{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29206"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29206","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Head-Controlled Interface for Human Assistive Robotic Devices","abstract":"This thesis proposes a camera-based, head-controlled interface for a 6-DoF robotic arm, designed to help individuals with upper-limb impairments. This system avoids traditional interfaces like joysticks or voice commands that may exclude some users. The platform integrates various modules, including a YOLOv9-Seg network for object detection, a MediaPipe-driven facial landmark node for head gestures, a ROS-based graph navigator, and a mouth-open gesture for selection confirmation. A quick-release tool mount ensures continuous alignment between the camera and the robotic arm. An assistive-feeding task was developed as a proof-of-concept. In tests with 22 able-bodied volunteers, the system's vision and head-gesture interfaces proved highly accurate and reliable. Participants rated the system highly for safety and comfort. These results confirm that a low-cost camera and CPU-based neural network can provide real-time, fatigue-free head control. The modular design can be repurposed for various tasks, like grooming or medication dispensing, broadening the accessibility of assistive robotics.","abstract_html":"This thesis proposes a camera-based, head-controlled interface for a 6-DoF robotic arm, designed to help individuals with upper-limb impairments. This system avoids traditional interfaces like joysticks or voice commands that may exclude some users. The platform integrates various modules, including a YOLOv9-Seg network for object detection, a MediaPipe-driven facial landmark node for head gestures, a ROS-based graph navigator, and a mouth-open gesture for selection confirmation. A quick-release tool mount ensures continuous alignment between the camera and the robotic arm. An assistive-feeding task was developed as a proof-of-concept. In tests with 22 able-bodied volunteers, the system&#x27;s vision and head-gesture interfaces proved highly accurate and reliable. Participants rated the system highly for safety and comfort. These results confirm that a low-cost camera and CPU-based neural network can provide real-time, fatigue-free head control. The modular design can be repurposed for various tasks, like grooming or medication dispensing, broadening the accessibility of assistive robotics.","abstract_has_math":false,"creators":["Ghulam, Zeyad"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Abdullah, Hussein"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:24:49Z","subjects":["human-robotic interaction","assistive technologies","head tracking interface","artificial intelligence","accessibility"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29206","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29206","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F29206","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29206","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abdullah, Hussein"]},{"key":"dc:creator","label":"Author","values":["Ghulam, Zeyad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-05T13:37:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-09-05T13:37:13Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["human-robotic interaction","assistive technologies","head tracking interface","artificial intelligence","accessibility"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29206"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis proposes a camera-based, head-controlled interface for a 6-DoF robotic arm, designed to help individuals with upper-limb impairments. This system avoids traditional interfaces like joysticks or voice commands that may exclude some users. The platform integrates various modules, including a YOLOv9-Seg network for object detection, a MediaPipe-driven facial landmark node for head gestures, a ROS-based graph navigator, and a mouth-open gesture for selection confirmation. A quick-release tool mount ensures continuous alignment between the camera and the robotic arm. An assistive-feeding task was developed as a proof-of-concept. In tests with 22 able-bodied volunteers, the system's vision and head-gesture interfaces proved highly accurate and reliable. Participants rated the system highly for safety and comfort. These results confirm that a low-cost camera and CPU-based neural network can provide real-time, fatigue-free head control. The modular design can be repurposed for various tasks, like grooming or medication dispensing, broadening the accessibility of assistive robotics."]},{"key":"dc:title","label":"Title","values":["Head-Controlled Interface for Human Assistive Robotic Devices"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abdullah, Hussein"],"dc:creator":["Ghulam, Zeyad"],"dc:date.accessioned":["2025-09-05T13:37:13Z"],"dc:date.available":["2025-09-05T13:37:13Z"],"dc:date.copyright":["2025-08"],"dc:description.abstract":["This thesis proposes a camera-based, head-controlled interface for a 6-DoF robotic arm, designed to help individuals with upper-limb impairments. This system avoids traditional interfaces like joysticks or voice commands that may exclude some users. The platform integrates various modules, including a YOLOv9-Seg network for object detection, a MediaPipe-driven facial landmark node for head gestures, a ROS-based graph navigator, and a mouth-open gesture for selection confirmation. A quick-release tool mount ensures continuous alignment between the camera and the robotic arm. An assistive-feeding task was developed as a proof-of-concept. In tests with 22 able-bodied volunteers, the system's vision and head-gesture interfaces proved highly accurate and reliable. Participants rated the system highly for safety and comfort. These results confirm that a low-cost camera and CPU-based neural network can provide real-time, fatigue-free head control. The modular design can be repurposed for various tasks, like grooming or medication dispensing, broadening the accessibility of assistive robotics."],"dc:identifier.uri":["https://hdl.handle.net/10214/29206"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["human-robotic interaction","assistive technologies","head tracking interface","artificial intelligence","accessibility"],"dc:title":["Head-Controlled Interface for Human Assistive Robotic Devices"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:49Z"}