{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28091"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28091","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Evaluation of Groundwater Flow Features and Flow Rates Through a DNAPL-Impacted Source Zone in Fractured Sedimentary Rock","abstract":"This study applied a Fiber Optic Active Distributed Temperature Sensing (A-DTS) approach to identify hydraulically active fractures, quantify depth-discrete volumetric groundwater flow rates (Q), and evaluate methods used to inform rock thermal conductivity variability in heterogeneous bedrock aquifers. This was done in a DNAPL-impacted source zone to characterize the preferential pathways for groundwater flow, evaluate the fracture characteristics affecting the variable Q values, and quantify contaminant mass discharge. This study employed an improved method for creating rock thermal conductivity profiles, relying on depth-discrete core samples as a baseline. These profiles were used to estimate horizontal groundwater flow with apparent thermal conductivity values, based on the A-DTS approach, to assess the reasonableness for identifying hydraulically active fractures in boreholes. Additionally, this work discusses possible causes of vertical flow along the fiber optic cable that partially limited the ability to identify hydraulically active fractures and, at times, resulted in overestimates of Q.","abstract_html":"This study applied a Fiber Optic Active Distributed Temperature Sensing (A-DTS) approach to identify hydraulically active fractures, quantify depth-discrete volumetric groundwater flow rates (Q), and evaluate methods used to inform rock thermal conductivity variability in heterogeneous bedrock aquifers. This was done in a DNAPL-impacted source zone to characterize the preferential pathways for groundwater flow, evaluate the fracture characteristics affecting the variable Q values, and quantify contaminant mass discharge. This study employed an improved method for creating rock thermal conductivity profiles, relying on depth-discrete core samples as a baseline. These profiles were used to estimate horizontal groundwater flow with apparent thermal conductivity values, based on the A-DTS approach, to assess the reasonableness for identifying hydraulically active fractures in boreholes. Additionally, this work discusses possible causes of vertical flow along the fiber optic cable that partially limited the ability to identify hydraulically active fractures and, at times, resulted in overestimates of Q.","abstract_has_math":false,"creators":["Leahey, Michelle"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Parker, Beth"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:24:43Z","subjects":["groundwater flow features","flow rates","rock thermal conductivity profiles","sedimentary rock"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28091","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28091","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28091","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parker, Beth"]},{"key":"dc:creator","label":"Author","values":["Leahey, Michelle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-11T15:44:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-11T15:44:52Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-09-22"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["groundwater flow features","flow rates","rock thermal conductivity profiles","sedimentary rock"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28091"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study applied a Fiber Optic Active Distributed Temperature Sensing (A-DTS) approach to identify hydraulically active fractures, quantify depth-discrete volumetric groundwater flow rates (Q), and evaluate methods used to inform rock thermal conductivity variability in heterogeneous bedrock aquifers. This was done in a DNAPL-impacted source zone to characterize the preferential pathways for groundwater flow, evaluate the fracture characteristics affecting the variable Q values, and quantify contaminant mass discharge. This study employed an improved method for creating rock thermal conductivity profiles, relying on depth-discrete core samples as a baseline. These profiles were used to estimate horizontal groundwater flow with apparent thermal conductivity values, based on the A-DTS approach, to assess the reasonableness for identifying hydraulically active fractures in boreholes. Additionally, this work discusses possible causes of vertical flow along the fiber optic cable that partially limited the ability to identify hydraulically active fractures and, at times, resulted in overestimates of Q."]},{"key":"dc:title","label":"Title","values":["Evaluation of Groundwater Flow Features and Flow Rates Through a DNAPL-Impacted Source Zone in Fractured Sedimentary Rock"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parker, Beth"],"dc:creator":["Leahey, Michelle"],"dc:date.accessioned":["2024-01-11T15:44:52Z"],"dc:date.available":["2024-01-11T15:44:52Z"],"dc:date.copyright":["2024-01"],"dc:date.created":["2024-09-22"],"dc:description.abstract":["This study applied a Fiber Optic Active Distributed Temperature Sensing (A-DTS) approach to identify hydraulically active fractures, quantify depth-discrete volumetric groundwater flow rates (Q), and evaluate methods used to inform rock thermal conductivity variability in heterogeneous bedrock aquifers. This was done in a DNAPL-impacted source zone to characterize the preferential pathways for groundwater flow, evaluate the fracture characteristics affecting the variable Q values, and quantify contaminant mass discharge. This study employed an improved method for creating rock thermal conductivity profiles, relying on depth-discrete core samples as a baseline. These profiles were used to estimate horizontal groundwater flow with apparent thermal conductivity values, based on the A-DTS approach, to assess the reasonableness for identifying hydraulically active fractures in boreholes. Additionally, this work discusses possible causes of vertical flow along the fiber optic cable that partially limited the ability to identify hydraulically active fractures and, at times, resulted in overestimates of Q."],"dc:identifier.uri":["https://hdl.handle.net/10214/28091"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["groundwater flow features","flow rates","rock thermal conductivity profiles","sedimentary rock"],"dc:title":["Evaluation of Groundwater Flow Features and Flow Rates Through a DNAPL-Impacted Source Zone in Fractured Sedimentary Rock"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:43Z"}