{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27941"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27941","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Assessing Methods to Monitor Rivaroxaban Therapy and the Viability of the Calibrated Automated Thrombogram (CAT) using Low Plasma Volumes in Dogs","abstract":"Hypercoagulability, thrombosis, and the use of anti-thrombotic drugs in companion animals are important areas of research in veterinary medicine. There is a paucity of information regarding dosing, effect, and monitoring of anti-thrombotic drugs, such as rivaroxaban, in clinically ill animals.In the first study, 12 client-owned dogs diagnosed with hypercoagulability and/or thromboembolic disease and prescribed rivaroxaban, were recruited. Blood samples were collected prior to treatment, then 1-week and 1 to 3-months after initiation of therapy. The hemostatic tests prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, rivaroxaban specific anti-Xa assay (raXa), thromboelastography (TEG) with strong activators, and thrombin generation (TG) were performed at each visit (3 hours after rivaroxaban dosing). There was a strong correlation between raXa and PT (p<0.001). The raXa was strongly positively correlated with TG variables- time to peak (ttpeak, p<0.001) and lag time (lag time, p<0.001), and negatively correlated with TG variables- endogenous thrombin potential (ETP, p<0.001) and peak (peak, p<0.001). There was poor correlation between raXa and aPTT, fibrinogen, and all TEG variables.In the second study, archived plasma samples from dogs previously determined to have low (hypocoagulable, n=10), normal (n=10), and high (hypercoagulable, n=10) thrombin generation potential were used. Method comparison was performed for the calibrated automated thrombogram (CAT) using standard (80 μL plasma, 20 μL reagent- method 1) and low volume (40 μL plasma, 10 μL reagent- method 2) plasma and reagent, respectively. Four parameters of the TG curve were assessed: lag time; ETP; peak; and ttpeak. There was excellent agreement between methods 1 and 2 for all parameters.In conclusion, PT and TG were found to strongly correlate with raXa and may be a convenient method to monitor hypercoagulable dogs receiving rivaroxaban therapy. Additionally, low volume CAT appears to be a valid alternative to the standard testing method in dogs with a range of thrombin generation potentials.","abstract_html":"Hypercoagulability, thrombosis, and the use of anti-thrombotic drugs in companion animals are important areas of research in veterinary medicine. There is a paucity of information regarding dosing, effect, and monitoring of anti-thrombotic drugs, such as rivaroxaban, in clinically ill animals.In the first study, 12 client-owned dogs diagnosed with hypercoagulability and/or thromboembolic disease and prescribed rivaroxaban, were recruited. Blood samples were collected prior to treatment, then 1-week and 1 to 3-months after initiation of therapy. The hemostatic tests prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, rivaroxaban specific anti-Xa assay (raXa), thromboelastography (TEG) with strong activators, and thrombin generation (TG) were performed at each visit (3 hours after rivaroxaban dosing). There was a strong correlation between raXa and PT (p&lt;0.001). The raXa was strongly positively correlated with TG variables- time to peak (ttpeak, p&lt;0.001) and lag time (lag time, p&lt;0.001), and negatively correlated with TG variables- endogenous thrombin potential (ETP, p&lt;0.001) and peak (peak, p&lt;0.001). There was poor correlation between raXa and aPTT, fibrinogen, and all TEG variables.In the second study, archived plasma samples from dogs previously determined to have low (hypocoagulable, n=10), normal (n=10), and high (hypercoagulable, n=10) thrombin generation potential were used. Method comparison was performed for the calibrated automated thrombogram (CAT) using standard (80 μL plasma, 20 μL reagent- method 1) and low volume (40 μL plasma, 10 μL reagent- method 2) plasma and reagent, respectively. Four parameters of the TG curve were assessed: lag time; ETP; peak; and ttpeak. There was excellent agreement between methods 1 and 2 for all parameters.In conclusion, PT and TG were found to strongly correlate with raXa and may be a convenient method to monitor hypercoagulable dogs receiving rivaroxaban therapy. Additionally, low volume CAT appears to be a valid alternative to the standard testing method in dogs with a range of thrombin generation potentials.","abstract_has_math":false,"creators":["Phillips, Erin"],"institution":"University of Guelph","degree_name":"Doctor of Veterinary Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Clinical Studies","school":null,"contributors":[],"advisors":["Blois, Shauna"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:26:14Z","subjects":["rivaroxaban","dog","thrombin generation","prothrombin time"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27941","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27941","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2024-08-23","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27941","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27941","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Blois, Shauna"]},{"key":"dc:creator","label":"Author","values":["Phillips, Erin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-09-15T19:33:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-15T19:33:22Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08-23"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2024-08-23"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Clinical Studies"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Veterinary Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Clinical Studies"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["rivaroxaban","dog","thrombin generation","prothrombin time"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27941"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hypercoagulability, thrombosis, and the use of anti-thrombotic drugs in companion animals are important areas of research in veterinary medicine. There is a paucity of information regarding dosing, effect, and monitoring of anti-thrombotic drugs, such as rivaroxaban, in clinically ill animals.In the first study, 12 client-owned dogs diagnosed with hypercoagulability and/or thromboembolic disease and prescribed rivaroxaban, were recruited. Blood samples were collected prior to treatment, then 1-week and 1 to 3-months after initiation of therapy. The hemostatic tests prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, rivaroxaban specific anti-Xa assay (raXa), thromboelastography (TEG) with strong activators, and thrombin generation (TG) were performed at each visit (3 hours after rivaroxaban dosing). There was a strong correlation between raXa and PT (p<0.001). The raXa was strongly positively correlated with TG variables- time to peak (ttpeak, p<0.001) and lag time (lag time, p<0.001), and negatively correlated with TG variables- endogenous thrombin potential (ETP, p<0.001) and peak (peak, p<0.001). There was poor correlation between raXa and aPTT, fibrinogen, and all TEG variables.In the second study, archived plasma samples from dogs previously determined to have low (hypocoagulable, n=10), normal (n=10), and high (hypercoagulable, n=10) thrombin generation potential were used. Method comparison was performed for the calibrated automated thrombogram (CAT) using standard (80 μL plasma, 20 μL reagent- method 1) and low volume (40 μL plasma, 10 μL reagent- method 2) plasma and reagent, respectively. Four parameters of the TG curve were assessed: lag time; ETP; peak; and ttpeak. There was excellent agreement between methods 1 and 2 for all parameters.In conclusion, PT and TG were found to strongly correlate with raXa and may be a convenient method to monitor hypercoagulable dogs receiving rivaroxaban therapy. Additionally, low volume CAT appears to be a valid alternative to the standard testing method in dogs with a range of thrombin generation potentials."]},{"key":"dc:title","label":"Title","values":["Assessing Methods to Monitor Rivaroxaban Therapy and the Viability of the Calibrated Automated Thrombogram (CAT) using Low Plasma Volumes in Dogs"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Blois, Shauna"],"dc:creator":["Phillips, Erin"],"dc:date.accessioned":["2023-09-15T19:33:22Z"],"dc:date.available":["2023-09-15T19:33:22Z"],"dc:date.copyright":["2023-08"],"dc:date.created":["2023-08-23"],"dc:date.embargo":["2024-08-23"],"dc:description.abstract":["Hypercoagulability, thrombosis, and the use of anti-thrombotic drugs in companion animals are important areas of research in veterinary medicine. There is a paucity of information regarding dosing, effect, and monitoring of anti-thrombotic drugs, such as rivaroxaban, in clinically ill animals.In the first study, 12 client-owned dogs diagnosed with hypercoagulability and/or thromboembolic disease and prescribed rivaroxaban, were recruited. Blood samples were collected prior to treatment, then 1-week and 1 to 3-months after initiation of therapy. The hemostatic tests prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, rivaroxaban specific anti-Xa assay (raXa), thromboelastography (TEG) with strong activators, and thrombin generation (TG) were performed at each visit (3 hours after rivaroxaban dosing). There was a strong correlation between raXa and PT (p<0.001). The raXa was strongly positively correlated with TG variables- time to peak (ttpeak, p<0.001) and lag time (lag time, p<0.001), and negatively correlated with TG variables- endogenous thrombin potential (ETP, p<0.001) and peak (peak, p<0.001). There was poor correlation between raXa and aPTT, fibrinogen, and all TEG variables.In the second study, archived plasma samples from dogs previously determined to have low (hypocoagulable, n=10), normal (n=10), and high (hypercoagulable, n=10) thrombin generation potential were used. Method comparison was performed for the calibrated automated thrombogram (CAT) using standard (80 μL plasma, 20 μL reagent- method 1) and low volume (40 μL plasma, 10 μL reagent- method 2) plasma and reagent, respectively. Four parameters of the TG curve were assessed: lag time; ETP; peak; and ttpeak. There was excellent agreement between methods 1 and 2 for all parameters.In conclusion, PT and TG were found to strongly correlate with raXa and may be a convenient method to monitor hypercoagulable dogs receiving rivaroxaban therapy. Additionally, low volume CAT appears to be a valid alternative to the standard testing method in dogs with a range of thrombin generation potentials."],"dc:identifier.uri":["https://hdl.handle.net/10214/27941"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["rivaroxaban","dog","thrombin generation","prothrombin time"],"dc:title":["Assessing Methods to Monitor Rivaroxaban Therapy and the Viability of the Calibrated Automated Thrombogram (CAT) using Low Plasma Volumes in Dogs"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Clinical Studies"],"thesis:degree_name":["Doctor of Veterinary Science"],"thesis:degree_program":["Clinical Studies"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:14Z"}