{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28181"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28181","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Air Lift Pump Performance Operating Under Three-phase Flow Conditions","abstract":"Solid particles introduction to airlift pumping system for mining applications has a remarkable impact on the multiphase flow behavior where additional forces due to solid presence will control pumping performance and efficiency. Further to these forces and in some cases depending on solid particles physical properties, concentration, and solubility, mixture physical rheology will be altered and the fluid dynamics will no longer behave as a Newtonian fluid. Despite of numerous experiments conducted to correlate measured results with constructed performance models, inconsistencies were noted when utilizing these models over a wide range of system applications due to variations in the experimental setups, different environmental conditions, and the exclusion of other critical controlling factors. This study explores the relevant trends and physics that can affect airlift systems performance under three-phase flow. An experimental setup simulating system application was designed, constructed, and tested under different Geometrical and Operational conditions, where three submergence ratios, solids of different physical properties, and two injector head designs at different air volumetric rates were evaluated. A system performance model was developed and evaluated using the current experimental results and correlated with experiments conducted by previous researchers. Solid particles deliverability increased at reduced particles size, and density and in particular at steady-state conditions. Higher submergence magnified the effect of particles physical properties on pumping system performance and results in early solid production accelerating the test cycle towards steady-state conditions, thus reducing the transition zone period which can cause pumping system failure. Performance enhancement was evident utilizing Swirl injector head over the Annular type only at lower submergence ratio under steady-state conditions.","abstract_html":"Solid particles introduction to airlift pumping system for mining applications has a remarkable impact on the multiphase flow behavior where additional forces due to solid presence will control pumping performance and efficiency. Further to these forces and in some cases depending on solid particles physical properties, concentration, and solubility, mixture physical rheology will be altered and the fluid dynamics will no longer behave as a Newtonian fluid. Despite of numerous experiments conducted to correlate measured results with constructed performance models, inconsistencies were noted when utilizing these models over a wide range of system applications due to variations in the experimental setups, different environmental conditions, and the exclusion of other critical controlling factors. This study explores the relevant trends and physics that can affect airlift systems performance under three-phase flow. An experimental setup simulating system application was designed, constructed, and tested under different Geometrical and Operational conditions, where three submergence ratios, solids of different physical properties, and two injector head designs at different air volumetric rates were evaluated. A system performance model was developed and evaluated using the current experimental results and correlated with experiments conducted by previous researchers. Solid particles deliverability increased at reduced particles size, and density and in particular at steady-state conditions. Higher submergence magnified the effect of particles physical properties on pumping system performance and results in early solid production accelerating the test cycle towards steady-state conditions, thus reducing the transition zone period which can cause pumping system failure. Performance enhancement was evident utilizing Swirl injector head over the Annular type only at lower submergence ratio under steady-state conditions.","abstract_has_math":false,"creators":["Taha, Marwan"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ahmed, Wael","Moussa, Soha Eid"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:24:21Z","subjects":["airlift pumps","three-phase flow","fluid dynamics"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28181","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28181","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2025-03-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F28181","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28181","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Wael","Moussa, Soha Eid"]},{"key":"dc:creator","label":"Author","values":["Taha, Marwan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-04-19T12:40:40Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024-03-15"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-03-15"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2025-03-15"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["airlift pumps","three-phase flow","fluid dynamics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28181"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Solid particles introduction to airlift pumping system for mining applications has a remarkable impact on the multiphase flow behavior where additional forces due to solid presence will control pumping performance and efficiency. Further to these forces and in some cases depending on solid particles physical properties, concentration, and solubility, mixture physical rheology will be altered and the fluid dynamics will no longer behave as a Newtonian fluid. Despite of numerous experiments conducted to correlate measured results with constructed performance models, inconsistencies were noted when utilizing these models over a wide range of system applications due to variations in the experimental setups, different environmental conditions, and the exclusion of other critical controlling factors. This study explores the relevant trends and physics that can affect airlift systems performance under three-phase flow. An experimental setup simulating system application was designed, constructed, and tested under different Geometrical and Operational conditions, where three submergence ratios, solids of different physical properties, and two injector head designs at different air volumetric rates were evaluated. A system performance model was developed and evaluated using the current experimental results and correlated with experiments conducted by previous researchers. Solid particles deliverability increased at reduced particles size, and density and in particular at steady-state conditions. Higher submergence magnified the effect of particles physical properties on pumping system performance and results in early solid production accelerating the test cycle towards steady-state conditions, thus reducing the transition zone period which can cause pumping system failure. Performance enhancement was evident utilizing Swirl injector head over the Annular type only at lower submergence ratio under steady-state conditions."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Ministry of Agriculture, Food and Rural Affairs","University of Guelph"]},{"key":"dc:title","label":"Title","values":["Air Lift Pump Performance Operating Under Three-phase Flow Conditions"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahmed, Wael","Moussa, Soha Eid"],"dc:creator":["Taha, Marwan"],"dc:date.accessioned":["2024-04-19T12:40:40Z"],"dc:date.copyright":["2024-03-15"],"dc:date.created":["2024-03-15"],"dc:date.embargo":["2025-03-15"],"dc:description.abstract":["Solid particles introduction to airlift pumping system for mining applications has a remarkable impact on the multiphase flow behavior where additional forces due to solid presence will control pumping performance and efficiency. Further to these forces and in some cases depending on solid particles physical properties, concentration, and solubility, mixture physical rheology will be altered and the fluid dynamics will no longer behave as a Newtonian fluid. Despite of numerous experiments conducted to correlate measured results with constructed performance models, inconsistencies were noted when utilizing these models over a wide range of system applications due to variations in the experimental setups, different environmental conditions, and the exclusion of other critical controlling factors. This study explores the relevant trends and physics that can affect airlift systems performance under three-phase flow. An experimental setup simulating system application was designed, constructed, and tested under different Geometrical and Operational conditions, where three submergence ratios, solids of different physical properties, and two injector head designs at different air volumetric rates were evaluated. A system performance model was developed and evaluated using the current experimental results and correlated with experiments conducted by previous researchers. Solid particles deliverability increased at reduced particles size, and density and in particular at steady-state conditions. Higher submergence magnified the effect of particles physical properties on pumping system performance and results in early solid production accelerating the test cycle towards steady-state conditions, thus reducing the transition zone period which can cause pumping system failure. Performance enhancement was evident utilizing Swirl injector head over the Annular type only at lower submergence ratio under steady-state conditions."],"dc:description.sponsorship":["Ontario Ministry of Agriculture, Food and Rural Affairs","University of Guelph"],"dc:identifier.uri":["https://hdl.handle.net/10214/28181"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["airlift pumps","three-phase flow","fluid dynamics"],"dc:title":["Air Lift Pump Performance Operating Under Three-phase Flow Conditions"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:21Z"}