{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9071"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9071","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Detection of Foodborne Biohazards Using Antibody Modified Electrospun Conducting Fibres","abstract":"The objective of the research was to fabricate an integrated sensor that could detect Escherichia coli K-12 from sample matrices. The sensor was based on antibodies immobilized on the surface of conducting polymer coated electrospun nylon fibres. Baseline studies optimized the conditions required for consistent depositions of polyaniline on the surface of nylon fibres. Antibodies with affinity towards E. coli K-12 were coupled to the conducting polymer and binding of the bacterium was followed using impedance spectroscopy using a 4-electrode configuration. It was demonstrated that the sensor membrane could recover >80% E. coli K-12 when placed in suspensions containing 1 – 5 log CFU E. coli K-12. In terms of detection, the increase in charge transfer resistance could be correlated to cell density of E. coli within the range of 1-6 log CFU. The study provides a proof of an integrated capture and label-free detection method for microbial targets.","abstract_html":"The objective of the research was to fabricate an integrated sensor that could detect Escherichia coli K-12 from sample matrices. The sensor was based on antibodies immobilized on the surface of conducting polymer coated electrospun nylon fibres. Baseline studies optimized the conditions required for consistent depositions of polyaniline on the surface of nylon fibres. Antibodies with affinity towards E. coli K-12 were coupled to the conducting polymer and binding of the bacterium was followed using impedance spectroscopy using a 4-electrode configuration. It was demonstrated that the sensor membrane could recover &gt;80% E. coli K-12 when placed in suspensions containing 1 – 5 log CFU E. coli K-12. In terms of detection, the increase in charge transfer resistance could be correlated to cell density of E. coli within the range of 1-6 log CFU. The study provides a proof of an integrated capture and label-free detection method for microbial targets.","abstract_has_math":false,"creators":["Saha, Tamalika"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Food Science","school":null,"contributors":[],"advisors":["Warriner, Keith"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-08-14","date_published":"2015-08-14","updated_at":"2026-11-19T08:23:20Z","subjects":["Biosensor","label-free immunosensor","electrospining","nylon 6","polyaniline","immobilization","E. coli"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9071","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9071","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F9071","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9071","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Warriner, Keith"]},{"key":"dc:creator","label":"Author","values":["Saha, Tamalika"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-08-14T16:15:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-08-14T16:15:50Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-05-15"]},{"key":"dc:date.issued","label":"Date","values":["2015-08-14"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Food Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Food Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biosensor","label-free immunosensor","electrospining","nylon 6","polyaniline","immobilization","E. coli"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9071"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of the research was to fabricate an integrated sensor that could detect Escherichia coli K-12 from sample matrices. The sensor was based on antibodies immobilized on the surface of conducting polymer coated electrospun nylon fibres. Baseline studies optimized the conditions required for consistent depositions of polyaniline on the surface of nylon fibres. Antibodies with affinity towards E. coli K-12 were coupled to the conducting polymer and binding of the bacterium was followed using impedance spectroscopy using a 4-electrode configuration. It was demonstrated that the sensor membrane could recover >80% E. coli K-12 when placed in suspensions containing 1 – 5 log CFU E. coli K-12. In terms of detection, the increase in charge transfer resistance could be correlated to cell density of E. coli within the range of 1-6 log CFU. The study provides a proof of an integrated capture and label-free detection method for microbial targets."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Ministry of Agriculture, Food and Rural Affairs"]},{"key":"dc:title","label":"Title","values":["Detection of Foodborne Biohazards Using Antibody Modified Electrospun Conducting Fibres"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Warriner, Keith"],"dc:creator":["Saha, Tamalika"],"dc:date.accessioned":["2015-08-14T16:15:50Z"],"dc:date.available":["2015-08-14T16:15:50Z"],"dc:date.copyright":["2015-05"],"dc:date.created":["2015-05-15"],"dc:date.issued":["2015-08-14"],"dc:description.abstract":["The objective of the research was to fabricate an integrated sensor that could detect Escherichia coli K-12 from sample matrices. The sensor was based on antibodies immobilized on the surface of conducting polymer coated electrospun nylon fibres. Baseline studies optimized the conditions required for consistent depositions of polyaniline on the surface of nylon fibres. Antibodies with affinity towards E. coli K-12 were coupled to the conducting polymer and binding of the bacterium was followed using impedance spectroscopy using a 4-electrode configuration. It was demonstrated that the sensor membrane could recover >80% E. coli K-12 when placed in suspensions containing 1 – 5 log CFU E. coli K-12. In terms of detection, the increase in charge transfer resistance could be correlated to cell density of E. coli within the range of 1-6 log CFU. The study provides a proof of an integrated capture and label-free detection method for microbial targets."],"dc:description.sponsorship":["Ontario Ministry of Agriculture, Food and Rural Affairs"],"dc:identifier.uri":["http://hdl.handle.net/10214/9071"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["Biosensor","label-free immunosensor","electrospining","nylon 6","polyaniline","immobilization","E. coli"],"dc:title":["Detection of Foodborne Biohazards Using Antibody Modified Electrospun Conducting Fibres"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Food Science"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Food Science"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:23:20Z"}