{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27964"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27964","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Probing the Spatial Acuity of the Thigh for Enhanced Sensory","abstract":"Amputation impairs sensory feedback and limb movement. Embedding tactile displays in transfemoral prosthetic sockets to convey movement cues through varied vibration patterns is seen as a promising avenue. To optimize the functionality of such displays, it is essential to determine the minimum distance required to discriminate between two distinct sources of vibration. This thesis aims to address this crucial requirement and explore any variations in the ability to perceive distinct vibration points due to vibration frequency. The distances needed for discerning separate vibration points at the thigh were determined to be between 25mm and 30 mm. Results highlight that frequency did not enhance spatial acuity. The findings also revealed a higher accuracy in discriminating vertically oriented vibration points compared to horizontally oriented ones. This thesis' outcomes offer important insights for designing a tactile display that enables users to precisely perceive and respond to various vibration patterns.","abstract_html":"Amputation impairs sensory feedback and limb movement. Embedding tactile displays in transfemoral prosthetic sockets to convey movement cues through varied vibration patterns is seen as a promising avenue. To optimize the functionality of such displays, it is essential to determine the minimum distance required to discriminate between two distinct sources of vibration. This thesis aims to address this crucial requirement and explore any variations in the ability to perceive distinct vibration points due to vibration frequency. The distances needed for discerning separate vibration points at the thigh were determined to be between 25mm and 30 mm. Results highlight that frequency did not enhance spatial acuity. The findings also revealed a higher accuracy in discriminating vertically oriented vibration points compared to horizontally oriented ones. This thesis&#x27; outcomes offer important insights for designing a tactile display that enables users to precisely perceive and respond to various vibration patterns.","abstract_has_math":false,"creators":["Genaro, Daniel"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Human Health and Nutritional Sciences","school":null,"contributors":[],"advisors":["Bent, Leah R."],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:25:20Z","subjects":["sensory substitution","two-point discrimination","psychophysics","prostheses"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27964","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27964","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27964","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27964","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bent, Leah R."]},{"key":"dc:creator","label":"Author","values":["Genaro, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-10-05T16:18:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-10-05T16:18:11Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-09-20"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Human Health and Nutritional Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Human Health and Nutritional Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["sensory substitution","two-point discrimination","psychophysics","prostheses"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27964"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Amputation impairs sensory feedback and limb movement. Embedding tactile displays in transfemoral prosthetic sockets to convey movement cues through varied vibration patterns is seen as a promising avenue. To optimize the functionality of such displays, it is essential to determine the minimum distance required to discriminate between two distinct sources of vibration. This thesis aims to address this crucial requirement and explore any variations in the ability to perceive distinct vibration points due to vibration frequency. The distances needed for discerning separate vibration points at the thigh were determined to be between 25mm and 30 mm. Results highlight that frequency did not enhance spatial acuity. The findings also revealed a higher accuracy in discriminating vertically oriented vibration points compared to horizontally oriented ones. This thesis' outcomes offer important insights for designing a tactile display that enables users to precisely perceive and respond to various vibration patterns."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Mitacs"]},{"key":"dc:title","label":"Title","values":["Probing the Spatial Acuity of the Thigh for Enhanced Sensory"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bent, Leah R."],"dc:creator":["Genaro, Daniel"],"dc:date.accessioned":["2023-10-05T16:18:11Z"],"dc:date.available":["2023-10-05T16:18:11Z"],"dc:date.copyright":["2023"],"dc:date.created":["2023-09-20"],"dc:description.abstract":["Amputation impairs sensory feedback and limb movement. Embedding tactile displays in transfemoral prosthetic sockets to convey movement cues through varied vibration patterns is seen as a promising avenue. To optimize the functionality of such displays, it is essential to determine the minimum distance required to discriminate between two distinct sources of vibration. This thesis aims to address this crucial requirement and explore any variations in the ability to perceive distinct vibration points due to vibration frequency. The distances needed for discerning separate vibration points at the thigh were determined to be between 25mm and 30 mm. Results highlight that frequency did not enhance spatial acuity. The findings also revealed a higher accuracy in discriminating vertically oriented vibration points compared to horizontally oriented ones. This thesis' outcomes offer important insights for designing a tactile display that enables users to precisely perceive and respond to various vibration patterns."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Mitacs"],"dc:identifier.uri":["https://hdl.handle.net/10214/27964"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["sensory substitution","two-point discrimination","psychophysics","prostheses"],"dc:title":["Probing the Spatial Acuity of the Thigh for Enhanced Sensory"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Human Health and Nutritional Sciences"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Human Health and Nutritional Sciences"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:20Z"}