{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28816"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28816","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Characterization Of Milking Centre Wash Water For Treatment Feasibility Using On-Site Septic Systems","abstract":"Ontario dairy farm wash water consists of the resulting water from washing the pipelines after milking is complete. The washing cycle consists of four separate rinses including a pre-rinse, detergent rinse, acid rinse, and a sanitize rinse. This wash water contains many organic and inorganic constituents that must be handled properly according to Ontario legislation. A septic system is a common treatment option for dairy farms; however, issues have risen with on-site treatment due to inconsistent wording within Ontario legislation. This work investigates the potential use of onsite systems to treat milking center wash water and declare any contraventions between the legislations. After a thorough investigation, it is recommended to use an air rinse prior to the wash before the wash water enters a septic system. The air rinse reduces the organic contaminates, chemical oxygen demand and total suspended solids, by an average of about 73% and 81%, respectively.","abstract_html":"Ontario dairy farm wash water consists of the resulting water from washing the pipelines after milking is complete. The washing cycle consists of four separate rinses including a pre-rinse, detergent rinse, acid rinse, and a sanitize rinse. This wash water contains many organic and inorganic constituents that must be handled properly according to Ontario legislation. A septic system is a common treatment option for dairy farms; however, issues have risen with on-site treatment due to inconsistent wording within Ontario legislation. This work investigates the potential use of onsite systems to treat milking center wash water and declare any contraventions between the legislations. After a thorough investigation, it is recommended to use an air rinse prior to the wash before the wash water enters a septic system. The air rinse reduces the organic contaminates, chemical oxygen demand and total suspended solids, by an average of about 73% and 81%, respectively.","abstract_has_math":false,"creators":["Figliuzzi, Tyler"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Abbassi, Bassim"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-01-06","date_published":"2025-01-06","updated_at":"2026-11-19T08:27:45Z","subjects":["dairy wash water treatment","chemical oxygen demand","biological oxygen demand","total suspended solids","septic systems"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28816","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28816","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F28816","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28816","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abbassi, Bassim"]},{"key":"dc:creator","label":"Author","values":["Figliuzzi, Tyler"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-09T15:26:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-09T15:26:02Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-01"]},{"key":"dc:date.issued","label":"Date","values":["2025-01-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dairy wash water treatment","chemical oxygen demand","biological oxygen demand","total suspended solids","septic systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28816"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ontario dairy farm wash water consists of the resulting water from washing the pipelines after milking is complete. The washing cycle consists of four separate rinses including a pre-rinse, detergent rinse, acid rinse, and a sanitize rinse. This wash water contains many organic and inorganic constituents that must be handled properly according to Ontario legislation. A septic system is a common treatment option for dairy farms; however, issues have risen with on-site treatment due to inconsistent wording within Ontario legislation. This work investigates the potential use of onsite systems to treat milking center wash water and declare any contraventions between the legislations. After a thorough investigation, it is recommended to use an air rinse prior to the wash before the wash water enters a septic system. The air rinse reduces the organic contaminates, chemical oxygen demand and total suspended solids, by an average of about 73% and 81%, respectively."]},{"key":"dc:title","label":"Title","values":["Characterization Of Milking Centre Wash Water For Treatment Feasibility Using On-Site Septic Systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abbassi, Bassim"],"dc:creator":["Figliuzzi, Tyler"],"dc:date.accessioned":["2025-01-09T15:26:02Z"],"dc:date.available":["2025-01-09T15:26:02Z"],"dc:date.copyright":["2025-01"],"dc:date.issued":["2025-01-06"],"dc:description.abstract":["Ontario dairy farm wash water consists of the resulting water from washing the pipelines after milking is complete. The washing cycle consists of four separate rinses including a pre-rinse, detergent rinse, acid rinse, and a sanitize rinse. This wash water contains many organic and inorganic constituents that must be handled properly according to Ontario legislation. A septic system is a common treatment option for dairy farms; however, issues have risen with on-site treatment due to inconsistent wording within Ontario legislation. This work investigates the potential use of onsite systems to treat milking center wash water and declare any contraventions between the legislations. After a thorough investigation, it is recommended to use an air rinse prior to the wash before the wash water enters a septic system. The air rinse reduces the organic contaminates, chemical oxygen demand and total suspended solids, by an average of about 73% and 81%, respectively."],"dc:identifier.uri":["https://hdl.handle.net/10214/28816"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["dairy wash water treatment","chemical oxygen demand","biological oxygen demand","total suspended solids","septic systems"],"dc:title":["Characterization Of Milking Centre Wash Water For Treatment Feasibility Using On-Site Septic Systems"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:45Z"}