],"dc:date.copyright":["2023-09"],"dc:date.created":["2023-08-28"],"dc:date.embargo":["2024-08-29"],"dc:description.abstract":["Airlift pumps are used extensively in aquaculture, oil and gas applications, and wastewater treatment facilities due to their high pumping efficiency and low maintenance requirements. Primarily employed to transport liquids, sludges and slurries under low pressure conditions, airlift pumps also facilitate interfacial heat and mass transfer between gas and liquid phases. This capability warrants the investigation of airlift pumps as heat and mass exchange devices. This study experimentally characterizes sensible heat and evaporative mass transfer performance and quantifies the CO2 capture capacity of a dual injection gas-lift pump operating under two-phase flow conditions. A state-of-the-art experimental gas-lift pump loop was commissioned, and a series of experiments were performed under both isothermal and non-isothermal two-phase flow conditions to simulate the carbon capture capabilities of flue gas with volumetric CO2 concentration ranging from 0 – 25%."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Ontario Ministry of Agriculture, Food and Rural Affairs"],"dc:identifier.uri":["https://hdl.handle.net/10214/27897"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["carbon capture","airlift pump","waste heat recovery","two phase flow","direct contact heat transfer","direct contact mass transfer"],"dc:title":["Experimental Investigation of Airlift Pumps as Heat and Mass Transfer Devices for Waste Heat Recovery and Carbon Capture"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:42Z"}