{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29273"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29273","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Electrochemical sensing of pharmaceutical compounds in biological matrices based on the Molecular Imprinted Polymers","abstract":"This thesis aimed to develop electrochemical sensors for the determination of pharmaceutical compounds in biological matrices as a cost-effective, rapid, and environmentally compatible alternative to conventional chromatographic methods. In the first project, a molecularly imprinted polymer (MIP) was synthesized for Penicillin G (PNCG) and incorporated into a carbon paste electrode (CPE) to fabricate a CPE-MIP sensor. The sensor was characterized and tested in human plasma, demonstrating reproducibility, repeatability, selectivity, stability, minimal matrix effects, and satisfactory recovery. Two linear ranges were observed (5.0 × 10⁻⁸ – 1.0 × 10⁻⁶ M and 1.0 × 10⁻⁶ – 1.0 × 10⁻⁴ M) with a detection limit of 3.8 × 10⁻⁸ M, confirming its effectiveness for PNCG detection. During the second project, this approach was extended to Flutamide (FLT), an anti-cancer drug requiring precise therapeutic monitoring. A CPE-MIP sensor was systematically optimized and validated according to clinical guidelines. The sensor exhibited strong selectivity, reproducibility, and stability when tested in plasma, with a linear range of 0.1 – 20 nM and a detection limit of 0.073 nM. Compared with chromatographic techniques, the proposed sensor offered notable advantages in simplicity, cost, and rapid response, highlighting its potential for clinical applications. In the third project, a dual molecularly imprinted polymer (DMIP) sensor was developed to enable the simultaneous detection of Tenofovir (TNF) and Diclofenac (DFN) in plasma, addressing concerns about drug–drug interactions and kidney risks. The DMIP-modified CPE was validated for sensitivity, recovery, matrix effects, repeatability, and stability, demonstrating linear ranges of 1 – 100 nM and detection limits of 0.22 nM (DFN) and 0.25 nM (TNF). The sensor exhibited high reproducibility, reliability, and analytical performance compared to conventional methods. Overall, this PhD work has demonstrated the feasibility of MIP- and DMIP-based electrochemical sensors as promising alternatives to chromatography for pharmaceutical monitoring in clinical and biomedical applications.","abstract_html":"This thesis aimed to develop electrochemical sensors for the determination of pharmaceutical compounds in biological matrices as a cost-effective, rapid, and environmentally compatible alternative to conventional chromatographic methods. In the first project, a molecularly imprinted polymer (MIP) was synthesized for Penicillin G (PNCG) and incorporated into a carbon paste electrode (CPE) to fabricate a CPE-MIP sensor. The sensor was characterized and tested in human plasma, demonstrating reproducibility, repeatability, selectivity, stability, minimal matrix effects, and satisfactory recovery. Two linear ranges were observed (5.0 × 10⁻⁸ – 1.0 × 10⁻⁶ M and 1.0 × 10⁻⁶ – 1.0 × 10⁻⁴ M) with a detection limit of 3.8 × 10⁻⁸ M, confirming its effectiveness for PNCG detection. During the second project, this approach was extended to Flutamide (FLT), an anti-cancer drug requiring precise therapeutic monitoring. A CPE-MIP sensor was systematically optimized and validated according to clinical guidelines. The sensor exhibited strong selectivity, reproducibility, and stability when tested in plasma, with a linear range of 0.1 – 20 nM and a detection limit of 0.073 nM. Compared with chromatographic techniques, the proposed sensor offered notable advantages in simplicity, cost, and rapid response, highlighting its potential for clinical applications. In the third project, a dual molecularly imprinted polymer (DMIP) sensor was developed to enable the simultaneous detection of Tenofovir (TNF) and Diclofenac (DFN) in plasma, addressing concerns about drug–drug interactions and kidney risks. The DMIP-modified CPE was validated for sensitivity, recovery, matrix effects, repeatability, and stability, demonstrating linear ranges of 1 – 100 nM and detection limits of 0.22 nM (DFN) and 0.25 nM (TNF). The sensor exhibited high reproducibility, reliability, and analytical performance compared to conventional methods. Overall, this PhD work has demonstrated the feasibility of MIP- and DMIP-based electrochemical sensors as promising alternatives to chromatography for pharmaceutical monitoring in clinical and biomedical applications.","abstract_has_math":false,"creators":["Tavana, Babak"],"institution":"University of Guelph","degree_name":"Doctor of Philosophy","degree_level":null,"degree_discipline":null,"degree_department":"Department of Chemistry","school":null,"contributors":[],"advisors":["Chen, Aicheng"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:34Z","subjects":["electrochemical sensor","pharmaceutical compounds","molecular imprinted polymer","biological matrices","human blood plasma"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Tavana, B., Ramirez, C.A., Chen, A. (2025). Electrochemical determination of Penicillin G in biological matrix based on the carbon paste electrode modified with a molecular imprinted polymer.Microchemical Journal 2025, 209, 112827; https://doi.org/10.1016/j.microc.2025.112827","Tavana, B., & Chen, A. (2022). Determination of Drugs in Clinical Trials: Current Status and Outlook. Sensors, 22(4), 1592. https://doi.org/10.3390/s22041592"],"render_values":[{"text":"Tavana, B., Ramirez, C.A., Chen, A. (2025). Electrochemical determination of Penicillin G in biological matrix based on the carbon paste electrode modified with a molecular imprinted polymer.Microchemical Journal 2025, 209, 112827; https://doi.org/10.1016/j.microc.2025.112827","href":"https://doi.org/10.1016/j.microc.2025.112827","code":true},{"text":"Tavana, B., & Chen, A. (2022). Determination of Drugs in Clinical Trials: Current Status and Outlook. Sensors, 22(4), 1592. https://doi.org/10.3390/s22041592","href":"https://doi.org/10.3390/s22041592","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29273","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29273","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2026-07-14","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F29273","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29273","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chen, Aicheng"]},{"key":"dc:creator","label":"Author","values":["Tavana, Babak"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-11T13:11:19Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-09"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-07-14"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Chemistry"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electrochemical sensor","pharmaceutical compounds","molecular imprinted polymer","biological matrices","human blood plasma"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Tavana, B., Ramirez, C.A., Chen, A. (2025). Electrochemical determination of Penicillin G in biological matrix based on the carbon paste electrode modified with a molecular imprinted polymer.Microchemical Journal 2025, 209, 112827; https://doi.org/10.1016/j.microc.2025.112827","Tavana, B., & Chen, A. (2022). Determination of Drugs in Clinical Trials: Current Status and Outlook. Sensors, 22(4), 1592. https://doi.org/10.3390/s22041592"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29273"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis aimed to develop electrochemical sensors for the determination of pharmaceutical compounds in biological matrices as a cost-effective, rapid, and environmentally compatible alternative to conventional chromatographic methods. In the first project, a molecularly imprinted polymer (MIP) was synthesized for Penicillin G (PNCG) and incorporated into a carbon paste electrode (CPE) to fabricate a CPE-MIP sensor. The sensor was characterized and tested in human plasma, demonstrating reproducibility, repeatability, selectivity, stability, minimal matrix effects, and satisfactory recovery. Two linear ranges were observed (5.0 × 10⁻⁸ – 1.0 × 10⁻⁶ M and 1.0 × 10⁻⁶ – 1.0 × 10⁻⁴ M) with a detection limit of 3.8 × 10⁻⁸ M, confirming its effectiveness for PNCG detection. During the second project, this approach was extended to Flutamide (FLT), an anti-cancer drug requiring precise therapeutic monitoring. A CPE-MIP sensor was systematically optimized and validated according to clinical guidelines. The sensor exhibited strong selectivity, reproducibility, and stability when tested in plasma, with a linear range of 0.1 – 20 nM and a detection limit of 0.073 nM. Compared with chromatographic techniques, the proposed sensor offered notable advantages in simplicity, cost, and rapid response, highlighting its potential for clinical applications. In the third project, a dual molecularly imprinted polymer (DMIP) sensor was developed to enable the simultaneous detection of Tenofovir (TNF) and Diclofenac (DFN) in plasma, addressing concerns about drug–drug interactions and kidney risks. The DMIP-modified CPE was validated for sensitivity, recovery, matrix effects, repeatability, and stability, demonstrating linear ranges of 1 – 100 nM and detection limits of 0.22 nM (DFN) and 0.25 nM (TNF). The sensor exhibited high reproducibility, reliability, and analytical performance compared to conventional methods. Overall, this PhD work has demonstrated the feasibility of MIP- and DMIP-based electrochemical sensors as promising alternatives to chromatography for pharmaceutical monitoring in clinical and biomedical applications."]},{"key":"dc:title","label":"Title","values":["Electrochemical sensing of pharmaceutical compounds in biological matrices based on the Molecular Imprinted Polymers"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chen, Aicheng"],"dc:creator":["Tavana, Babak"],"dc:date.accessioned":["2025-09-11T13:11:19Z"],"dc:date.copyright":["2025-09"],"dc:date.embargo":["2026-07-14"],"dc:description.abstract":["This thesis aimed to develop electrochemical sensors for the determination of pharmaceutical compounds in biological matrices as a cost-effective, rapid, and environmentally compatible alternative to conventional chromatographic methods. In the first project, a molecularly imprinted polymer (MIP) was synthesized for Penicillin G (PNCG) and incorporated into a carbon paste electrode (CPE) to fabricate a CPE-MIP sensor. The sensor was characterized and tested in human plasma, demonstrating reproducibility, repeatability, selectivity, stability, minimal matrix effects, and satisfactory recovery. Two linear ranges were observed (5.0 × 10⁻⁸ – 1.0 × 10⁻⁶ M and 1.0 × 10⁻⁶ – 1.0 × 10⁻⁴ M) with a detection limit of 3.8 × 10⁻⁸ M, confirming its effectiveness for PNCG detection. During the second project, this approach was extended to Flutamide (FLT), an anti-cancer drug requiring precise therapeutic monitoring. A CPE-MIP sensor was systematically optimized and validated according to clinical guidelines. The sensor exhibited strong selectivity, reproducibility, and stability when tested in plasma, with a linear range of 0.1 – 20 nM and a detection limit of 0.073 nM. Compared with chromatographic techniques, the proposed sensor offered notable advantages in simplicity, cost, and rapid response, highlighting its potential for clinical applications. In the third project, a dual molecularly imprinted polymer (DMIP) sensor was developed to enable the simultaneous detection of Tenofovir (TNF) and Diclofenac (DFN) in plasma, addressing concerns about drug–drug interactions and kidney risks. The DMIP-modified CPE was validated for sensitivity, recovery, matrix effects, repeatability, and stability, demonstrating linear ranges of 1 – 100 nM and detection limits of 0.22 nM (DFN) and 0.25 nM (TNF). The sensor exhibited high reproducibility, reliability, and analytical performance compared to conventional methods. Overall, this PhD work has demonstrated the feasibility of MIP- and DMIP-based electrochemical sensors as promising alternatives to chromatography for pharmaceutical monitoring in clinical and biomedical applications."],"dc:identifier.citation":["Tavana, B., Ramirez, C.A., Chen, A. (2025). Electrochemical determination of Penicillin G in biological matrix based on the carbon paste electrode modified with a molecular imprinted polymer.Microchemical Journal 2025, 209, 112827; https://doi.org/10.1016/j.microc.2025.112827","Tavana, B., & Chen, A. (2022). Determination of Drugs in Clinical Trials: Current Status and Outlook. Sensors, 22(4), 1592. https://doi.org/10.3390/s22041592"],"dc:identifier.uri":["https://hdl.handle.net/10214/29273"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["electrochemical sensor","pharmaceutical compounds","molecular imprinted polymer","biological matrices","human blood plasma"],"dc:title":["Electrochemical sensing of pharmaceutical compounds in biological matrices based on the Molecular Imprinted Polymers"],"dc:type":["Thesis"],"others:access_status":["embargo"],"thesis:degree_department":["Department of Chemistry"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:degree_program":["Chemistry"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:34Z"}