{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/30123"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/30123","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Adhesive-Augmented Sternal Fixation: Early Biomechanics, Coverage-Dependent Stability, and Multimodal Assessment of Sternal Healing in an Ovine Model","abstract":"Median sternotomy is the most common surgical approach for cardiac and thoracic procedures; however, standard stainless-steel wire cerclage provides limited resistance to micromotion and is associated with sternal dehiscence, infection, and delayed healing. Adhesive-augmented sternal fixation (AASF), which combines bone adhesive with wire cerclage, may improve load distribution and fixation stability. However, key knowledge gaps remain regarding the early mechanical behaviour of AASF before adhesive strength maturation, whether reduced adhesive coverage can maintain stability while preserving the transection line, and how structural, mechanical, and functional outcomes can be integrated in preclinical evaluation. This thesis investigated AASF using glass polyalkenoate cement (GPC), focusing on early biomechanical performance, adhesive coverage, and the integration of functional and structural outcomes in an ovine model. First, an ex vivo ovine biomechanical study evaluated fixation stability 2 hours after GPC application. Under cyclic lateral distraction loading up to 500 N, both wire-only and AASF constructs exhibited instability, with approximately 80% of specimens exceeding the 2 mm pathological displacement threshold. However, AASF appeared to reduce displacement variability, suggesting potential early load-sharing effects during adhesive maturation. Second, an ex vivo human cadaveric biomechanical study evaluated whether reduced GPC coverage could maintain fixation stability. Sternotomies repaired with 50%, 62.5%, or 75% adhesive coverage exhibited mean maximum displacements of 1.49 mm, 0.97 mm, and 0.67 mm, respectively, all below the pathological threshold. These findings demonstrate that partial adhesive coverage can maintain mechanical stability under controlled cyclic loading. Third, a 12-week in vivo ovine study evaluated inflammation-associated impairment, terminal mechanical stability, and postoperative recovery. This study integrated clinical CT imaging, macroscopic assessment, post-mortem mechanical testing, accelerometry-based activity monitoring, and pain scoring. Structural and mechanical outcomes distinguished uncomplicated healing from inflammation-associated impairment, supporting the interpretation that adverse biological healing conditions were associated with reduced mechanical competence. Functional outcomes differentiated recovery between groups overall but were not sufficiently sensitive at the current sample size to localize pathology week by week. Overall, this work provides early biomechanical characterization of GPC-based AASF, demonstrates the mechanical feasibility of partial adhesive coverage, and establishes a multimodal ovine framework for evaluating sternotomy healing, inflammation-associated impairment, and fixation stability.","abstract_html":"Median sternotomy is the most common surgical approach for cardiac and thoracic procedures; however, standard stainless-steel wire cerclage provides limited resistance to micromotion and is associated with sternal dehiscence, infection, and delayed healing. Adhesive-augmented sternal fixation (AASF), which combines bone adhesive with wire cerclage, may improve load distribution and fixation stability. However, key knowledge gaps remain regarding the early mechanical behaviour of AASF before adhesive strength maturation, whether reduced adhesive coverage can maintain stability while preserving the transection line, and how structural, mechanical, and functional outcomes can be integrated in preclinical evaluation. This thesis investigated AASF using glass polyalkenoate cement (GPC), focusing on early biomechanical performance, adhesive coverage, and the integration of functional and structural outcomes in an ovine model. First, an ex vivo ovine biomechanical study evaluated fixation stability 2 hours after GPC application. Under cyclic lateral distraction loading up to 500 N, both wire-only and AASF constructs exhibited instability, with approximately 80% of specimens exceeding the 2 mm pathological displacement threshold. However, AASF appeared to reduce displacement variability, suggesting potential early load-sharing effects during adhesive maturation. Second, an ex vivo human cadaveric biomechanical study evaluated whether reduced GPC coverage could maintain fixation stability. Sternotomies repaired with 50%, 62.5%, or 75% adhesive coverage exhibited mean maximum displacements of 1.49 mm, 0.97 mm, and 0.67 mm, respectively, all below the pathological threshold. These findings demonstrate that partial adhesive coverage can maintain mechanical stability under controlled cyclic loading. Third, a 12-week in vivo ovine study evaluated inflammation-associated impairment, terminal mechanical stability, and postoperative recovery. This study integrated clinical CT imaging, macroscopic assessment, post-mortem mechanical testing, accelerometry-based activity monitoring, and pain scoring. Structural and mechanical outcomes distinguished uncomplicated healing from inflammation-associated impairment, supporting the interpretation that adverse biological healing conditions were associated with reduced mechanical competence. Functional outcomes differentiated recovery between groups overall but were not sufficiently sensitive at the current sample size to localize pathology week by week. Overall, this work provides early biomechanical characterization of GPC-based AASF, demonstrates the mechanical feasibility of partial adhesive coverage, and establishes a multimodal ovine framework for evaluating sternotomy healing, inflammation-associated impairment, and fixation stability.","abstract_has_math":false,"creators":["Deignan, Emily"],"institution":"University of Guelph","degree_name":"Doctor of Philosophy","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Brandon, Scott"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:48Z","subjects":["median sternotomy","biomechanics","ovine model","glass polyalkenoate cement","bone adhesives"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Deignan, E., Alabassi, A., Brandon, S., Papini, M., Hurtig, M., & Towler, M. (2024). Partial coverage adhesive augmented sternal fixation and stabilization: A biomechanical analysis. Journal of Biomechanics, 177. https://doi.org/10.1016/j.jbiomech.2024.112374"],"render_values":[{"text":"Deignan, E., Alabassi, A., Brandon, S., Papini, M., Hurtig, M., & Towler, M. (2024). Partial coverage adhesive augmented sternal fixation and stabilization: A biomechanical analysis. Journal of Biomechanics, 177. https://doi.org/10.1016/j.jbiomech.2024.112374","href":"https://doi.org/10.1016/j.jbiomech.2024.112374","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/30123","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/30123","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F30123","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F30123","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brandon, Scott"]},{"key":"dc:creator","label":"Author","values":["Deignan, Emily"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-16T14:05:28Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2026-09"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["median sternotomy","biomechanics","ovine model","glass polyalkenoate cement","bone adhesives"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Deignan, E., Alabassi, A., Brandon, S., Papini, M., Hurtig, M., & Towler, M. (2024). Partial coverage adhesive augmented sternal fixation and stabilization: A biomechanical analysis. Journal of Biomechanics, 177. https://doi.org/10.1016/j.jbiomech.2024.112374"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/30123"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Median sternotomy is the most common surgical approach for cardiac and thoracic procedures; however, standard stainless-steel wire cerclage provides limited resistance to micromotion and is associated with sternal dehiscence, infection, and delayed healing. Adhesive-augmented sternal fixation (AASF), which combines bone adhesive with wire cerclage, may improve load distribution and fixation stability. However, key knowledge gaps remain regarding the early mechanical behaviour of AASF before adhesive strength maturation, whether reduced adhesive coverage can maintain stability while preserving the transection line, and how structural, mechanical, and functional outcomes can be integrated in preclinical evaluation. This thesis investigated AASF using glass polyalkenoate cement (GPC), focusing on early biomechanical performance, adhesive coverage, and the integration of functional and structural outcomes in an ovine model. First, an ex vivo ovine biomechanical study evaluated fixation stability 2 hours after GPC application. Under cyclic lateral distraction loading up to 500 N, both wire-only and AASF constructs exhibited instability, with approximately 80% of specimens exceeding the 2 mm pathological displacement threshold. However, AASF appeared to reduce displacement variability, suggesting potential early load-sharing effects during adhesive maturation. Second, an ex vivo human cadaveric biomechanical study evaluated whether reduced GPC coverage could maintain fixation stability. Sternotomies repaired with 50%, 62.5%, or 75% adhesive coverage exhibited mean maximum displacements of 1.49 mm, 0.97 mm, and 0.67 mm, respectively, all below the pathological threshold. These findings demonstrate that partial adhesive coverage can maintain mechanical stability under controlled cyclic loading. Third, a 12-week in vivo ovine study evaluated inflammation-associated impairment, terminal mechanical stability, and postoperative recovery. This study integrated clinical CT imaging, macroscopic assessment, post-mortem mechanical testing, accelerometry-based activity monitoring, and pain scoring. Structural and mechanical outcomes distinguished uncomplicated healing from inflammation-associated impairment, supporting the interpretation that adverse biological healing conditions were associated with reduced mechanical competence. Functional outcomes differentiated recovery between groups overall but were not sufficiently sensitive at the current sample size to localize pathology week by week. Overall, this work provides early biomechanical characterization of GPC-based AASF, demonstrates the mechanical feasibility of partial adhesive coverage, and establishes a multimodal ovine framework for evaluating sternotomy healing, inflammation-associated impairment, and fixation stability."]},{"key":"dc:title","label":"Title","values":["Adhesive-Augmented Sternal Fixation: Early Biomechanics, Coverage-Dependent Stability, and Multimodal Assessment of Sternal Healing in an Ovine Model"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brandon, Scott"],"dc:creator":["Deignan, Emily"],"dc:date.accessioned":["2026-09-16T14:05:28Z"],"dc:date.copyright":["2026-09"],"dc:description.abstract":["Median sternotomy is the most common surgical approach for cardiac and thoracic procedures; however, standard stainless-steel wire cerclage provides limited resistance to micromotion and is associated with sternal dehiscence, infection, and delayed healing. Adhesive-augmented sternal fixation (AASF), which combines bone adhesive with wire cerclage, may improve load distribution and fixation stability. However, key knowledge gaps remain regarding the early mechanical behaviour of AASF before adhesive strength maturation, whether reduced adhesive coverage can maintain stability while preserving the transection line, and how structural, mechanical, and functional outcomes can be integrated in preclinical evaluation. This thesis investigated AASF using glass polyalkenoate cement (GPC), focusing on early biomechanical performance, adhesive coverage, and the integration of functional and structural outcomes in an ovine model. First, an ex vivo ovine biomechanical study evaluated fixation stability 2 hours after GPC application. Under cyclic lateral distraction loading up to 500 N, both wire-only and AASF constructs exhibited instability, with approximately 80% of specimens exceeding the 2 mm pathological displacement threshold. However, AASF appeared to reduce displacement variability, suggesting potential early load-sharing effects during adhesive maturation. Second, an ex vivo human cadaveric biomechanical study evaluated whether reduced GPC coverage could maintain fixation stability. Sternotomies repaired with 50%, 62.5%, or 75% adhesive coverage exhibited mean maximum displacements of 1.49 mm, 0.97 mm, and 0.67 mm, respectively, all below the pathological threshold. These findings demonstrate that partial adhesive coverage can maintain mechanical stability under controlled cyclic loading. Third, a 12-week in vivo ovine study evaluated inflammation-associated impairment, terminal mechanical stability, and postoperative recovery. This study integrated clinical CT imaging, macroscopic assessment, post-mortem mechanical testing, accelerometry-based activity monitoring, and pain scoring. Structural and mechanical outcomes distinguished uncomplicated healing from inflammation-associated impairment, supporting the interpretation that adverse biological healing conditions were associated with reduced mechanical competence. Functional outcomes differentiated recovery between groups overall but were not sufficiently sensitive at the current sample size to localize pathology week by week. Overall, this work provides early biomechanical characterization of GPC-based AASF, demonstrates the mechanical feasibility of partial adhesive coverage, and establishes a multimodal ovine framework for evaluating sternotomy healing, inflammation-associated impairment, and fixation stability."],"dc:identifier.citation":["Deignan, E., Alabassi, A., Brandon, S., Papini, M., Hurtig, M., & Towler, M. (2024). Partial coverage adhesive augmented sternal fixation and stabilization: A biomechanical analysis. Journal of Biomechanics, 177. https://doi.org/10.1016/j.jbiomech.2024.112374"],"dc:identifier.uri":["https://hdl.handle.net/10214/30123"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["median sternotomy","biomechanics","ovine model","glass polyalkenoate cement","bone adhesives"],"dc:title":["Adhesive-Augmented Sternal Fixation: Early Biomechanics, Coverage-Dependent Stability, and Multimodal Assessment of Sternal Healing in an Ovine Model"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:48Z"}