{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/7769"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/7769","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Design and validation of a cadaveric knee joint loading device compatible with magnetic resonance imaging and micro computed tomography","abstract":"Purpose: Design and validation of a magnetic resonance and computed tomography compatible device capable of applying muscle forces to cadaveric knee joints with high precision. Methods: Load was applied to two porcine knee joints at full extension, five and fifteen degrees of flexion. Five repeatability and five reproducibility trials were performed at each flexion angle. Standard deviations (SDs) of joint angle and load were reported. Results: For repeatability, the maximum SDs for joint angle were 1.26° (flexion), 1.54° (ab/adduction) and 0.90° (in/external rotation). The maximum SDs for joint load were 4.60N (anterior/posterior), 7.36N (medial/lateral), and 42.6N (axial). For reproducibility, the maximum SDs for joint angle were 0.84° (flexion), 0.66° (ab/adduction) and 0.92° (in/external rotation). The maximum SDs for joint load were 6.40N (anterior/posterior), 11.7N (medial/lateral), and 39.7N (axial). Conclusions: This level of repeatability/reproducibility is within intra-subject gait variance. Therefore, this device can be an effective tool for in-vitro testing.","abstract_html":"Purpose: Design and validation of a magnetic resonance and computed tomography compatible device capable of applying muscle forces to cadaveric knee joints with high precision. Methods: Load was applied to two porcine knee joints at full extension, five and fifteen degrees of flexion. Five repeatability and five reproducibility trials were performed at each flexion angle. Standard deviations (SDs) of joint angle and load were reported. Results: For repeatability, the maximum SDs for joint angle were 1.26° (flexion), 1.54° (ab/adduction) and 0.90° (in/external rotation). The maximum SDs for joint load were 4.60N (anterior/posterior), 7.36N (medial/lateral), and 42.6N (axial). For reproducibility, the maximum SDs for joint angle were 0.84° (flexion), 0.66° (ab/adduction) and 0.92° (in/external rotation). The maximum SDs for joint load were 6.40N (anterior/posterior), 11.7N (medial/lateral), and 39.7N (axial). Conclusions: This level of repeatability/reproducibility is within intra-subject gait variance. Therefore, this device can be an effective tool for in-vitro testing.","abstract_has_math":false,"creators":["Chen, Larry"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Gordon, Karen"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-01-07","date_published":"2014-01-07","updated_at":"2026-11-19T08:22:32Z","subjects":["orthopaedic biomechanics","medical imaging","in-vitro knee"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/7769","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/7769","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F7769","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gordon, Karen"]},{"key":"dc:creator","label":"Author","values":["Chen, Larry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-07T17:56:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-07T17:56:03Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-12-18"]},{"key":"dc:date.issued","label":"Date","values":["2014-01-07"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["orthopaedic biomechanics","medical imaging","in-vitro knee"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/7769"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: Design and validation of a magnetic resonance and computed tomography compatible device capable of applying muscle forces to cadaveric knee joints with high precision. Methods: Load was applied to two porcine knee joints at full extension, five and fifteen degrees of flexion. Five repeatability and five reproducibility trials were performed at each flexion angle. Standard deviations (SDs) of joint angle and load were reported. Results: For repeatability, the maximum SDs for joint angle were 1.26° (flexion), 1.54° (ab/adduction) and 0.90° (in/external rotation). The maximum SDs for joint load were 4.60N (anterior/posterior), 7.36N (medial/lateral), and 42.6N (axial). For reproducibility, the maximum SDs for joint angle were 0.84° (flexion), 0.66° (ab/adduction) and 0.92° (in/external rotation). The maximum SDs for joint load were 6.40N (anterior/posterior), 11.7N (medial/lateral), and 39.7N (axial). Conclusions: This level of repeatability/reproducibility is within intra-subject gait variance. Therefore, this device can be an effective tool for in-vitro testing."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Canadian Institutes of Health Research"]},{"key":"dc:title","label":"Title","values":["Design and validation of a cadaveric knee joint loading device compatible with magnetic resonance imaging and micro computed tomography"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gordon, Karen"],"dc:creator":["Chen, Larry"],"dc:date.accessioned":["2014-01-07T17:56:03Z"],"dc:date.available":["2014-01-07T17:56:03Z"],"dc:date.copyright":["2013-12"],"dc:date.created":["2013-12-18"],"dc:date.issued":["2014-01-07"],"dc:description.abstract":["Purpose: Design and validation of a magnetic resonance and computed tomography compatible device capable of applying muscle forces to cadaveric knee joints with high precision. Methods: Load was applied to two porcine knee joints at full extension, five and fifteen degrees of flexion. Five repeatability and five reproducibility trials were performed at each flexion angle. Standard deviations (SDs) of joint angle and load were reported. Results: For repeatability, the maximum SDs for joint angle were 1.26° (flexion), 1.54° (ab/adduction) and 0.90° (in/external rotation). The maximum SDs for joint load were 4.60N (anterior/posterior), 7.36N (medial/lateral), and 42.6N (axial). For reproducibility, the maximum SDs for joint angle were 0.84° (flexion), 0.66° (ab/adduction) and 0.92° (in/external rotation). The maximum SDs for joint load were 6.40N (anterior/posterior), 11.7N (medial/lateral), and 39.7N (axial). Conclusions: This level of repeatability/reproducibility is within intra-subject gait variance. Therefore, this device can be an effective tool for in-vitro testing."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Canadian Institutes of Health Research"],"dc:identifier.uri":["http://hdl.handle.net/10214/7769"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["orthopaedic biomechanics","medical imaging","in-vitro knee"],"dc:title":["Design and validation of a cadaveric knee joint loading device compatible with magnetic resonance imaging and micro computed tomography"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:32Z"}