{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/8328"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/8328","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Reclamation of Vegetable Processing Wastewater with a Sequencing Batch Reactor","abstract":"An investigation was completed for nutrient and organic loading removal from vegetable processing wastewater. Vegetable processing wastewater was collected from two industrial partners. The sequencing batch reactor was selected as the treatment technology due to its versatility, with the system HRT chosen as the varying parameter to be tested. It was determined that the optimal conditions for organic loading and nutrient removal for Industrial Partner 1 was 2.5 h of aeration and 1.0 L, which equates to 20% of liquid exchange with a HRT of 30 h, obtaining removal efficiencies of 95%, 79% and 75% for COD, TKN and TP respectively. Confirmation studies were completed with Industrial Partner 2. Similar operational characteristics were used, but different removal efficiencies were obtained, confirming the need to optimize the process for every application. UV disinfection was also used for microbial removal for onsite water reuse.","abstract_html":"An investigation was completed for nutrient and organic loading removal from vegetable processing wastewater. Vegetable processing wastewater was collected from two industrial partners. The sequencing batch reactor was selected as the treatment technology due to its versatility, with the system HRT chosen as the varying parameter to be tested. It was determined that the optimal conditions for organic loading and nutrient removal for Industrial Partner 1 was 2.5 h of aeration and 1.0 L, which equates to 20% of liquid exchange with a HRT of 30 h, obtaining removal efficiencies of 95%, 79% and 75% for COD, TKN and TP respectively. Confirmation studies were completed with Industrial Partner 2. Similar operational characteristics were used, but different removal efficiencies were obtained, confirming the need to optimize the process for every application. UV disinfection was also used for microbial removal for onsite water reuse.","abstract_has_math":false,"creators":["Lam, Ka Yee"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Zytner, Richard"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-08-25","date_published":"2014-08-25","updated_at":"2026-11-19T08:26:33Z","subjects":["Sequencing Batch Reactor","Vegetable Processing Wastewater","Nutrient","Total Phosphorus","Total Kjeldahl Nitrogen"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10214/8328","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10214/8328","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F8328","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zytner, Richard"]},{"key":"dc:creator","label":"Author","values":["Lam, Ka Yee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-08-25T18:34:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-08-25T18:34:26Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2014-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-08-18"]},{"key":"dc:date.issued","label":"Date","values":["2014-08-25"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sequencing Batch Reactor","Vegetable Processing Wastewater","Nutrient","Total Phosphorus","Total Kjeldahl Nitrogen"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/8328"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An investigation was completed for nutrient and organic loading removal from vegetable processing wastewater. Vegetable processing wastewater was collected from two industrial partners. The sequencing batch reactor was selected as the treatment technology due to its versatility, with the system HRT chosen as the varying parameter to be tested. It was determined that the optimal conditions for organic loading and nutrient removal for Industrial Partner 1 was 2.5 h of aeration and 1.0 L, which equates to 20% of liquid exchange with a HRT of 30 h, obtaining removal efficiencies of 95%, 79% and 75% for COD, TKN and TP respectively. Confirmation studies were completed with Industrial Partner 2. Similar operational characteristics were used, but different removal efficiencies were obtained, confirming the need to optimize the process for every application. UV disinfection was also used for microbial removal for onsite water reuse."]},{"key":"dc:title","label":"Title","values":["Reclamation of Vegetable Processing Wastewater with a Sequencing Batch Reactor"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zytner, Richard"],"dc:creator":["Lam, Ka Yee"],"dc:date.accessioned":["2014-08-25T18:34:26Z"],"dc:date.available":["2014-08-25T18:34:26Z"],"dc:date.copyright":["2014-08"],"dc:date.created":["2014-08-18"],"dc:date.issued":["2014-08-25"],"dc:description.abstract":["An investigation was completed for nutrient and organic loading removal from vegetable processing wastewater. Vegetable processing wastewater was collected from two industrial partners. The sequencing batch reactor was selected as the treatment technology due to its versatility, with the system HRT chosen as the varying parameter to be tested. It was determined that the optimal conditions for organic loading and nutrient removal for Industrial Partner 1 was 2.5 h of aeration and 1.0 L, which equates to 20% of liquid exchange with a HRT of 30 h, obtaining removal efficiencies of 95%, 79% and 75% for COD, TKN and TP respectively. Confirmation studies were completed with Industrial Partner 2. Similar operational characteristics were used, but different removal efficiencies were obtained, confirming the need to optimize the process for every application. UV disinfection was also used for microbial removal for onsite water reuse."],"dc:identifier.uri":["http://hdl.handle.net/10214/8328"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["Sequencing Batch Reactor","Vegetable Processing Wastewater","Nutrient","Total Phosphorus","Total Kjeldahl Nitrogen"],"dc:title":["Reclamation of Vegetable Processing Wastewater with a Sequencing Batch Reactor"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:33Z"}