{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/7373"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/7373","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Development of a Pneumatic Hand Training Device for Stroke Rehabilitation","abstract":"A new hand training system has been designed and built to help clinicians administrate hand therapy to stroke patients. It uses pneumatics to actuate the fingers from the dorsal side of the hand in order to provide training for activities of daily living. Before the device is tested in a clinical trial, it’s safety, comfort and reliability needed to be established via trials on 30 healthy individuals. A comfort survey that was issued to the users indicated that they found the device comfortable regardless of age, gender, weight and hand length. The sensor data that was gathered during testing indicated that the readings were reliable and the device had minimal impact on the subjects' normal range of motion. A bio-mechanical model, validated through experimentation, was also created to estimate joint angles of the index finger during the trials to ensure that the device put the joints of the finger in bio-mechanically safe angles.","abstract_html":"A new hand training system has been designed and built to help clinicians administrate hand therapy to stroke patients. It uses pneumatics to actuate the fingers from the dorsal side of the hand in order to provide training for activities of daily living. Before the device is tested in a clinical trial, it’s safety, comfort and reliability needed to be established via trials on 30 healthy individuals. A comfort survey that was issued to the users indicated that they found the device comfortable regardless of age, gender, weight and hand length. The sensor data that was gathered during testing indicated that the readings were reliable and the device had minimal impact on the subjects&#x27; normal range of motion. A bio-mechanical model, validated through experimentation, was also created to estimate joint angles of the index finger during the trials to ensure that the device put the joints of the finger in bio-mechanically safe angles.","abstract_has_math":false,"creators":["Jackson, Gregory"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Abdullah, Hussein"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-08-16","date_published":"2013-08-16","updated_at":"2026-11-19T08:22:59Z","subjects":["Robotics","Pneumatics","Robotic Rehabilitation","Therapeutic Devices"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/7373","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/7373","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F7373","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F7373","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abdullah, Hussein"]},{"key":"dc:creator","label":"Author","values":["Jackson, Gregory"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-16T14:16:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-24T05:00:13Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013-07"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-07-24"]},{"key":"dc:date.issued","label":"Date","values":["2013-08-16"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Robotics","Pneumatics","Robotic Rehabilitation","Therapeutic Devices"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/7373"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A new hand training system has been designed and built to help clinicians administrate hand therapy to stroke patients. It uses pneumatics to actuate the fingers from the dorsal side of the hand in order to provide training for activities of daily living. Before the device is tested in a clinical trial, it’s safety, comfort and reliability needed to be established via trials on 30 healthy individuals. A comfort survey that was issued to the users indicated that they found the device comfortable regardless of age, gender, weight and hand length. The sensor data that was gathered during testing indicated that the readings were reliable and the device had minimal impact on the subjects' normal range of motion. A bio-mechanical model, validated through experimentation, was also created to estimate joint angles of the index finger during the trials to ensure that the device put the joints of the finger in bio-mechanically safe angles."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada"]},{"key":"dc:title","label":"Title","values":["Development of a Pneumatic Hand Training Device for Stroke Rehabilitation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abdullah, Hussein"],"dc:creator":["Jackson, Gregory"],"dc:date.accessioned":["2013-08-16T14:16:43Z"],"dc:date.available":["2014-07-24T05:00:13Z"],"dc:date.copyright":["2013-07"],"dc:date.created":["2013-07-24"],"dc:date.issued":["2013-08-16"],"dc:description.abstract":["A new hand training system has been designed and built to help clinicians administrate hand therapy to stroke patients. It uses pneumatics to actuate the fingers from the dorsal side of the hand in order to provide training for activities of daily living. Before the device is tested in a clinical trial, it’s safety, comfort and reliability needed to be established via trials on 30 healthy individuals. A comfort survey that was issued to the users indicated that they found the device comfortable regardless of age, gender, weight and hand length. The sensor data that was gathered during testing indicated that the readings were reliable and the device had minimal impact on the subjects' normal range of motion. A bio-mechanical model, validated through experimentation, was also created to estimate joint angles of the index finger during the trials to ensure that the device put the joints of the finger in bio-mechanically safe angles."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada"],"dc:identifier.uri":["http://hdl.handle.net/10214/7373"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["Robotics","Pneumatics","Robotic Rehabilitation","Therapeutic Devices"],"dc:title":["Development of a Pneumatic Hand Training Device for Stroke Rehabilitation"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:59Z"}