{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29391"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29391","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Sex Differences in the Influence of Spinal Accelerometer Orientation on Transmissibility During Seated Whole-Body Vibration","abstract":"Accelerometers are used to quantify the human body’s response to seated whole-body vibration through transmissibility, where injury risk and exposure limits are defined in the ISO 2631-1 basicentric coordinate system (BCS). However, the accelerometers’ internal coordinate system becomes misaligned with the BCS when attached to the body, impacting the ability to measure transmissibility accurately. A VICON motion capture system was used to quantify tri-axial accelerometer orientation, correct accelerometer measurements to the BCS, and determine the effect of accelerometer orientation on transmissibility measured at spinal locations. 78% of participants’ accelerometers exceeded the maximum acceptable deviation (15 degrees) from the BCS recommended by ISO 2631-1. This resulted in underestimation of transmissibility in the fore-aft axis and overestimation in the vertical axis. Significant sex differences in accelerometer orientation were also identified at the sacrum and thoracic spine. This research demonstrates the necessity of correcting accelerometer orientation to accurately assess health risks for both sexes.","abstract_html":"Accelerometers are used to quantify the human body’s response to seated whole-body vibration through transmissibility, where injury risk and exposure limits are defined in the ISO 2631-1 basicentric coordinate system (BCS). However, the accelerometers’ internal coordinate system becomes misaligned with the BCS when attached to the body, impacting the ability to measure transmissibility accurately. A VICON motion capture system was used to quantify tri-axial accelerometer orientation, correct accelerometer measurements to the BCS, and determine the effect of accelerometer orientation on transmissibility measured at spinal locations. 78% of participants’ accelerometers exceeded the maximum acceptable deviation (15 degrees) from the BCS recommended by ISO 2631-1. This resulted in underestimation of transmissibility in the fore-aft axis and overestimation in the vertical axis. Significant sex differences in accelerometer orientation were also identified at the sacrum and thoracic spine. This research demonstrates the necessity of correcting accelerometer orientation to accurately assess health risks for both sexes.","abstract_has_math":false,"creators":["Cazzola, Eliza"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Oliver, Michele"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:25:17Z","subjects":["whole-body vibration","transmissibility","optical motion capture","sex differences","basicentric coordinate system"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29391","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29391","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F29391","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29391","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oliver, Michele"]},{"key":"dc:creator","label":"Author","values":["Cazzola, Eliza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-12-17T17:02:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-17T17:02:29Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-12"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["whole-body vibration","transmissibility","optical motion capture","sex differences","basicentric coordinate system"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29391"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Accelerometers are used to quantify the human body’s response to seated whole-body vibration through transmissibility, where injury risk and exposure limits are defined in the ISO 2631-1 basicentric coordinate system (BCS). However, the accelerometers’ internal coordinate system becomes misaligned with the BCS when attached to the body, impacting the ability to measure transmissibility accurately. A VICON motion capture system was used to quantify tri-axial accelerometer orientation, correct accelerometer measurements to the BCS, and determine the effect of accelerometer orientation on transmissibility measured at spinal locations. 78% of participants’ accelerometers exceeded the maximum acceptable deviation (15 degrees) from the BCS recommended by ISO 2631-1. This resulted in underestimation of transmissibility in the fore-aft axis and overestimation in the vertical axis. Significant sex differences in accelerometer orientation were also identified at the sacrum and thoracic spine. This research demonstrates the necessity of correcting accelerometer orientation to accurately assess health risks for both sexes."]},{"key":"dc:title","label":"Title","values":["Sex Differences in the Influence of Spinal Accelerometer Orientation on Transmissibility During Seated Whole-Body Vibration"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oliver, Michele"],"dc:creator":["Cazzola, Eliza"],"dc:date.accessioned":["2025-12-17T17:02:29Z"],"dc:date.available":["2025-12-17T17:02:29Z"],"dc:date.copyright":["2025-12"],"dc:description.abstract":["Accelerometers are used to quantify the human body’s response to seated whole-body vibration through transmissibility, where injury risk and exposure limits are defined in the ISO 2631-1 basicentric coordinate system (BCS). However, the accelerometers’ internal coordinate system becomes misaligned with the BCS when attached to the body, impacting the ability to measure transmissibility accurately. A VICON motion capture system was used to quantify tri-axial accelerometer orientation, correct accelerometer measurements to the BCS, and determine the effect of accelerometer orientation on transmissibility measured at spinal locations. 78% of participants’ accelerometers exceeded the maximum acceptable deviation (15 degrees) from the BCS recommended by ISO 2631-1. This resulted in underestimation of transmissibility in the fore-aft axis and overestimation in the vertical axis. Significant sex differences in accelerometer orientation were also identified at the sacrum and thoracic spine. This research demonstrates the necessity of correcting accelerometer orientation to accurately assess health risks for both sexes."],"dc:identifier.uri":["https://hdl.handle.net/10214/29391"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["whole-body vibration","transmissibility","optical motion capture","sex differences","basicentric coordinate system"],"dc:title":["Sex Differences in the Influence of Spinal Accelerometer Orientation on Transmissibility During Seated Whole-Body Vibration"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:17Z"}