{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9219"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9219","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Assessment of capsule endoscopy technology as an imaging tool for the equine small intestine","abstract":"Capsule endoscopy (CE), in which an encapsulated camera is ingested, is used in human medicine to image the small intestine (SI) to aid in the diagnosis of intestinal disorders by detecting lesions, inflammation, bleeding, and tumors. The broad objective of this study was to assess the value of using the MiroCam capsule endoscope in horses. Duration of recording and image quality were assessed in two healthy Standardbred horses that each underwent four CE examinations. Good quality video segments were obtained, demonstrating SI features including distinct villi, mucosal lesions and luminal parasites. However, image transmission was intermittent and of short duration (0.5 to 82.41 minutes) and images were frequently obstructed by residual feed particles. This pilot study demonstrates the potential utility of CE to aid in diagnosis of SI conditions, however further research into signal transmission and equine fasting protocols is required before CE can be effectively used in equine medicine.","abstract_html":"Capsule endoscopy (CE), in which an encapsulated camera is ingested, is used in human medicine to image the small intestine (SI) to aid in the diagnosis of intestinal disorders by detecting lesions, inflammation, bleeding, and tumors. The broad objective of this study was to assess the value of using the MiroCam capsule endoscope in horses. Duration of recording and image quality were assessed in two healthy Standardbred horses that each underwent four CE examinations. Good quality video segments were obtained, demonstrating SI features including distinct villi, mucosal lesions and luminal parasites. However, image transmission was intermittent and of short duration (0.5 to 82.41 minutes) and images were frequently obstructed by residual feed particles. This pilot study demonstrates the potential utility of CE to aid in diagnosis of SI conditions, however further research into signal transmission and equine fasting protocols is required before CE can be effectively used in equine medicine.","abstract_has_math":false,"creators":["Gibbard, Diane"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Biomedical Sciences","school":null,"contributors":[],"advisors":["Thomason, Jeffrey"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-10","date_published":"2015-09-10","updated_at":"2026-11-19T08:24:24Z","subjects":["wireless capsule endoscopy","small intestine","equine","digestive tract","imaging"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9219","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9219","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F9219","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9219","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Thomason, Jeffrey"]},{"key":"dc:creator","label":"Author","values":["Gibbard, Diane"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-10T16:58:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-01T05:00:15Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-08-19"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Biomedical Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["wireless capsule endoscopy","small intestine","equine","digestive tract","imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9219"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Capsule endoscopy (CE), in which an encapsulated camera is ingested, is used in human medicine to image the small intestine (SI) to aid in the diagnosis of intestinal disorders by detecting lesions, inflammation, bleeding, and tumors. The broad objective of this study was to assess the value of using the MiroCam capsule endoscope in horses. Duration of recording and image quality were assessed in two healthy Standardbred horses that each underwent four CE examinations. Good quality video segments were obtained, demonstrating SI features including distinct villi, mucosal lesions and luminal parasites. However, image transmission was intermittent and of short duration (0.5 to 82.41 minutes) and images were frequently obstructed by residual feed particles. This pilot study demonstrates the potential utility of CE to aid in diagnosis of SI conditions, however further research into signal transmission and equine fasting protocols is required before CE can be effectively used in equine medicine."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Equine Guelph","University of Guelph"]},{"key":"dc:title","label":"Title","values":["Assessment of capsule endoscopy technology as an imaging tool for the equine small intestine"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Thomason, Jeffrey"],"dc:creator":["Gibbard, Diane"],"dc:date.accessioned":["2015-09-10T16:58:30Z"],"dc:date.available":["2016-05-01T05:00:15Z"],"dc:date.copyright":["2015-08"],"dc:date.created":["2015-08-19"],"dc:date.issued":["2015-09-10"],"dc:description.abstract":["Capsule endoscopy (CE), in which an encapsulated camera is ingested, is used in human medicine to image the small intestine (SI) to aid in the diagnosis of intestinal disorders by detecting lesions, inflammation, bleeding, and tumors. The broad objective of this study was to assess the value of using the MiroCam capsule endoscope in horses. Duration of recording and image quality were assessed in two healthy Standardbred horses that each underwent four CE examinations. Good quality video segments were obtained, demonstrating SI features including distinct villi, mucosal lesions and luminal parasites. However, image transmission was intermittent and of short duration (0.5 to 82.41 minutes) and images were frequently obstructed by residual feed particles. This pilot study demonstrates the potential utility of CE to aid in diagnosis of SI conditions, however further research into signal transmission and equine fasting protocols is required before CE can be effectively used in equine medicine."],"dc:description.sponsorship":["Equine Guelph","University of Guelph"],"dc:identifier.uri":["http://hdl.handle.net/10214/9219"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["wireless capsule endoscopy","small intestine","equine","digestive tract","imaging"],"dc:title":["Assessment of capsule endoscopy technology as an imaging tool for the equine small intestine"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Biomedical Sciences"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Biomedical Sciences"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:24Z"}