{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/28937"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/28937","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Evaluation of Ultrasonography for Diagnosis of Postpartum Reproductive Tract Disease in Dairy Cows","abstract":"This thesis aimed to identify ultrasonographic criteria to diagnose postpartum purulent vaginal discharge (PVD) or endometritis (ENDO) at 22 to 28 days post-partum, using Metricheck and cytology as reference tests, respectively. The prevalence of PVD and ENDO at week four after calving was 21.4% and 29%, respectively. Distended lumen shape (> 20 mm) and cervical diameter ≥ 4 cm were associated with PVD, while presence of fluid and cervical diameter ≥ 4 cm were associated with ENDO. Cows with larger volume of intraluminal fluid had greater odds of being diagnosed with endometritis. No ultrasonography parameters were associated with diagnosis of subclinical endometritis. When tests were assessed in parallel, ultrasonography showed 37% sensitivity and 83% specificity for PVD, and 74% sensitivity with 36% specificity for ENDO. This thesis suggests that ultrasonography could be a useful to help identify cows unlikely to have PVD, but it is not accurate for diagnosing PVD or ENDO.","abstract_html":"This thesis aimed to identify ultrasonographic criteria to diagnose postpartum purulent vaginal discharge (PVD) or endometritis (ENDO) at 22 to 28 days post-partum, using Metricheck and cytology as reference tests, respectively. The prevalence of PVD and ENDO at week four after calving was 21.4% and 29%, respectively. Distended lumen shape (&gt; 20 mm) and cervical diameter ≥ 4 cm were associated with PVD, while presence of fluid and cervical diameter ≥ 4 cm were associated with ENDO. Cows with larger volume of intraluminal fluid had greater odds of being diagnosed with endometritis. No ultrasonography parameters were associated with diagnosis of subclinical endometritis. When tests were assessed in parallel, ultrasonography showed 37% sensitivity and 83% specificity for PVD, and 74% sensitivity with 36% specificity for ENDO. This thesis suggests that ultrasonography could be a useful to help identify cows unlikely to have PVD, but it is not accurate for diagnosing PVD or ENDO.","abstract_has_math":false,"creators":["Malet, Rocio"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Dairy at Guelph","school":null,"contributors":[],"advisors":["LeBlanc, Stephen J."],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:40Z","subjects":["ultrasonography","purulent vaginal discharge","endometritis"],"languages":["en"],"rights":["Attribution-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/28937","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/28937","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F28937","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F28937","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["LeBlanc, Stephen J."]},{"key":"dc:creator","label":"Author","values":["Malet, Rocio"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-23T15:00:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-23T15:00:29Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-02-20"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Dairy at Guelph"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Population Medicine"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ultrasonography","purulent vaginal discharge","endometritis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/28937"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis aimed to identify ultrasonographic criteria to diagnose postpartum purulent vaginal discharge (PVD) or endometritis (ENDO) at 22 to 28 days post-partum, using Metricheck and cytology as reference tests, respectively. The prevalence of PVD and ENDO at week four after calving was 21.4% and 29%, respectively. Distended lumen shape (> 20 mm) and cervical diameter ≥ 4 cm were associated with PVD, while presence of fluid and cervical diameter ≥ 4 cm were associated with ENDO. Cows with larger volume of intraluminal fluid had greater odds of being diagnosed with endometritis. No ultrasonography parameters were associated with diagnosis of subclinical endometritis. When tests were assessed in parallel, ultrasonography showed 37% sensitivity and 83% specificity for PVD, and 74% sensitivity with 36% specificity for ENDO. This thesis suggests that ultrasonography could be a useful to help identify cows unlikely to have PVD, but it is not accurate for diagnosing PVD or ENDO."]},{"key":"dc:title","label":"Title","values":["Evaluation of Ultrasonography for Diagnosis of Postpartum Reproductive Tract Disease in Dairy Cows"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["LeBlanc, Stephen J."],"dc:creator":["Malet, Rocio"],"dc:date.accessioned":["2025-04-23T15:00:29Z"],"dc:date.available":["2025-04-23T15:00:29Z"],"dc:date.copyright":["2025-02-20"],"dc:description.abstract":["This thesis aimed to identify ultrasonographic criteria to diagnose postpartum purulent vaginal discharge (PVD) or endometritis (ENDO) at 22 to 28 days post-partum, using Metricheck and cytology as reference tests, respectively. The prevalence of PVD and ENDO at week four after calving was 21.4% and 29%, respectively. Distended lumen shape (> 20 mm) and cervical diameter ≥ 4 cm were associated with PVD, while presence of fluid and cervical diameter ≥ 4 cm were associated with ENDO. Cows with larger volume of intraluminal fluid had greater odds of being diagnosed with endometritis. No ultrasonography parameters were associated with diagnosis of subclinical endometritis. When tests were assessed in parallel, ultrasonography showed 37% sensitivity and 83% specificity for PVD, and 74% sensitivity with 36% specificity for ENDO. This thesis suggests that ultrasonography could be a useful to help identify cows unlikely to have PVD, but it is not accurate for diagnosing PVD or ENDO."],"dc:identifier.uri":["https://hdl.handle.net/10214/28937"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nd/4.0/"],"dc:subject":["ultrasonography","purulent vaginal discharge","endometritis"],"dc:title":["Evaluation of Ultrasonography for Diagnosis of Postpartum Reproductive Tract Disease in Dairy Cows"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Dairy at Guelph"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Population Medicine"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:40Z"}