{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29358"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29358","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Optimizing in Vitro Motility Assays for High-Throughput Analysis of Actin-Myosin Dynamics and Drug Screening","abstract":"Cardiomyopathies present significant therapeutic challenges due to their genetic heterogeneity and lack of targeted treatments. The actomyosin in vitro motility (IVM) assay is a gold-standard method for studying sarcomere protein interactions; however, its traditional flow-cell format limits throughput. This research aims to adapt the IVM assay into a high-throughput format for drug screening and mechanistic analysis. A custom 96-well plate compatible with nitrocellulose-coated coverslips was developed and paired with automated imaging on a Nikon Eclipse Ti2-e. An optimized analysis pipeline using TrackMate software enabled automated filament tracking, with maximum velocity output closely matching manual tracking metrics. Validation demonstrated no significant difference in Vmax between coverslip and well-plate assays. This high-throughput IVM platform improves assay scalability and reproducibility, providing a valuable tool for screening cardiomyopathy therapies and characterizing actomyosin dynamics under diverse conditions.","abstract_html":"Cardiomyopathies present significant therapeutic challenges due to their genetic heterogeneity and lack of targeted treatments. The actomyosin in vitro motility (IVM) assay is a gold-standard method for studying sarcomere protein interactions; however, its traditional flow-cell format limits throughput. This research aims to adapt the IVM assay into a high-throughput format for drug screening and mechanistic analysis. A custom 96-well plate compatible with nitrocellulose-coated coverslips was developed and paired with automated imaging on a Nikon Eclipse Ti2-e. An optimized analysis pipeline using TrackMate software enabled automated filament tracking, with maximum velocity output closely matching manual tracking metrics. Validation demonstrated no significant difference in Vmax between coverslip and well-plate assays. This high-throughput IVM platform improves assay scalability and reproducibility, providing a valuable tool for screening cardiomyopathy therapies and characterizing actomyosin dynamics under diverse conditions.","abstract_has_math":false,"creators":["Presley, Noah"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Molecular and Cellular Biology","school":null,"contributors":[],"advisors":["Dawson, John"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:48Z","subjects":["in vitro motility","actin","myosin","sarcomere","cardiology","cardiomyopathies","high-throughput"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29358","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29358","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F29358","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29358","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dawson, John"]},{"key":"dc:creator","label":"Author","values":["Presley, Noah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-10-29T16:01:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-10-29T16:01:35Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Molecular and Cellular Biology"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Molecular and Cellular Biology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["in vitro motility","actin","myosin","sarcomere","cardiology","cardiomyopathies","high-throughput"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29358"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cardiomyopathies present significant therapeutic challenges due to their genetic heterogeneity and lack of targeted treatments. The actomyosin in vitro motility (IVM) assay is a gold-standard method for studying sarcomere protein interactions; however, its traditional flow-cell format limits throughput. This research aims to adapt the IVM assay into a high-throughput format for drug screening and mechanistic analysis. A custom 96-well plate compatible with nitrocellulose-coated coverslips was developed and paired with automated imaging on a Nikon Eclipse Ti2-e. An optimized analysis pipeline using TrackMate software enabled automated filament tracking, with maximum velocity output closely matching manual tracking metrics. Validation demonstrated no significant difference in Vmax between coverslip and well-plate assays. This high-throughput IVM platform improves assay scalability and reproducibility, providing a valuable tool for screening cardiomyopathy therapies and characterizing actomyosin dynamics under diverse conditions."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Heart and Stroke Foundation of Canada"]},{"key":"dc:title","label":"Title","values":["Optimizing in Vitro Motility Assays for High-Throughput Analysis of Actin-Myosin Dynamics and Drug Screening"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dawson, John"],"dc:creator":["Presley, Noah"],"dc:date.accessioned":["2025-10-29T16:01:35Z"],"dc:date.available":["2025-10-29T16:01:35Z"],"dc:date.copyright":["2025-10"],"dc:description.abstract":["Cardiomyopathies present significant therapeutic challenges due to their genetic heterogeneity and lack of targeted treatments. The actomyosin in vitro motility (IVM) assay is a gold-standard method for studying sarcomere protein interactions; however, its traditional flow-cell format limits throughput. This research aims to adapt the IVM assay into a high-throughput format for drug screening and mechanistic analysis. A custom 96-well plate compatible with nitrocellulose-coated coverslips was developed and paired with automated imaging on a Nikon Eclipse Ti2-e. An optimized analysis pipeline using TrackMate software enabled automated filament tracking, with maximum velocity output closely matching manual tracking metrics. Validation demonstrated no significant difference in Vmax between coverslip and well-plate assays. This high-throughput IVM platform improves assay scalability and reproducibility, providing a valuable tool for screening cardiomyopathy therapies and characterizing actomyosin dynamics under diverse conditions."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Heart and Stroke Foundation of Canada"],"dc:identifier.uri":["https://hdl.handle.net/10214/29358"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["in vitro motility","actin","myosin","sarcomere","cardiology","cardiomyopathies","high-throughput"],"dc:title":["Optimizing in Vitro Motility Assays for High-Throughput Analysis of Actin-Myosin Dynamics and Drug Screening"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Molecular and Cellular Biology"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Molecular and Cellular Biology"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:48Z"}