{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/3637"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/3637","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"The Development of Seasonal Baseline Emission Factors for Aerial Pollutants Produced by a Commercial Layer Facility","abstract":"From a human health perspective, pollutants emitted from agricultural facilities are a growing concern. Quantification of these aerial pollutants is difficult due to variable climatic conditions, the number of animal species used in commercial operations and the wide range of management conditions used for each species. A project was initiated to quantify the emissions of ammonia and particulate matter over a period of one year from a commercial poultry layer facility in Ontario. An on-site mobile trailer was used to monitor in-house concentrations of ammonia and size fractioned particulate matter via a heated sample line. Along with a developed ventilation profile, emissions rates were produced for the facility. Average emissions of 19.53 ± 19.97, 2.57 ± 2.17, and 1.10 ± 1.52 g/day/AU for ammonia, PM10, and PM2.5, respectively, was observed from the layer facility. Emissions peaked during the winter months except for PM2.5 which had increased emissions in the summer.","abstract_html":"From a human health perspective, pollutants emitted from agricultural facilities are a growing concern. Quantification of these aerial pollutants is difficult due to variable climatic conditions, the number of animal species used in commercial operations and the wide range of management conditions used for each species. A project was initiated to quantify the emissions of ammonia and particulate matter over a period of one year from a commercial poultry layer facility in Ontario. An on-site mobile trailer was used to monitor in-house concentrations of ammonia and size fractioned particulate matter via a heated sample line. Along with a developed ventilation profile, emissions rates were produced for the facility. Average emissions of 19.53 ± 19.97, 2.57 ± 2.17, and 1.10 ± 1.52 g/day/AU for ammonia, PM10, and PM2.5, respectively, was observed from the layer facility. Emissions peaked during the winter months except for PM2.5 which had increased emissions in the summer.","abstract_has_math":false,"creators":["Morgan, Robert"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Van Heyst, Bill"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-05-14","date_published":"2012-05-14","updated_at":"2026-11-19T08:26:50Z","subjects":["emissions","ammonia","particulate matter","commercial poultry layer facility"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/3637","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/3637","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F3637","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F3637","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Van Heyst, Bill"]},{"key":"dc:creator","label":"Author","values":["Morgan, Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-05-14T20:06:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-05-14T20:06:13Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2012"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-05-08"]},{"key":"dc:date.issued","label":"Date","values":["2012-05-14"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["emissions","ammonia","particulate matter","commercial poultry layer facility"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/3637"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["From a human health perspective, pollutants emitted from agricultural facilities are a growing concern. Quantification of these aerial pollutants is difficult due to variable climatic conditions, the number of animal species used in commercial operations and the wide range of management conditions used for each species. A project was initiated to quantify the emissions of ammonia and particulate matter over a period of one year from a commercial poultry layer facility in Ontario. An on-site mobile trailer was used to monitor in-house concentrations of ammonia and size fractioned particulate matter via a heated sample line. Along with a developed ventilation profile, emissions rates were produced for the facility. Average emissions of 19.53 ± 19.97, 2.57 ± 2.17, and 1.10 ± 1.52 g/day/AU for ammonia, PM10, and PM2.5, respectively, was observed from the layer facility. Emissions peaked during the winter months except for PM2.5 which had increased emissions in the summer."]},{"key":"dc:title","label":"Title","values":["The Development of Seasonal Baseline Emission Factors for Aerial Pollutants Produced by a Commercial Layer Facility"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Van Heyst, Bill"],"dc:creator":["Morgan, Robert"],"dc:date.accessioned":["2012-05-14T20:06:13Z"],"dc:date.available":["2012-05-14T20:06:13Z"],"dc:date.copyright":["2012"],"dc:date.created":["2012-05-08"],"dc:date.issued":["2012-05-14"],"dc:description.abstract":["From a human health perspective, pollutants emitted from agricultural facilities are a growing concern. Quantification of these aerial pollutants is difficult due to variable climatic conditions, the number of animal species used in commercial operations and the wide range of management conditions used for each species. A project was initiated to quantify the emissions of ammonia and particulate matter over a period of one year from a commercial poultry layer facility in Ontario. An on-site mobile trailer was used to monitor in-house concentrations of ammonia and size fractioned particulate matter via a heated sample line. Along with a developed ventilation profile, emissions rates were produced for the facility. Average emissions of 19.53 ± 19.97, 2.57 ± 2.17, and 1.10 ± 1.52 g/day/AU for ammonia, PM10, and PM2.5, respectively, was observed from the layer facility. Emissions peaked during the winter months except for PM2.5 which had increased emissions in the summer."],"dc:identifier.uri":["http://hdl.handle.net/10214/3637"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["emissions","ammonia","particulate matter","commercial poultry layer facility"],"dc:title":["The Development of Seasonal Baseline Emission Factors for Aerial Pollutants Produced by a Commercial Layer Facility"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:50Z"}