{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/5322"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/5322","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Energy Monitoring System for Security and Energy Management Applications","abstract":"This thesis presents an energy monitoring system to measure energy consumption of software applications to support security and power management for embedded devices. The proposed system is composed of an Actel Fusion device and a custom designed energy measurement circuit. The Fusion device measures the voltage and the current of the target device at a defined sampling rate. The energy measurement circuit is designed as a current integrator over fixed intervals using the switched-capacitor integrator technique to store energy information of the target device within Fusion’s sampling intervals. This circuit is designed to accommodate the low sampling rate of the Fusion device. Experimental results showed that the Fusion device allows the measurement of the energy of the target device at a minimum rate of 15 µs. The energy measurement circuit is implemented using the 65 nm CMOS technology. Simulation results showed that this circuit provides 91%~97% average energy measurement accuracy.","abstract_html":"This thesis presents an energy monitoring system to measure energy consumption of software applications to support security and power management for embedded devices. The proposed system is composed of an Actel Fusion device and a custom designed energy measurement circuit. The Fusion device measures the voltage and the current of the target device at a defined sampling rate. The energy measurement circuit is designed as a current integrator over fixed intervals using the switched-capacitor integrator technique to store energy information of the target device within Fusion’s sampling intervals. This circuit is designed to accommodate the low sampling rate of the Fusion device. Experimental results showed that the Fusion device allows the measurement of the energy of the target device at a minimum rate of 15 µs. The energy measurement circuit is implemented using the 65 nm CMOS technology. Simulation results showed that this circuit provides 91%~97% average energy measurement accuracy.","abstract_has_math":false,"creators":["Shariati, Sepideh"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Muresan, Radu","Vannelli, Anthony"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-01-16","date_published":"2013-01-16","updated_at":"2026-11-19T08:24:16Z","subjects":["energy monitoring system","energy measurement circuit","mixed-signal FPGA","switched-capacitor integrator"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/5322","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/5322","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F5322","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Muresan, Radu","Vannelli, Anthony"]},{"key":"dc:creator","label":"Author","values":["Shariati, Sepideh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-16T15:41:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-16T15:41:23Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-12-13"]},{"key":"dc:date.issued","label":"Date","values":["2013-01-16"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["energy monitoring system","energy measurement circuit","mixed-signal FPGA","switched-capacitor integrator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/5322"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents an energy monitoring system to measure energy consumption of software applications to support security and power management for embedded devices. The proposed system is composed of an Actel Fusion device and a custom designed energy measurement circuit. The Fusion device measures the voltage and the current of the target device at a defined sampling rate. The energy measurement circuit is designed as a current integrator over fixed intervals using the switched-capacitor integrator technique to store energy information of the target device within Fusion’s sampling intervals. This circuit is designed to accommodate the low sampling rate of the Fusion device. Experimental results showed that the Fusion device allows the measurement of the energy of the target device at a minimum rate of 15 µs. The energy measurement circuit is implemented using the 65 nm CMOS technology. Simulation results showed that this circuit provides 91%~97% average energy measurement accuracy."]},{"key":"dc:title","label":"Title","values":["Energy Monitoring System for Security and Energy Management Applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Muresan, Radu","Vannelli, Anthony"],"dc:creator":["Shariati, Sepideh"],"dc:date.accessioned":["2013-01-16T15:41:23Z"],"dc:date.available":["2013-01-16T15:41:23Z"],"dc:date.copyright":["2013-01"],"dc:date.created":["2012-12-13"],"dc:date.issued":["2013-01-16"],"dc:description.abstract":["This thesis presents an energy monitoring system to measure energy consumption of software applications to support security and power management for embedded devices. The proposed system is composed of an Actel Fusion device and a custom designed energy measurement circuit. The Fusion device measures the voltage and the current of the target device at a defined sampling rate. The energy measurement circuit is designed as a current integrator over fixed intervals using the switched-capacitor integrator technique to store energy information of the target device within Fusion’s sampling intervals. This circuit is designed to accommodate the low sampling rate of the Fusion device. Experimental results showed that the Fusion device allows the measurement of the energy of the target device at a minimum rate of 15 µs. The energy measurement circuit is implemented using the 65 nm CMOS technology. Simulation results showed that this circuit provides 91%~97% average energy measurement accuracy."],"dc:identifier.uri":["http://hdl.handle.net/10214/5322"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["energy monitoring system","energy measurement circuit","mixed-signal FPGA","switched-capacitor integrator"],"dc:title":["Energy Monitoring System for Security and Energy Management Applications"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:16Z"}