{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/5265"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/5265","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"A Novel Technique for Depth Discrete Flow Characterization: Fibre Optic Distributed Temperature Sensing within Boreholes Sealed with Flexible Underground Liners","abstract":"In recent years, wireline temperature profiling methods have evolved to offer new insight into fractured rock hydrogeology. An important advance in temperature logging makes use of boreholes temporarily sealed with flexible impervious fabric liners so that the water column is static and effects of cross-connection are eliminated. For this project a characterization technique was developed based on combining fibre optic distributed temperatures sensing (DTS) with active heating within boreholes sealed with underground liners. DTS systems provide a temperature profiling method that offers improved temporal resolution when compared with wireline trolling based techniques. The ability to collect temperature profiles rapidly in time can improve understanding of transient processes. In this study the advantage of a sealed borehole environment for temperature investigations is demonstrated. Evidence for identifying active groundwater flow under natural gradient conditions using DTS heat pulse testing is presented through a comparison with high resolution geologic logging and hydraulic datasets.","abstract_html":"In recent years, wireline temperature profiling methods have evolved to offer new insight into fractured rock hydrogeology. An important advance in temperature logging makes use of boreholes temporarily sealed with flexible impervious fabric liners so that the water column is static and effects of cross-connection are eliminated. For this project a characterization technique was developed based on combining fibre optic distributed temperatures sensing (DTS) with active heating within boreholes sealed with underground liners. DTS systems provide a temperature profiling method that offers improved temporal resolution when compared with wireline trolling based techniques. The ability to collect temperature profiles rapidly in time can improve understanding of transient processes. In this study the advantage of a sealed borehole environment for temperature investigations is demonstrated. Evidence for identifying active groundwater flow under natural gradient conditions using DTS heat pulse testing is presented through a comparison with high resolution geologic logging and hydraulic datasets.","abstract_has_math":false,"creators":["Coleman, Thomas"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Parker, Beth"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-01-09","date_published":"2013-01-09","updated_at":"2026-11-19T08:26:37Z","subjects":["hydrogeology","groundwater","fractured rock","distributed temperature sensing","temperature tracer"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/5265","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/5265","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F5265","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parker, Beth"]},{"key":"dc:creator","label":"Author","values":["Coleman, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-09T19:39:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-09T19:39:37Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-12-21"]},{"key":"dc:date.issued","label":"Date","values":["2013-01-09"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["hydrogeology","groundwater","fractured rock","distributed temperature sensing","temperature tracer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/5265"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In recent years, wireline temperature profiling methods have evolved to offer new insight into fractured rock hydrogeology. An important advance in temperature logging makes use of boreholes temporarily sealed with flexible impervious fabric liners so that the water column is static and effects of cross-connection are eliminated. For this project a characterization technique was developed based on combining fibre optic distributed temperatures sensing (DTS) with active heating within boreholes sealed with underground liners. DTS systems provide a temperature profiling method that offers improved temporal resolution when compared with wireline trolling based techniques. The ability to collect temperature profiles rapidly in time can improve understanding of transient processes. In this study the advantage of a sealed borehole environment for temperature investigations is demonstrated. Evidence for identifying active groundwater flow under natural gradient conditions using DTS heat pulse testing is presented through a comparison with high resolution geologic logging and hydraulic datasets."]},{"key":"dc:title","label":"Title","values":["A Novel Technique for Depth Discrete Flow Characterization: Fibre Optic Distributed Temperature Sensing within Boreholes Sealed with Flexible Underground Liners"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parker, Beth"],"dc:creator":["Coleman, Thomas"],"dc:date.accessioned":["2013-01-09T19:39:37Z"],"dc:date.available":["2013-01-09T19:39:37Z"],"dc:date.copyright":["2013-01"],"dc:date.created":["2012-12-21"],"dc:date.issued":["2013-01-09"],"dc:description.abstract":["In recent years, wireline temperature profiling methods have evolved to offer new insight into fractured rock hydrogeology. An important advance in temperature logging makes use of boreholes temporarily sealed with flexible impervious fabric liners so that the water column is static and effects of cross-connection are eliminated. For this project a characterization technique was developed based on combining fibre optic distributed temperatures sensing (DTS) with active heating within boreholes sealed with underground liners. DTS systems provide a temperature profiling method that offers improved temporal resolution when compared with wireline trolling based techniques. The ability to collect temperature profiles rapidly in time can improve understanding of transient processes. In this study the advantage of a sealed borehole environment for temperature investigations is demonstrated. Evidence for identifying active groundwater flow under natural gradient conditions using DTS heat pulse testing is presented through a comparison with high resolution geologic logging and hydraulic datasets."],"dc:identifier.uri":["http://hdl.handle.net/10214/5265"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["hydrogeology","groundwater","fractured rock","distributed temperature sensing","temperature tracer"],"dc:title":["A Novel Technique for Depth Discrete Flow Characterization: Fibre Optic Distributed Temperature Sensing within Boreholes Sealed with Flexible Underground Liners"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:37Z"}