{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/7496"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/7496","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Biomechanical Properties of the Transverse Carpal Ligament","abstract":"The mechanical properties of the transverse carpal ligament (TCL) have yet to be comprehensively measured. Failure strain, failure load, ultimate strength, stiffness and elastic modulus were reported from uniaxial tensile tests. On human cadaveric TCLs, failure strain was significantly higher in female specimens compared to males. Moreover, regional strain analysis showed the lateral end of the tissue to strain significantly more than the medial. Biaxial testing at three different tissue depths was also carried out. Mechanical properties were found to vary significantly by depth with the deeper layers displaying higher mechanical properties. A significant difference with respect to loading direction was also observed with the medial/lateral direction displaying higher mechanical properties than proximal/distal. These results provide mechanical properties which can be incorporated into finite element models or constitutive models of the TCL. Furthermore, this work provides a basis for recommendations for non-invasive treatment options for carpal tunnel syndrome.","abstract_html":"The mechanical properties of the transverse carpal ligament (TCL) have yet to be comprehensively measured. Failure strain, failure load, ultimate strength, stiffness and elastic modulus were reported from uniaxial tensile tests. On human cadaveric TCLs, failure strain was significantly higher in female specimens compared to males. Moreover, regional strain analysis showed the lateral end of the tissue to strain significantly more than the medial. Biaxial testing at three different tissue depths was also carried out. Mechanical properties were found to vary significantly by depth with the deeper layers displaying higher mechanical properties. A significant difference with respect to loading direction was also observed with the medial/lateral direction displaying higher mechanical properties than proximal/distal. These results provide mechanical properties which can be incorporated into finite element models or constitutive models of the TCL. Furthermore, this work provides a basis for recommendations for non-invasive treatment options for carpal tunnel syndrome.","abstract_has_math":false,"creators":["Brett, Allan"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Gordon, Karen"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-09-10","date_published":"2013-09-10","updated_at":"2026-11-19T08:27:51Z","subjects":["transverse carpal ligament (syn: flexor retunaculum)","carpal tunnel syndrome","biomechanical properties","biaxial testing"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/7496","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/7496","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F7496","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F7496","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gordon, Karen"]},{"key":"dc:creator","label":"Author","values":["Brett, Allan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-10T16:11:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-09-10T16:11:48Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-08-16"]},{"key":"dc:date.issued","label":"Date","values":["2013-09-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["transverse carpal ligament (syn: flexor retunaculum)","carpal tunnel syndrome","biomechanical properties","biaxial testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/7496"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The mechanical properties of the transverse carpal ligament (TCL) have yet to be comprehensively measured. Failure strain, failure load, ultimate strength, stiffness and elastic modulus were reported from uniaxial tensile tests. On human cadaveric TCLs, failure strain was significantly higher in female specimens compared to males. Moreover, regional strain analysis showed the lateral end of the tissue to strain significantly more than the medial. Biaxial testing at three different tissue depths was also carried out. Mechanical properties were found to vary significantly by depth with the deeper layers displaying higher mechanical properties. A significant difference with respect to loading direction was also observed with the medial/lateral direction displaying higher mechanical properties than proximal/distal. These results provide mechanical properties which can be incorporated into finite element models or constitutive models of the TCL. Furthermore, this work provides a basis for recommendations for non-invasive treatment options for carpal tunnel syndrome."]},{"key":"dc:title","label":"Title","values":["Biomechanical Properties of the Transverse Carpal Ligament"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gordon, Karen"],"dc:creator":["Brett, Allan"],"dc:date.accessioned":["2013-09-10T16:11:48Z"],"dc:date.available":["2013-09-10T16:11:48Z"],"dc:date.copyright":["2013"],"dc:date.created":["2013-08-16"],"dc:date.issued":["2013-09-10"],"dc:description.abstract":["The mechanical properties of the transverse carpal ligament (TCL) have yet to be comprehensively measured. Failure strain, failure load, ultimate strength, stiffness and elastic modulus were reported from uniaxial tensile tests. On human cadaveric TCLs, failure strain was significantly higher in female specimens compared to males. Moreover, regional strain analysis showed the lateral end of the tissue to strain significantly more than the medial. Biaxial testing at three different tissue depths was also carried out. Mechanical properties were found to vary significantly by depth with the deeper layers displaying higher mechanical properties. A significant difference with respect to loading direction was also observed with the medial/lateral direction displaying higher mechanical properties than proximal/distal. These results provide mechanical properties which can be incorporated into finite element models or constitutive models of the TCL. Furthermore, this work provides a basis for recommendations for non-invasive treatment options for carpal tunnel syndrome."],"dc:identifier.uri":["http://hdl.handle.net/10214/7496"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["transverse carpal ligament (syn: flexor retunaculum)","carpal tunnel syndrome","biomechanical properties","biaxial testing"],"dc:title":["Biomechanical Properties of the Transverse Carpal Ligament"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:51Z"}