{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29328"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29328","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Influence of Cerium on the Mechanical and Corrosion Properties of Mg-Zn-Ca Alloys for Biomedical Implants","abstract":"Temporary orthopedic implants require alloys with high biocompatibility, mechanical strength, and controlled degradation. Magnesium alloys with 1 and 4 wt.% zinc, 0.25 wt.% calcium, and 0.1, 0.2, and 0.5 wt.% cerium were cast and characterized using compression, microhardness, x-ray diffraction, differential scanning calorimetry, microscopy, and hydrogen evolution testing. The Ar+R-134a and Ar+R-1234yf cover gases improved surface melt protection. Alloys containing higher zinc formed MgZn2 and Ca2Mg6Zn3 phases, while higher cerium promoted T-(MgZn)12Ce phase formation. The Mg-4Zn-0.25Ca-0.1Ce alloy exhibited high tensile (approximately 352 MPa) and yield (approximately 265 MPa) strengths. Pure magnesium dip coated in graphene nanoparticles/polymer hybrid layers revealed uniform coatings and reduced weight loss in Ringer’s solution. Corrosion and hardness results illustrated the Mg-1Zn-0.25Ca-0.2Ce alloy having low weight loss and high microhardness. Overall, Mg-Zn-Ca-Ce alloys demonstrate good corrosion resistance and strength, supporting their potential for use in temporary orthopedic implants.","abstract_html":"Temporary orthopedic implants require alloys with high biocompatibility, mechanical strength, and controlled degradation. Magnesium alloys with 1 and 4 wt.% zinc, 0.25 wt.% calcium, and 0.1, 0.2, and 0.5 wt.% cerium were cast and characterized using compression, microhardness, x-ray diffraction, differential scanning calorimetry, microscopy, and hydrogen evolution testing. The Ar+R-134a and Ar+R-1234yf cover gases improved surface melt protection. Alloys containing higher zinc formed MgZn2 and Ca2Mg6Zn3 phases, while higher cerium promoted T-(MgZn)12Ce phase formation. The Mg-4Zn-0.25Ca-0.1Ce alloy exhibited high tensile (approximately 352 MPa) and yield (approximately 265 MPa) strengths. Pure magnesium dip coated in graphene nanoparticles/polymer hybrid layers revealed uniform coatings and reduced weight loss in Ringer’s solution. Corrosion and hardness results illustrated the Mg-1Zn-0.25Ca-0.2Ce alloy having low weight loss and high microhardness. Overall, Mg-Zn-Ca-Ce alloys demonstrate good corrosion resistance and strength, supporting their potential for use in temporary orthopedic implants.","abstract_has_math":false,"creators":["Humeniuc, Daria"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Elsayed, Abdallah"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:22:03Z","subjects":["Mg biomedical implants","Corrosion resistance","Mg-Zn-Ca-Ce alloys","Polymer coatings","Cover gases","XRD patterns","DSC curves","SEM and EDS","Compression testing","Orthopedic implants"],"languages":["en"],"rights":["Attribution-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29328","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29328","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2026-09-04","access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29328","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Elsayed, Abdallah"]},{"key":"dc:creator","label":"Author","values":["Humeniuc, Daria"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-12T17:34:33Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-09"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-09-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mg biomedical implants","Corrosion resistance","Mg-Zn-Ca-Ce alloys","Polymer coatings","Cover gases","XRD patterns","DSC curves","SEM and EDS","Compression testing","Orthopedic implants"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29328"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Temporary orthopedic implants require alloys with high biocompatibility, mechanical strength, and controlled degradation. Magnesium alloys with 1 and 4 wt.% zinc, 0.25 wt.% calcium, and 0.1, 0.2, and 0.5 wt.% cerium were cast and characterized using compression, microhardness, x-ray diffraction, differential scanning calorimetry, microscopy, and hydrogen evolution testing. The Ar+R-134a and Ar+R-1234yf cover gases improved surface melt protection. Alloys containing higher zinc formed MgZn2 and Ca2Mg6Zn3 phases, while higher cerium promoted T-(MgZn)12Ce phase formation. The Mg-4Zn-0.25Ca-0.1Ce alloy exhibited high tensile (approximately 352 MPa) and yield (approximately 265 MPa) strengths. Pure magnesium dip coated in graphene nanoparticles/polymer hybrid layers revealed uniform coatings and reduced weight loss in Ringer’s solution. Corrosion and hardness results illustrated the Mg-1Zn-0.25Ca-0.2Ce alloy having low weight loss and high microhardness. Overall, Mg-Zn-Ca-Ce alloys demonstrate good corrosion resistance and strength, supporting their potential for use in temporary orthopedic implants."]},{"key":"dc:title","label":"Title","values":["Influence of Cerium on the Mechanical and Corrosion Properties of Mg-Zn-Ca Alloys for Biomedical Implants"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Elsayed, Abdallah"],"dc:creator":["Humeniuc, Daria"],"dc:date.accessioned":["2025-09-12T17:34:33Z"],"dc:date.copyright":["2025-09"],"dc:date.embargo":["2026-09-04"],"dc:description.abstract":["Temporary orthopedic implants require alloys with high biocompatibility, mechanical strength, and controlled degradation. Magnesium alloys with 1 and 4 wt.% zinc, 0.25 wt.% calcium, and 0.1, 0.2, and 0.5 wt.% cerium were cast and characterized using compression, microhardness, x-ray diffraction, differential scanning calorimetry, microscopy, and hydrogen evolution testing. The Ar+R-134a and Ar+R-1234yf cover gases improved surface melt protection. Alloys containing higher zinc formed MgZn2 and Ca2Mg6Zn3 phases, while higher cerium promoted T-(MgZn)12Ce phase formation. The Mg-4Zn-0.25Ca-0.1Ce alloy exhibited high tensile (approximately 352 MPa) and yield (approximately 265 MPa) strengths. Pure magnesium dip coated in graphene nanoparticles/polymer hybrid layers revealed uniform coatings and reduced weight loss in Ringer’s solution. Corrosion and hardness results illustrated the Mg-1Zn-0.25Ca-0.2Ce alloy having low weight loss and high microhardness. Overall, Mg-Zn-Ca-Ce alloys demonstrate good corrosion resistance and strength, supporting their potential for use in temporary orthopedic implants."],"dc:identifier.uri":["https://hdl.handle.net/10214/29328"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nd/4.0/"],"dc:subject":["Mg biomedical implants","Corrosion resistance","Mg-Zn-Ca-Ce alloys","Polymer coatings","Cover gases","XRD patterns","DSC curves","SEM and EDS","Compression testing","Orthopedic implants"],"dc:title":["Influence of Cerium on the Mechanical and Corrosion Properties of Mg-Zn-Ca Alloys for Biomedical Implants"],"dc:type":["Thesis"],"others:access_status":["embargo"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:03Z"}