{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28485"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28485","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Pseudo-Computed Tomography Image Generation from Magnetic Resonance Imaging Using Generative Adversarial Networks for Veterinary Radiation Therapy Planning","abstract":"The purpose of this research was to examine the feasibility of utilizing generative adversarial networks (GAN) to generate accurate pseudo-computed tomography (CT) images from magnetic resonance imaging (MRI) images for veterinary radiation therapy planning. This study used head standard CT images and T1 transverse with contrast 3-dimensional fast spoiled gradient-echo (FSPGR) head MRI images from 45 non-brachycephalic canines. A comparative study between two conditional GANs (CGAN), one with a U-Net generator and PatchGAN discriminator, and another with a ResNet U-Net generator and ResNet discriminator are compared. The ResNet U-Net generator and ResNet discriminator produced the most accurate pseudo-CT images with a mean absolute error of 109.54 ± 153.66 HU, a peak-signal-to-noise ratio of 21.15 ± 4.31 dB, and a dice similarity coefficient of 0.91 ± 0.12. A qualitative assessment by veterinary specialists revealed the most commonly assigned rank was “slightly similar” for both models.","abstract_html":"The purpose of this research was to examine the feasibility of utilizing generative adversarial networks (GAN) to generate accurate pseudo-computed tomography (CT) images from magnetic resonance imaging (MRI) images for veterinary radiation therapy planning. This study used head standard CT images and T1 transverse with contrast 3-dimensional fast spoiled gradient-echo (FSPGR) head MRI images from 45 non-brachycephalic canines. A comparative study between two conditional GANs (CGAN), one with a U-Net generator and PatchGAN discriminator, and another with a ResNet U-Net generator and ResNet discriminator are compared. The ResNet U-Net generator and ResNet discriminator produced the most accurate pseudo-CT images with a mean absolute error of 109.54 ± 153.66 HU, a peak-signal-to-noise ratio of 21.15 ± 4.31 dB, and a dice similarity coefficient of 0.91 ± 0.12. A qualitative assessment by veterinary specialists revealed the most commonly assigned rank was “slightly similar” for both models.","abstract_has_math":false,"creators":["Billings, Nicola"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ukwatta, Eranga"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-08-10","date_published":"2024-08-10","updated_at":"2026-11-19T08:25:31Z","subjects":["MRI","CT","deep learning","GAN","veterinary","radiation therapy"],"languages":["en"],"rights":["Attribution-NonCommercial 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28485","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28485","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F28485","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28485","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ukwatta, Eranga"]},{"key":"dc:creator","label":"Author","values":["Billings, Nicola"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-23T19:31:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-23T19:31:06Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024-08-12"]},{"key":"dc:date.issued","label":"Date","values":["2024-08-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MRI","CT","deep learning","GAN","veterinary","radiation therapy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28485"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this research was to examine the feasibility of utilizing generative adversarial networks (GAN) to generate accurate pseudo-computed tomography (CT) images from magnetic resonance imaging (MRI) images for veterinary radiation therapy planning. This study used head standard CT images and T1 transverse with contrast 3-dimensional fast spoiled gradient-echo (FSPGR) head MRI images from 45 non-brachycephalic canines. A comparative study between two conditional GANs (CGAN), one with a U-Net generator and PatchGAN discriminator, and another with a ResNet U-Net generator and ResNet discriminator are compared. The ResNet U-Net generator and ResNet discriminator produced the most accurate pseudo-CT images with a mean absolute error of 109.54 ± 153.66 HU, a peak-signal-to-noise ratio of 21.15 ± 4.31 dB, and a dice similarity coefficient of 0.91 ± 0.12. A qualitative assessment by veterinary specialists revealed the most commonly assigned rank was “slightly similar” for both models."]},{"key":"dc:title","label":"Title","values":["Pseudo-Computed Tomography Image Generation from Magnetic Resonance Imaging Using Generative Adversarial Networks for Veterinary Radiation Therapy Planning"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ukwatta, Eranga"],"dc:creator":["Billings, Nicola"],"dc:date.accessioned":["2024-08-23T19:31:06Z"],"dc:date.available":["2024-08-23T19:31:06Z"],"dc:date.copyright":["2024-08-12"],"dc:date.issued":["2024-08-10"],"dc:description.abstract":["The purpose of this research was to examine the feasibility of utilizing generative adversarial networks (GAN) to generate accurate pseudo-computed tomography (CT) images from magnetic resonance imaging (MRI) images for veterinary radiation therapy planning. This study used head standard CT images and T1 transverse with contrast 3-dimensional fast spoiled gradient-echo (FSPGR) head MRI images from 45 non-brachycephalic canines. A comparative study between two conditional GANs (CGAN), one with a U-Net generator and PatchGAN discriminator, and another with a ResNet U-Net generator and ResNet discriminator are compared. The ResNet U-Net generator and ResNet discriminator produced the most accurate pseudo-CT images with a mean absolute error of 109.54 ± 153.66 HU, a peak-signal-to-noise ratio of 21.15 ± 4.31 dB, and a dice similarity coefficient of 0.91 ± 0.12. A qualitative assessment by veterinary specialists revealed the most commonly assigned rank was “slightly similar” for both models."],"dc:identifier.uri":["https://hdl.handle.net/10214/28485"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc/4.0/"],"dc:subject":["MRI","CT","deep learning","GAN","veterinary","radiation therapy"],"dc:title":["Pseudo-Computed Tomography Image Generation from Magnetic Resonance Imaging Using Generative Adversarial Networks for Veterinary Radiation Therapy Planning"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:31Z"}