{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/8028"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/8028","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Numerical Modelling of Fluidelastic Instability in a Normal Triangle Tube Array","abstract":"Flow Induced Vibrations (FIV) are a significant threat to the life of major power plant components such as heat exchangers. The most dangerous of these excitation sources is fluidelastic instability (FEI). Early FEI models focused on predicting the stability threshold of heat exchanger tubes subjected to fluidelastic forces based on empirical data, but the inability of empirical predictions to account for the variability in tube array geometry, pitch, and single or two phase flow limited the usefulness of these models. This thesis investigates the properties of unsteady flow in a normal triangle tube array with a pitch-to-diameter ratio of 1.5. Stability simulations are conducted over a mass damping parameter range 9--200, using a reduced order model of the moving tube. This investigation provides a direct observation of the channel area. When implemented into the time domain model the new parameters provide better agreement with the experimental stability threshold data available.","abstract_html":"Flow Induced Vibrations (FIV) are a significant threat to the life of major power plant components such as heat exchangers. The most dangerous of these excitation sources is fluidelastic instability (FEI). Early FEI models focused on predicting the stability threshold of heat exchanger tubes subjected to fluidelastic forces based on empirical data, but the inability of empirical predictions to account for the variability in tube array geometry, pitch, and single or two phase flow limited the usefulness of these models. This thesis investigates the properties of unsteady flow in a normal triangle tube array with a pitch-to-diameter ratio of 1.5. Stability simulations are conducted over a mass damping parameter range 9--200, using a reduced order model of the moving tube. This investigation provides a direct observation of the channel area. When implemented into the time domain model the new parameters provide better agreement with the experimental stability threshold data available.","abstract_has_math":false,"creators":["El Bouzidi, Salim"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Hassan, Marwan"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-04-29","date_published":"2014-04-29","updated_at":"2026-11-19T08:24:39Z","subjects":["vibrations","flow induced vibration","steam generators","fluidelastic instability","numerical modelling","time delay","flow cell model"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/8028","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/8028","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F8028","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hassan, Marwan"]},{"key":"dc:creator","label":"Author","values":["El Bouzidi, Salim"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-04-29T19:05:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-04-29T19:05:04Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2014-04"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-04-23"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-29"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["vibrations","flow induced vibration","steam generators","fluidelastic instability","numerical modelling","time delay","flow cell model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/8028"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Flow Induced Vibrations (FIV) are a significant threat to the life of major power plant components such as heat exchangers. The most dangerous of these excitation sources is fluidelastic instability (FEI). Early FEI models focused on predicting the stability threshold of heat exchanger tubes subjected to fluidelastic forces based on empirical data, but the inability of empirical predictions to account for the variability in tube array geometry, pitch, and single or two phase flow limited the usefulness of these models. This thesis investigates the properties of unsteady flow in a normal triangle tube array with a pitch-to-diameter ratio of 1.5. Stability simulations are conducted over a mass damping parameter range 9--200, using a reduced order model of the moving tube. This investigation provides a direct observation of the channel area. When implemented into the time domain model the new parameters provide better agreement with the experimental stability threshold data available."]},{"key":"dc:title","label":"Title","values":["Numerical Modelling of Fluidelastic Instability in a Normal Triangle Tube Array"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hassan, Marwan"],"dc:creator":["El Bouzidi, Salim"],"dc:date.accessioned":["2014-04-29T19:05:04Z"],"dc:date.available":["2014-04-29T19:05:04Z"],"dc:date.copyright":["2014-04"],"dc:date.created":["2014-04-23"],"dc:date.issued":["2014-04-29"],"dc:description.abstract":["Flow Induced Vibrations (FIV) are a significant threat to the life of major power plant components such as heat exchangers. The most dangerous of these excitation sources is fluidelastic instability (FEI). Early FEI models focused on predicting the stability threshold of heat exchanger tubes subjected to fluidelastic forces based on empirical data, but the inability of empirical predictions to account for the variability in tube array geometry, pitch, and single or two phase flow limited the usefulness of these models. This thesis investigates the properties of unsteady flow in a normal triangle tube array with a pitch-to-diameter ratio of 1.5. Stability simulations are conducted over a mass damping parameter range 9--200, using a reduced order model of the moving tube. This investigation provides a direct observation of the channel area. When implemented into the time domain model the new parameters provide better agreement with the experimental stability threshold data available."],"dc:identifier.uri":["http://hdl.handle.net/10214/8028"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["vibrations","flow induced vibration","steam generators","fluidelastic instability","numerical modelling","time delay","flow cell model"],"dc:title":["Numerical Modelling of Fluidelastic Instability in a Normal Triangle Tube Array"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:39Z"}