{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/3170"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/3170","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Comparison between Hybrid Moving Bed Membrane Bioreactor and Conventional Membrane Bioreactor Processes in Municipal Wastewater Treatment","abstract":"A conventional membrane bioreactor (MBR) and two moving bed bioreactors coupled with ultrafiltration membrane filtration were operated for close to six months to investigate biological nutrient removal and potential fouling inducing parameter mitigation. Unique to one of the moving bed membrane bioreactors (MBMBR) was a newly designed media that incorporated a hydrodynamic exterior carrier with a highly porous interior packing. Preliminary investigation indicates that nitrogen compounds were superiorly removed in the two MBMBRs when compared with the MBR. This is a result of denitrification processes occurring in anoxic micro-zones found within the depths of the biofilm affixed to media. Fouling propensity was found to be increased by over four times in the MBMBR systems as compared to the MBR. Mixed liquor, permeate and filtrate analysis, membrane fibre examination and permeability tests indicated that colloidal organic carbon, as well as soluble microbial products were the dominant fouling inducing compounds.","abstract_html":"A conventional membrane bioreactor (MBR) and two moving bed bioreactors coupled with ultrafiltration membrane filtration were operated for close to six months to investigate biological nutrient removal and potential fouling inducing parameter mitigation. Unique to one of the moving bed membrane bioreactors (MBMBR) was a newly designed media that incorporated a hydrodynamic exterior carrier with a highly porous interior packing. Preliminary investigation indicates that nitrogen compounds were superiorly removed in the two MBMBRs when compared with the MBR. This is a result of denitrification processes occurring in anoxic micro-zones found within the depths of the biofilm affixed to media. Fouling propensity was found to be increased by over four times in the MBMBR systems as compared to the MBR. Mixed liquor, permeate and filtrate analysis, membrane fibre examination and permeability tests indicated that colloidal organic carbon, as well as soluble microbial products were the dominant fouling inducing compounds.","abstract_has_math":false,"creators":["Rollings-Scattergood, Sasha Michael"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Zhou, Hongde"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-12-08","date_published":"2011-12-08","updated_at":"2026-11-19T08:25:20Z","subjects":["moving bed bioreactor","MBBR","moving bed membrane bioreactor","MBMBR","biofilm membrane bioreactor","BF-MBR","membrane bioreactor","MBR","nutrient removal","wastewater","biofilm","carrier","FT-IR","CLSM","Fourier transform infrared","confocal laser scanning microscopy","fouling"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/3170","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/3170","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F3170","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhou, Hongde"]},{"key":"dc:creator","label":"Author","values":["Rollings-Scattergood, Sasha Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-12-08T14:13:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-12-08T14:13:50Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011-11"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-11-15"]},{"key":"dc:date.issued","label":"Date","values":["2011-12-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["moving bed bioreactor","MBBR","moving bed membrane bioreactor","MBMBR","biofilm membrane bioreactor","BF-MBR","membrane bioreactor","MBR","nutrient removal","wastewater","biofilm","carrier","FT-IR","CLSM","Fourier transform infrared","confocal laser scanning microscopy","fouling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/3170"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Manuscript format"]},{"key":"dc:description.abstract","label":"Abstract","values":["A conventional membrane bioreactor (MBR) and two moving bed bioreactors coupled with ultrafiltration membrane filtration were operated for close to six months to investigate biological nutrient removal and potential fouling inducing parameter mitigation. Unique to one of the moving bed membrane bioreactors (MBMBR) was a newly designed media that incorporated a hydrodynamic exterior carrier with a highly porous interior packing. Preliminary investigation indicates that nitrogen compounds were superiorly removed in the two MBMBRs when compared with the MBR. This is a result of denitrification processes occurring in anoxic micro-zones found within the depths of the biofilm affixed to media. Fouling propensity was found to be increased by over four times in the MBMBR systems as compared to the MBR. Mixed liquor, permeate and filtrate analysis, membrane fibre examination and permeability tests indicated that colloidal organic carbon, as well as soluble microbial products were the dominant fouling inducing compounds."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada"]},{"key":"dc:title","label":"Title","values":["Comparison between Hybrid Moving Bed Membrane Bioreactor and Conventional Membrane Bioreactor Processes in Municipal Wastewater Treatment"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhou, Hongde"],"dc:creator":["Rollings-Scattergood, Sasha Michael"],"dc:date.accessioned":["2011-12-08T14:13:50Z"],"dc:date.available":["2011-12-08T14:13:50Z"],"dc:date.copyright":["2011-11"],"dc:date.created":["2011-11-15"],"dc:date.issued":["2011-12-08"],"dc:description":["Manuscript format"],"dc:description.abstract":["A conventional membrane bioreactor (MBR) and two moving bed bioreactors coupled with ultrafiltration membrane filtration were operated for close to six months to investigate biological nutrient removal and potential fouling inducing parameter mitigation. Unique to one of the moving bed membrane bioreactors (MBMBR) was a newly designed media that incorporated a hydrodynamic exterior carrier with a highly porous interior packing. Preliminary investigation indicates that nitrogen compounds were superiorly removed in the two MBMBRs when compared with the MBR. This is a result of denitrification processes occurring in anoxic micro-zones found within the depths of the biofilm affixed to media. Fouling propensity was found to be increased by over four times in the MBMBR systems as compared to the MBR. Mixed liquor, permeate and filtrate analysis, membrane fibre examination and permeability tests indicated that colloidal organic carbon, as well as soluble microbial products were the dominant fouling inducing compounds."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada"],"dc:identifier.uri":["http://hdl.handle.net/10214/3170"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["moving bed bioreactor","MBBR","moving bed membrane bioreactor","MBMBR","biofilm membrane bioreactor","BF-MBR","membrane bioreactor","MBR","nutrient removal","wastewater","biofilm","carrier","FT-IR","CLSM","Fourier transform infrared","confocal laser scanning microscopy","fouling"],"dc:title":["Comparison between Hybrid Moving Bed Membrane Bioreactor and Conventional Membrane Bioreactor Processes in Municipal Wastewater Treatment"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:20Z"}