{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/7847"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/7847","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Design and Fabrication of a Piezoresistive Fabric Sensor for Ergonomic Analyses","abstract":"Hand forces are extremely difficult to measure due to the unique interaction they form with complex surfaces. These forces have been linked to an increased risk of developing musculoskeletal disorders even for low forces (2-10 N). Currently available instrumentation does not measure hand forces well on curved surfaces. This thesis presents the design and validation of a flexible piezoresisitive fabric tactile sensor for quantifying hand forces on curved surfaces. Results showed the sensor exhibited a stable, logarithmic calibration curve (R^2 = 0.99) and a high resistance to creep, hysteresis and cyclic loading conditions. Validation testing illustrated a linear calibration relationship (R^2 range = 0.970 – 0.978) with strong correlations between strain gauge and sensor predictions (R^2 range = 0.959 - 0.998), indicating the sensor was an accurate predictor of contact forces applied by the hand.","abstract_html":"Hand forces are extremely difficult to measure due to the unique interaction they form with complex surfaces. These forces have been linked to an increased risk of developing musculoskeletal disorders even for low forces (2-10 N). Currently available instrumentation does not measure hand forces well on curved surfaces. This thesis presents the design and validation of a flexible piezoresisitive fabric tactile sensor for quantifying hand forces on curved surfaces. Results showed the sensor exhibited a stable, logarithmic calibration curve (R^2 = 0.99) and a high resistance to creep, hysteresis and cyclic loading conditions. Validation testing illustrated a linear calibration relationship (R^2 range = 0.970 – 0.978) with strong correlations between strain gauge and sensor predictions (R^2 range = 0.959 - 0.998), indicating the sensor was an accurate predictor of contact forces applied by the hand.","abstract_has_math":false,"creators":["Harris, Luke"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Oliver, Michele","Hayward, Gordon"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-02-03","date_published":"2014-02-03","updated_at":"2026-11-19T08:24:29Z","subjects":["Ergonomics","bioinstrumentation","tactile","sensor","biomechanics","hand forces","engineering"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/7847","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/7847","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F7847","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F7847","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oliver, Michele","Hayward, Gordon"]},{"key":"dc:creator","label":"Author","values":["Harris, Luke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-02-03T14:13:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-02-03T14:13:08Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2014-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-14"]},{"key":"dc:date.issued","label":"Date","values":["2014-02-03"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ergonomics","bioinstrumentation","tactile","sensor","biomechanics","hand forces","engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/7847"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hand forces are extremely difficult to measure due to the unique interaction they form with complex surfaces. These forces have been linked to an increased risk of developing musculoskeletal disorders even for low forces (2-10 N). Currently available instrumentation does not measure hand forces well on curved surfaces. This thesis presents the design and validation of a flexible piezoresisitive fabric tactile sensor for quantifying hand forces on curved surfaces. Results showed the sensor exhibited a stable, logarithmic calibration curve (R^2 = 0.99) and a high resistance to creep, hysteresis and cyclic loading conditions. Validation testing illustrated a linear calibration relationship (R^2 range = 0.970 – 0.978) with strong correlations between strain gauge and sensor predictions (R^2 range = 0.959 - 0.998), indicating the sensor was an accurate predictor of contact forces applied by the hand."]},{"key":"dc:title","label":"Title","values":["Design and Fabrication of a Piezoresistive Fabric Sensor for Ergonomic Analyses"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oliver, Michele","Hayward, Gordon"],"dc:creator":["Harris, Luke"],"dc:date.accessioned":["2014-02-03T14:13:08Z"],"dc:date.available":["2014-02-03T14:13:08Z"],"dc:date.copyright":["2014-01"],"dc:date.created":["2014-01-14"],"dc:date.issued":["2014-02-03"],"dc:description.abstract":["Hand forces are extremely difficult to measure due to the unique interaction they form with complex surfaces. These forces have been linked to an increased risk of developing musculoskeletal disorders even for low forces (2-10 N). Currently available instrumentation does not measure hand forces well on curved surfaces. This thesis presents the design and validation of a flexible piezoresisitive fabric tactile sensor for quantifying hand forces on curved surfaces. Results showed the sensor exhibited a stable, logarithmic calibration curve (R^2 = 0.99) and a high resistance to creep, hysteresis and cyclic loading conditions. Validation testing illustrated a linear calibration relationship (R^2 range = 0.970 – 0.978) with strong correlations between strain gauge and sensor predictions (R^2 range = 0.959 - 0.998), indicating the sensor was an accurate predictor of contact forces applied by the hand."],"dc:identifier.uri":["http://hdl.handle.net/10214/7847"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["Ergonomics","bioinstrumentation","tactile","sensor","biomechanics","hand forces","engineering"],"dc:title":["Design and Fabrication of a Piezoresistive Fabric Sensor for Ergonomic Analyses"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:29Z"}