{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29435"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29435","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Expanding the theory and applications of carbon dioxide and other modifier gases in differential mobility spectrometry","abstract":"This thesis explores the mechanisms and applications of CO2 and other gases or solvents for modifying the nitrogen carrier gas in differential mobility spectrometry (DMS), a technique which separates ions moving in the carrier gas through an oscillating electric field before mass spectrometry (MS) detection. Investigations include what makes CO2 a “soft” gas, and by extension, how any other gas mixture will affect this “softness”. These insights are then extended to a variety of challenging analyses. For experimental work, ions were produced with electrospray ionization (ESI) before DMS separation, and their final identification with MS. Custom modifications were made to the DMS carrier gas system to enable the use of many gas mixtures. These analyses were supplemented with quantum chemical calculations using density functional theory (DFT). This work shows evidence that a range of fragile ions are commonly protected by CO2 through efficient energy transfer during collisions, contradicting a hypothesis that ion-CO2 clusters provide the protective mechanism. More generally, it is shown that the comparative “softness” of a gas mixture can be predicted by its viscosity. These insights are then applied to show evidence that chemical analyte multimer ions are produced during the ESI process, rather than via condensation during the free jet expansion process as ions enter the MS vacuum. Control of gas conditions also factors into investigations of how to enhance the isolation of unstable prototropic isomers (protomers), showing elimination of water from the analysis is a key concern. Novel gas mixtures are considered, using an N2 carrier gas with a solvent vapour as well as some gas modifier (like CO2), to enhance resolution for challenging samples, while linking this behaviour to existing theory. This work also describes the first evidence that Ne can be a particularly useful modifier gas for DMS separations. Together, this thesis gives new insights into how the gas composition in DMS-MS can improve its performance for the separation of fragile and/or difficult to resolve ions by allowing more informed design and control of experimental conditions to enable effective analysis of challenging analytes.","abstract_html":"This thesis explores the mechanisms and applications of CO2 and other gases or solvents for modifying the nitrogen carrier gas in differential mobility spectrometry (DMS), a technique which separates ions moving in the carrier gas through an oscillating electric field before mass spectrometry (MS) detection. Investigations include what makes CO2 a “soft” gas, and by extension, how any other gas mixture will affect this “softness”. These insights are then extended to a variety of challenging analyses. For experimental work, ions were produced with electrospray ionization (ESI) before DMS separation, and their final identification with MS. Custom modifications were made to the DMS carrier gas system to enable the use of many gas mixtures. These analyses were supplemented with quantum chemical calculations using density functional theory (DFT). This work shows evidence that a range of fragile ions are commonly protected by CO2 through efficient energy transfer during collisions, contradicting a hypothesis that ion-CO2 clusters provide the protective mechanism. More generally, it is shown that the comparative “softness” of a gas mixture can be predicted by its viscosity. These insights are then applied to show evidence that chemical analyte multimer ions are produced during the ESI process, rather than via condensation during the free jet expansion process as ions enter the MS vacuum. Control of gas conditions also factors into investigations of how to enhance the isolation of unstable prototropic isomers (protomers), showing elimination of water from the analysis is a key concern. Novel gas mixtures are considered, using an N2 carrier gas with a solvent vapour as well as some gas modifier (like CO2), to enhance resolution for challenging samples, while linking this behaviour to existing theory. This work also describes the first evidence that Ne can be a particularly useful modifier gas for DMS separations. Together, this thesis gives new insights into how the gas composition in DMS-MS can improve its performance for the separation of fragile and/or difficult to resolve ions by allowing more informed design and control of experimental conditions to enable effective analysis of challenging analytes.","abstract_has_math":false,"creators":["Finlay, Andrew"],"institution":"University of Guelph","degree_name":"Doctor of Philosophy","degree_level":null,"degree_discipline":null,"degree_department":"Department of Chemistry","school":null,"contributors":[],"advisors":["Gabryelski, Wojciech"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:21:17Z","subjects":["differential mobility spectrometry","ion fragmentation","collisional cooling","ion clustering","electrospray ionization"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Finlay, A. L.; Gabryelski, W.; Hopkins, W. S. The Protective Effects of CO2 on Fragile Ions in Differential Mobility Spectrometry. J Am Soc Mass Spectrom 2025. https://doi.org/10.1021/jasms.5c00098."],"render_values":[{"text":"Finlay, A. L.; Gabryelski, W.; Hopkins, W. S. The Protective Effects of CO2 on Fragile Ions in Differential Mobility Spectrometry. J Am Soc Mass Spectrom 2025. https://doi.org/10.1021/jasms.5c00098.","href":"https://doi.org/10.1021/jasms.5c00098.","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29435","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29435","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29435","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gabryelski, Wojciech"]},{"key":"dc:creator","label":"Author","values":["Finlay, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-06T17:41:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-06T17:41:13Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2026-01"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Chemistry"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["differential mobility spectrometry","ion fragmentation","collisional cooling","ion clustering","electrospray ionization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Finlay, A. L.; Gabryelski, W.; Hopkins, W. S. The Protective Effects of CO2 on Fragile Ions in Differential Mobility Spectrometry. J Am Soc Mass Spectrom 2025. https://doi.org/10.1021/jasms.5c00098."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29435"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis explores the mechanisms and applications of CO2 and other gases or solvents for modifying the nitrogen carrier gas in differential mobility spectrometry (DMS), a technique which separates ions moving in the carrier gas through an oscillating electric field before mass spectrometry (MS) detection. Investigations include what makes CO2 a “soft” gas, and by extension, how any other gas mixture will affect this “softness”. These insights are then extended to a variety of challenging analyses. For experimental work, ions were produced with electrospray ionization (ESI) before DMS separation, and their final identification with MS. Custom modifications were made to the DMS carrier gas system to enable the use of many gas mixtures. These analyses were supplemented with quantum chemical calculations using density functional theory (DFT). This work shows evidence that a range of fragile ions are commonly protected by CO2 through efficient energy transfer during collisions, contradicting a hypothesis that ion-CO2 clusters provide the protective mechanism. More generally, it is shown that the comparative “softness” of a gas mixture can be predicted by its viscosity. These insights are then applied to show evidence that chemical analyte multimer ions are produced during the ESI process, rather than via condensation during the free jet expansion process as ions enter the MS vacuum. Control of gas conditions also factors into investigations of how to enhance the isolation of unstable prototropic isomers (protomers), showing elimination of water from the analysis is a key concern. Novel gas mixtures are considered, using an N2 carrier gas with a solvent vapour as well as some gas modifier (like CO2), to enhance resolution for challenging samples, while linking this behaviour to existing theory. This work also describes the first evidence that Ne can be a particularly useful modifier gas for DMS separations. Together, this thesis gives new insights into how the gas composition in DMS-MS can improve its performance for the separation of fragile and/or difficult to resolve ions by allowing more informed design and control of experimental conditions to enable effective analysis of challenging analytes."]},{"key":"dc:title","label":"Title","values":["Expanding the theory and applications of carbon dioxide and other modifier gases in differential mobility spectrometry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gabryelski, Wojciech"],"dc:creator":["Finlay, Andrew"],"dc:date.accessioned":["2026-01-06T17:41:13Z"],"dc:date.available":["2026-01-06T17:41:13Z"],"dc:date.copyright":["2026-01"],"dc:description.abstract":["This thesis explores the mechanisms and applications of CO2 and other gases or solvents for modifying the nitrogen carrier gas in differential mobility spectrometry (DMS), a technique which separates ions moving in the carrier gas through an oscillating electric field before mass spectrometry (MS) detection. Investigations include what makes CO2 a “soft” gas, and by extension, how any other gas mixture will affect this “softness”. These insights are then extended to a variety of challenging analyses. For experimental work, ions were produced with electrospray ionization (ESI) before DMS separation, and their final identification with MS. Custom modifications were made to the DMS carrier gas system to enable the use of many gas mixtures. These analyses were supplemented with quantum chemical calculations using density functional theory (DFT). This work shows evidence that a range of fragile ions are commonly protected by CO2 through efficient energy transfer during collisions, contradicting a hypothesis that ion-CO2 clusters provide the protective mechanism. More generally, it is shown that the comparative “softness” of a gas mixture can be predicted by its viscosity. These insights are then applied to show evidence that chemical analyte multimer ions are produced during the ESI process, rather than via condensation during the free jet expansion process as ions enter the MS vacuum. Control of gas conditions also factors into investigations of how to enhance the isolation of unstable prototropic isomers (protomers), showing elimination of water from the analysis is a key concern. Novel gas mixtures are considered, using an N2 carrier gas with a solvent vapour as well as some gas modifier (like CO2), to enhance resolution for challenging samples, while linking this behaviour to existing theory. This work also describes the first evidence that Ne can be a particularly useful modifier gas for DMS separations. Together, this thesis gives new insights into how the gas composition in DMS-MS can improve its performance for the separation of fragile and/or difficult to resolve ions by allowing more informed design and control of experimental conditions to enable effective analysis of challenging analytes."],"dc:identifier.citation":["Finlay, A. L.; Gabryelski, W.; Hopkins, W. S. The Protective Effects of CO2 on Fragile Ions in Differential Mobility Spectrometry. J Am Soc Mass Spectrom 2025. https://doi.org/10.1021/jasms.5c00098."],"dc:identifier.uri":["https://hdl.handle.net/10214/29435"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["differential mobility spectrometry","ion fragmentation","collisional cooling","ion clustering","electrospray ionization"],"dc:title":["Expanding the theory and applications of carbon dioxide and other modifier gases in differential mobility spectrometry"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Chemistry"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:degree_program":["Chemistry"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:21:17Z"}