{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/8679"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/8679","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Effectiveness of Suction Lysimeters in Determining Contaminant Transport Within Leaching Bed Systems","abstract":"The rising importance of groundwater as a useable water source has led to a greater emphasis on its potential for contamination, with leaching bed systems being one of the major sources of potential contaminants. Research was completed to determine the effectiveness of using suction lysimeters to determine if leaching beds are functioning as intended with respect to chemical contaminants (TKN, nitrate, nitrite) and biological contaminants (Escherichia coli). Results from lab and leaching bed experiments indicate that suction lysimeters can be used to successfully track chemical contaminants but cannot be successfully used for tracking biological contaminants. This research has demonstrated that suction lysimeters are a useful method for determining some aspects of the functionality of leaching bed systems. Further research on and development of suction lysimeters and leaching bed systems is needed to better understand of how to accurately track contamination from these systems.","abstract_html":"The rising importance of groundwater as a useable water source has led to a greater emphasis on its potential for contamination, with leaching bed systems being one of the major sources of potential contaminants. Research was completed to determine the effectiveness of using suction lysimeters to determine if leaching beds are functioning as intended with respect to chemical contaminants (TKN, nitrate, nitrite) and biological contaminants (Escherichia coli). Results from lab and leaching bed experiments indicate that suction lysimeters can be used to successfully track chemical contaminants but cannot be successfully used for tracking biological contaminants. This research has demonstrated that suction lysimeters are a useful method for determining some aspects of the functionality of leaching bed systems. Further research on and development of suction lysimeters and leaching bed systems is needed to better understand of how to accurately track contamination from these systems.","abstract_has_math":false,"creators":["Weaver, Colin"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Joy, Douglas"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-01-07","date_published":"2015-01-07","updated_at":"2026-11-19T08:20:51Z","subjects":["suction lysimeter","leaching bed","septic system","on-site system","E. coli","groundwater"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/8679","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/8679","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F8679","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joy, Douglas"]},{"key":"dc:creator","label":"Author","values":["Weaver, Colin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-07T21:08:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-07T21:08:10Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2014-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-12-22"]},{"key":"dc:date.issued","label":"Date","values":["2015-01-07"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["suction lysimeter","leaching bed","septic system","on-site system","E. coli","groundwater"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/8679"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The rising importance of groundwater as a useable water source has led to a greater emphasis on its potential for contamination, with leaching bed systems being one of the major sources of potential contaminants. Research was completed to determine the effectiveness of using suction lysimeters to determine if leaching beds are functioning as intended with respect to chemical contaminants (TKN, nitrate, nitrite) and biological contaminants (Escherichia coli). Results from lab and leaching bed experiments indicate that suction lysimeters can be used to successfully track chemical contaminants but cannot be successfully used for tracking biological contaminants. This research has demonstrated that suction lysimeters are a useful method for determining some aspects of the functionality of leaching bed systems. Further research on and development of suction lysimeters and leaching bed systems is needed to better understand of how to accurately track contamination from these systems."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Ministry of Municipal Affairs and Housing","University of Guelph"]},{"key":"dc:title","label":"Title","values":["Effectiveness of Suction Lysimeters in Determining Contaminant Transport Within Leaching Bed Systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joy, Douglas"],"dc:creator":["Weaver, Colin"],"dc:date.accessioned":["2015-01-07T21:08:10Z"],"dc:date.available":["2015-01-07T21:08:10Z"],"dc:date.copyright":["2014-12"],"dc:date.created":["2014-12-22"],"dc:date.issued":["2015-01-07"],"dc:description.abstract":["The rising importance of groundwater as a useable water source has led to a greater emphasis on its potential for contamination, with leaching bed systems being one of the major sources of potential contaminants. Research was completed to determine the effectiveness of using suction lysimeters to determine if leaching beds are functioning as intended with respect to chemical contaminants (TKN, nitrate, nitrite) and biological contaminants (Escherichia coli). Results from lab and leaching bed experiments indicate that suction lysimeters can be used to successfully track chemical contaminants but cannot be successfully used for tracking biological contaminants. This research has demonstrated that suction lysimeters are a useful method for determining some aspects of the functionality of leaching bed systems. Further research on and development of suction lysimeters and leaching bed systems is needed to better understand of how to accurately track contamination from these systems."],"dc:description.sponsorship":["Ontario Ministry of Municipal Affairs and Housing","University of Guelph"],"dc:identifier.uri":["http://hdl.handle.net/10214/8679"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["suction lysimeter","leaching bed","septic system","on-site system","E. coli","groundwater"],"dc:title":["Effectiveness of Suction Lysimeters in Determining Contaminant Transport Within Leaching Bed Systems"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:20:51Z"}