{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/29460"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/29460","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"A Physics Based Digital Twin Framework for Motor Operated Valves","abstract":"Motor Operated valves (MOVs) are essential safety components that perform an on-off isolation and injection function under operational accidents in hydraulic power systems. The difficulty of obtaining run-to-failure data and the incapacity of basic estimation models to represent complex, concurrent, and non-linear faults limit degradation analysis for these components. Additionally, pure machine learning techniques require expert interpretation to understand fault characteristics, incurring additional costs. The model presented is built with the fidelity required to allow estimates on the MOV's availability using residual-based techniques and dynamically depict its state. To more accurately determine the current operating state, simulation strokes produced by this numerical solver are utilized for parameter estimation. The presented model serves as a precursor for future experimental validation and verification. While the simulated results from the model show agreement with literature “generalized” MOV stroke signatures, these parameters approximated.","abstract_html":"Motor Operated valves (MOVs) are essential safety components that perform an on-off isolation and injection function under operational accidents in hydraulic power systems. The difficulty of obtaining run-to-failure data and the incapacity of basic estimation models to represent complex, concurrent, and non-linear faults limit degradation analysis for these components. Additionally, pure machine learning techniques require expert interpretation to understand fault characteristics, incurring additional costs. The model presented is built with the fidelity required to allow estimates on the MOV&#x27;s availability using residual-based techniques and dynamically depict its state. To more accurately determine the current operating state, simulation strokes produced by this numerical solver are utilized for parameter estimation. The presented model serves as a precursor for future experimental validation and verification. While the simulated results from the model show agreement with literature “generalized” MOV stroke signatures, these parameters approximated.","abstract_has_math":false,"creators":["Nunziata, Nickolas"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Hassan, Marwan"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:26:28Z","subjects":["digital twin","motor operated valve","MOV","physics based modelling","condition based monitoring"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/29460","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/29460","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F29460","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F29460","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hassan, Marwan"]},{"key":"dc:creator","label":"Author","values":["Nunziata, Nickolas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-08T18:37:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-08T18:37:14Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2026-01"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["digital twin","motor operated valve","MOV","physics based modelling","condition based monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/29460"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Motor Operated valves (MOVs) are essential safety components that perform an on-off isolation and injection function under operational accidents in hydraulic power systems. The difficulty of obtaining run-to-failure data and the incapacity of basic estimation models to represent complex, concurrent, and non-linear faults limit degradation analysis for these components. Additionally, pure machine learning techniques require expert interpretation to understand fault characteristics, incurring additional costs. The model presented is built with the fidelity required to allow estimates on the MOV's availability using residual-based techniques and dynamically depict its state. To more accurately determine the current operating state, simulation strokes produced by this numerical solver are utilized for parameter estimation. The presented model serves as a precursor for future experimental validation and verification. While the simulated results from the model show agreement with literature “generalized” MOV stroke signatures, these parameters approximated."]},{"key":"dc:title","label":"Title","values":["A Physics Based Digital Twin Framework for Motor Operated Valves"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hassan, Marwan"],"dc:creator":["Nunziata, Nickolas"],"dc:date.accessioned":["2026-01-08T18:37:14Z"],"dc:date.available":["2026-01-08T18:37:14Z"],"dc:date.copyright":["2026-01"],"dc:description.abstract":["Motor Operated valves (MOVs) are essential safety components that perform an on-off isolation and injection function under operational accidents in hydraulic power systems. The difficulty of obtaining run-to-failure data and the incapacity of basic estimation models to represent complex, concurrent, and non-linear faults limit degradation analysis for these components. Additionally, pure machine learning techniques require expert interpretation to understand fault characteristics, incurring additional costs. The model presented is built with the fidelity required to allow estimates on the MOV's availability using residual-based techniques and dynamically depict its state. To more accurately determine the current operating state, simulation strokes produced by this numerical solver are utilized for parameter estimation. The presented model serves as a precursor for future experimental validation and verification. While the simulated results from the model show agreement with literature “generalized” MOV stroke signatures, these parameters approximated."],"dc:identifier.uri":["https://hdl.handle.net/10214/29460"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["digital twin","motor operated valve","MOV","physics based modelling","condition based monitoring"],"dc:title":["A Physics Based Digital Twin Framework for Motor Operated Valves"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:28Z"}