{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9150"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9150","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"On the Effects of Resolution on APXS-GUAPX Analytical Results: From Spectrum to Peak Areas to Concentration Estimates","abstract":"The thesis presents an in-depth investigation into the effects of spectral resolution on Alpha Particle X-ray Spectrometer (APXS) measurements processed using the GUAPX fitting code. The APXS analytical results contribute to understanding rock and soil types on Mars and the processes by which they formed. However, mission constraints, including instrumental degradation due to neutron damage and limited temperature control, mean that instrumental resolution cannot always be optimized. A methodology was developed using ratios of relevant analytical results to characterize the relationship between estimated peak areas, concentration estimates, and resolution. A differential effect favouring the heavier element concentration estimates with worsening resolution was observed and the underlying causes identified. The link between relative change in FWHM and concentration estimates was quantified for ten geochemical elements. Lastly, it was found that variations in estimated concentrations can fall outside precision error over resolution and concentration ranges similar to those seen on Mars.","abstract_html":"The thesis presents an in-depth investigation into the effects of spectral resolution on Alpha Particle X-ray Spectrometer (APXS) measurements processed using the GUAPX fitting code. The APXS analytical results contribute to understanding rock and soil types on Mars and the processes by which they formed. However, mission constraints, including instrumental degradation due to neutron damage and limited temperature control, mean that instrumental resolution cannot always be optimized. A methodology was developed using ratios of relevant analytical results to characterize the relationship between estimated peak areas, concentration estimates, and resolution. A differential effect favouring the heavier element concentration estimates with worsening resolution was observed and the underlying causes identified. The link between relative change in FWHM and concentration estimates was quantified for ten geochemical elements. Lastly, it was found that variations in estimated concentrations can fall outside precision error over resolution and concentration ranges similar to those seen on Mars.","abstract_has_math":false,"creators":["Pardo, Renato"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Campbell, John L. (Iain)","Gellert, Ralf"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-04","date_published":"2015-09-04","updated_at":"2026-11-19T08:26:04Z","subjects":["Spectroscopy","Resolution","APXS","Alpha Particle X-Ray Spectrometer","X-Ray"],"languages":["en"],"rights":["Attribution-NonCommercial-ShareAlike 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-sa/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9150","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9150","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9150","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Campbell, John L. (Iain)","Gellert, Ralf"]},{"key":"dc:creator","label":"Author","values":["Pardo, Renato"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-04T15:26:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-04T15:26:27Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015-07"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-07-14"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spectroscopy","Resolution","APXS","Alpha Particle X-Ray Spectrometer","X-Ray"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-ShareAlike 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-sa/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9150"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The thesis presents an in-depth investigation into the effects of spectral resolution on Alpha Particle X-ray Spectrometer (APXS) measurements processed using the GUAPX fitting code. The APXS analytical results contribute to understanding rock and soil types on Mars and the processes by which they formed. However, mission constraints, including instrumental degradation due to neutron damage and limited temperature control, mean that instrumental resolution cannot always be optimized. A methodology was developed using ratios of relevant analytical results to characterize the relationship between estimated peak areas, concentration estimates, and resolution. A differential effect favouring the heavier element concentration estimates with worsening resolution was observed and the underlying causes identified. The link between relative change in FWHM and concentration estimates was quantified for ten geochemical elements. Lastly, it was found that variations in estimated concentrations can fall outside precision error over resolution and concentration ranges similar to those seen on Mars."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Canadian Space Agency"]},{"key":"dc:title","label":"Title","values":["On the Effects of Resolution on APXS-GUAPX Analytical Results: From Spectrum to Peak Areas to Concentration Estimates"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Campbell, John L. (Iain)","Gellert, Ralf"],"dc:creator":["Pardo, Renato"],"dc:date.accessioned":["2015-09-04T15:26:27Z"],"dc:date.available":["2015-09-04T15:26:27Z"],"dc:date.copyright":["2015-07"],"dc:date.created":["2015-07-14"],"dc:date.issued":["2015-09-04"],"dc:description.abstract":["The thesis presents an in-depth investigation into the effects of spectral resolution on Alpha Particle X-ray Spectrometer (APXS) measurements processed using the GUAPX fitting code. The APXS analytical results contribute to understanding rock and soil types on Mars and the processes by which they formed. However, mission constraints, including instrumental degradation due to neutron damage and limited temperature control, mean that instrumental resolution cannot always be optimized. A methodology was developed using ratios of relevant analytical results to characterize the relationship between estimated peak areas, concentration estimates, and resolution. A differential effect favouring the heavier element concentration estimates with worsening resolution was observed and the underlying causes identified. The link between relative change in FWHM and concentration estimates was quantified for ten geochemical elements. Lastly, it was found that variations in estimated concentrations can fall outside precision error over resolution and concentration ranges similar to those seen on Mars."],"dc:description.sponsorship":["Canadian Space Agency"],"dc:identifier.uri":["http://hdl.handle.net/10214/9150"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-ShareAlike 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-sa/2.5/ca/"],"dc:subject":["Spectroscopy","Resolution","APXS","Alpha Particle X-Ray Spectrometer","X-Ray"],"dc:title":["On the Effects of Resolution on APXS-GUAPX Analytical Results: From Spectrum to Peak Areas to Concentration Estimates"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:04Z"}