{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28620"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28620","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"The Biomechanics of Locking Plates used in a Supercutaneous Fashion","abstract":"Fracture fixation has progressed from perfect anatomic reduction to fracture stabilization preserving surrounding soft tissue. External fixators cause minimal soft tissue disruption during placement/removal. Despite these benefits, external fixators are bulky and costly leading to the investigation of alternatives. Locking plates, such as the string of pearls (SOP) and locking compression plate (LCP), gain strength from the screw-plate interface. Although soft tissue disruption is required for placement on the bone, precise contouring is not necessary. The present study compares the LCP and SOP placed 20mm off the bone surface to the external fixator. Constructs were tested in cyclic loading and compression to failure. The external fixator was statistically significantly stiffer (p=0.0050) than the LCP and SOP when placed supercutaneously. Additionally, the SOP was statistically stiffer than the LCP (p=0.0050). Thus, veterinary surgeons must carefully consider the implications of using locking in lieu of an external fixator.","abstract_html":"Fracture fixation has progressed from perfect anatomic reduction to fracture stabilization preserving surrounding soft tissue. External fixators cause minimal soft tissue disruption during placement/removal. Despite these benefits, external fixators are bulky and costly leading to the investigation of alternatives. Locking plates, such as the string of pearls (SOP) and locking compression plate (LCP), gain strength from the screw-plate interface. Although soft tissue disruption is required for placement on the bone, precise contouring is not necessary. The present study compares the LCP and SOP placed 20mm off the bone surface to the external fixator. Constructs were tested in cyclic loading and compression to failure. The external fixator was statistically significantly stiffer (p=0.0050) than the LCP and SOP when placed supercutaneously. Additionally, the SOP was statistically stiffer than the LCP (p=0.0050). Thus, veterinary surgeons must carefully consider the implications of using locking in lieu of an external fixator.","abstract_has_math":false,"creators":["Proctor, Ashley"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Clinical Studies","school":null,"contributors":[],"advisors":["MacIver, Melissa"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:22:15Z","subjects":["fracture fixation","locking plates","external fixators"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28620","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28620","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F28620","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28620","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["MacIver, Melissa"]},{"key":"dc:creator","label":"Author","values":["Proctor, Ashley"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-09-12T16:06:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-09-12T16:06:45Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024-09"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Clinical Studies"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Clinical Studies"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fracture fixation","locking plates","external fixators"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28620"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fracture fixation has progressed from perfect anatomic reduction to fracture stabilization preserving surrounding soft tissue. External fixators cause minimal soft tissue disruption during placement/removal. Despite these benefits, external fixators are bulky and costly leading to the investigation of alternatives. Locking plates, such as the string of pearls (SOP) and locking compression plate (LCP), gain strength from the screw-plate interface. Although soft tissue disruption is required for placement on the bone, precise contouring is not necessary. The present study compares the LCP and SOP placed 20mm off the bone surface to the external fixator. Constructs were tested in cyclic loading and compression to failure. The external fixator was statistically significantly stiffer (p=0.0050) than the LCP and SOP when placed supercutaneously. Additionally, the SOP was statistically stiffer than the LCP (p=0.0050). Thus, veterinary surgeons must carefully consider the implications of using locking in lieu of an external fixator."]},{"key":"dc:title","label":"Title","values":["The Biomechanics of Locking Plates used in a Supercutaneous Fashion"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["MacIver, Melissa"],"dc:creator":["Proctor, Ashley"],"dc:date.accessioned":["2024-09-12T16:06:45Z"],"dc:date.available":["2024-09-12T16:06:45Z"],"dc:date.copyright":["2024-09"],"dc:description.abstract":["Fracture fixation has progressed from perfect anatomic reduction to fracture stabilization preserving surrounding soft tissue. External fixators cause minimal soft tissue disruption during placement/removal. Despite these benefits, external fixators are bulky and costly leading to the investigation of alternatives. Locking plates, such as the string of pearls (SOP) and locking compression plate (LCP), gain strength from the screw-plate interface. Although soft tissue disruption is required for placement on the bone, precise contouring is not necessary. The present study compares the LCP and SOP placed 20mm off the bone surface to the external fixator. Constructs were tested in cyclic loading and compression to failure. The external fixator was statistically significantly stiffer (p=0.0050) than the LCP and SOP when placed supercutaneously. Additionally, the SOP was statistically stiffer than the LCP (p=0.0050). Thus, veterinary surgeons must carefully consider the implications of using locking in lieu of an external fixator."],"dc:identifier.uri":["https://hdl.handle.net/10214/28620"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["fracture fixation","locking plates","external fixators"],"dc:title":["The Biomechanics of Locking Plates used in a Supercutaneous Fashion"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Clinical Studies"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Clinical Studies"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:15Z"}