{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28098"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28098","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Application of passive sampling for the monitoring of microbiological contaminants in aquatic systems","abstract":"Traditional methods for monitoring pathogens in environmental waters have numerous drawbacks. In our systematic review, we found few studies that monitored bacteria in any water source using membrane filters as passive samplers. Therefore, to fill this data gap, we assessed the efficacy of passive sampling compared to composite sampling for the monitoring of E. coli onto membrane passive samplers over time. We observed similar rates for E. coli detections on passive samplers compared to composite samples in surface water and wastewater. We found significant linear accumulation of E. coli onto passive samplers throughout the entire 96 hours of deployment in surface water (R2 = 0.942; p = 0.001). In wastewater, passive samplers reached maximum concentration after 24 hours before plateauing. Passive sampling is an effective, low-cost, time-efficient, and practical method for monitoring E. coli in surface water and wastewater and may be applicable to other bacteria.","abstract_html":"Traditional methods for monitoring pathogens in environmental waters have numerous drawbacks. In our systematic review, we found few studies that monitored bacteria in any water source using membrane filters as passive samplers. Therefore, to fill this data gap, we assessed the efficacy of passive sampling compared to composite sampling for the monitoring of E. coli onto membrane passive samplers over time. We observed similar rates for E. coli detections on passive samplers compared to composite samples in surface water and wastewater. We found significant linear accumulation of E. coli onto passive samplers throughout the entire 96 hours of deployment in surface water (R2 = 0.942; p = 0.001). In wastewater, passive samplers reached maximum concentration after 24 hours before plateauing. Passive sampling is an effective, low-cost, time-efficient, and practical method for monitoring E. coli in surface water and wastewater and may be applicable to other bacteria.","abstract_has_math":false,"creators":["Law, Ilya"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Pathobiology","school":null,"contributors":[],"advisors":["Murphy, Heather"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:21:17Z","subjects":["passive samplers","membrane filters","E. coli","water quality monitoring","wastewater surveillance"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28098","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28098","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F28098","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28098","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Murphy, Heather"]},{"key":"dc:creator","label":"Author","values":["Law, Ilya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-11T20:27:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-11T20:27:21Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Pathobiology"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Pathobiology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["passive samplers","membrane filters","E. coli","water quality monitoring","wastewater surveillance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28098"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Traditional methods for monitoring pathogens in environmental waters have numerous drawbacks. In our systematic review, we found few studies that monitored bacteria in any water source using membrane filters as passive samplers. Therefore, to fill this data gap, we assessed the efficacy of passive sampling compared to composite sampling for the monitoring of E. coli onto membrane passive samplers over time. We observed similar rates for E. coli detections on passive samplers compared to composite samples in surface water and wastewater. We found significant linear accumulation of E. coli onto passive samplers throughout the entire 96 hours of deployment in surface water (R2 = 0.942; p = 0.001). In wastewater, passive samplers reached maximum concentration after 24 hours before plateauing. Passive sampling is an effective, low-cost, time-efficient, and practical method for monitoring E. coli in surface water and wastewater and may be applicable to other bacteria."]},{"key":"dc:title","label":"Title","values":["Application of passive sampling for the monitoring of microbiological contaminants in aquatic systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Murphy, Heather"],"dc:creator":["Law, Ilya"],"dc:date.accessioned":["2024-01-11T20:27:21Z"],"dc:date.available":["2024-01-11T20:27:21Z"],"dc:date.copyright":["2023-12"],"dc:date.created":["2023-12-13"],"dc:description.abstract":["Traditional methods for monitoring pathogens in environmental waters have numerous drawbacks. In our systematic review, we found few studies that monitored bacteria in any water source using membrane filters as passive samplers. Therefore, to fill this data gap, we assessed the efficacy of passive sampling compared to composite sampling for the monitoring of E. coli onto membrane passive samplers over time. We observed similar rates for E. coli detections on passive samplers compared to composite samples in surface water and wastewater. We found significant linear accumulation of E. coli onto passive samplers throughout the entire 96 hours of deployment in surface water (R2 = 0.942; p = 0.001). In wastewater, passive samplers reached maximum concentration after 24 hours before plateauing. Passive sampling is an effective, low-cost, time-efficient, and practical method for monitoring E. coli in surface water and wastewater and may be applicable to other bacteria."],"dc:identifier.uri":["https://hdl.handle.net/10214/28098"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["passive samplers","membrane filters","E. coli","water quality monitoring","wastewater surveillance"],"dc:title":["Application of passive sampling for the monitoring of microbiological contaminants in aquatic systems"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Pathobiology"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Pathobiology"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:21:17Z"}