{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/3373"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/3373","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"The Safe Design of a Continuous Supercritical Fluid Extraction System for the Treatment of Drill Cuttings","abstract":"The objective of this research was to design a pilot scale continuous supercritical fluid extraction (SFE) system for the treatment of drill cuttings.The design includes: • A Piping and instrumentation diagram (P&ID) • A control philosophy • An operation manual, and • A HAZOP analysis The pilot scale SFE system was designed using a HAZOP-inspired framework, which resulted in the inclusion of risk reducing measures. This design approach was appropriate for the design of a novel technology, as risk reduction was made the inherent priority throughout the process. No major changes were made to the design during the professionally conducted safety analysis (HAZOP), thus the design is considered to be well positioned to operate safely. Recommended, non-critical future design improvements include: • Separation of the process control from the safety control systems • Continuous reduction of “human factors”, and • Review of all changes to the design before implementation","abstract_html":"The objective of this research was to design a pilot scale continuous supercritical fluid extraction (SFE) system for the treatment of drill cuttings.The design includes: • A Piping and instrumentation diagram (P&amp;ID) • A control philosophy • An operation manual, and • A HAZOP analysis The pilot scale SFE system was designed using a HAZOP-inspired framework, which resulted in the inclusion of risk reducing measures. This design approach was appropriate for the design of a novel technology, as risk reduction was made the inherent priority throughout the process. No major changes were made to the design during the professionally conducted safety analysis (HAZOP), thus the design is considered to be well positioned to operate safely. Recommended, non-critical future design improvements include: • Separation of the process control from the safety control systems • Continuous reduction of “human factors”, and • Review of all changes to the design before implementation","abstract_has_math":false,"creators":["Rosenthal, Angelique"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Stiver, Warren"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-03-06","date_published":"2012-03-06","updated_at":"2026-11-19T08:22:27Z","subjects":["supercritical fluid","supercritical fluid extraction","drill cuttings"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10214/3373","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10214/3373","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F3373","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stiver, Warren"]},{"key":"dc:creator","label":"Author","values":["Rosenthal, Angelique"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-06T18:43:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-27T06:00:09Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2012-02"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-02-27"]},{"key":"dc:date.issued","label":"Date","values":["2012-03-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["supercritical fluid","supercritical fluid extraction","drill cuttings"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/3373"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research was to design a pilot scale continuous supercritical fluid extraction (SFE) system for the treatment of drill cuttings.The design includes: • A Piping and instrumentation diagram (P&ID) • A control philosophy • An operation manual, and • A HAZOP analysis The pilot scale SFE system was designed using a HAZOP-inspired framework, which resulted in the inclusion of risk reducing measures. This design approach was appropriate for the design of a novel technology, as risk reduction was made the inherent priority throughout the process. No major changes were made to the design during the professionally conducted safety analysis (HAZOP), thus the design is considered to be well positioned to operate safely. Recommended, non-critical future design improvements include: • Separation of the process control from the safety control systems • Continuous reduction of “human factors”, and • Review of all changes to the design before implementation"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","M-I SWACO, a Schlumberger Company"]},{"key":"dc:title","label":"Title","values":["The Safe Design of a Continuous Supercritical Fluid Extraction System for the Treatment of Drill Cuttings"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stiver, Warren"],"dc:creator":["Rosenthal, Angelique"],"dc:date.accessioned":["2012-03-06T18:43:27Z"],"dc:date.available":["2013-02-27T06:00:09Z"],"dc:date.copyright":["2012-02"],"dc:date.created":["2012-02-27"],"dc:date.issued":["2012-03-06"],"dc:description.abstract":["The objective of this research was to design a pilot scale continuous supercritical fluid extraction (SFE) system for the treatment of drill cuttings.The design includes: • A Piping and instrumentation diagram (P&ID) • A control philosophy • An operation manual, and • A HAZOP analysis The pilot scale SFE system was designed using a HAZOP-inspired framework, which resulted in the inclusion of risk reducing measures. This design approach was appropriate for the design of a novel technology, as risk reduction was made the inherent priority throughout the process. No major changes were made to the design during the professionally conducted safety analysis (HAZOP), thus the design is considered to be well positioned to operate safely. Recommended, non-critical future design improvements include: • Separation of the process control from the safety control systems • Continuous reduction of “human factors”, and • Review of all changes to the design before implementation"],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","M-I SWACO, a Schlumberger Company"],"dc:identifier.uri":["http://hdl.handle.net/10214/3373"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["supercritical fluid","supercritical fluid extraction","drill cuttings"],"dc:title":["The Safe Design of a Continuous Supercritical Fluid Extraction System for the Treatment of Drill Cuttings"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:27Z"}