{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9250"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9250","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Analysis of 3D Strain in the Human Medial Meniscus and Comparison to 3D Strain in Meniscal Allograft Transplants","abstract":"A method of measuring 3D strain in-vitro is presented. Regional 3D meniscal strain has not been studied in a large number of human knees under simulated physiological loading. Strain is calculated by tracking markers implanted within the meniscal tissue using computed tomography imaging under simulated physiologically relevant loading. No statistically significant difference between strain in the middle or posterior of the meniscus or between the principal directions of strain is uncovered. Strain in meniscal allograft transplants (MAT) is also evaluated with two surgical fixation techniques; both techniques use soft tissue anterior and posterior root fixation via transosseous suture but one also includes a third peripheral transosseous suture fixation. No significant difference was found. These results suggest that postoperative MAT perform in a similar manner to the native meniscus, and the addition of a peripheral anchor may not be necessary to replicate native tissue strain or improve the chondroprotective effect.","abstract_html":"A method of measuring 3D strain in-vitro is presented. Regional 3D meniscal strain has not been studied in a large number of human knees under simulated physiological loading. Strain is calculated by tracking markers implanted within the meniscal tissue using computed tomography imaging under simulated physiologically relevant loading. No statistically significant difference between strain in the middle or posterior of the meniscus or between the principal directions of strain is uncovered. Strain in meniscal allograft transplants (MAT) is also evaluated with two surgical fixation techniques; both techniques use soft tissue anterior and posterior root fixation via transosseous suture but one also includes a third peripheral transosseous suture fixation. No significant difference was found. These results suggest that postoperative MAT perform in a similar manner to the native meniscus, and the addition of a peripheral anchor may not be necessary to replicate native tissue strain or improve the chondroprotective effect.","abstract_has_math":false,"creators":["Kolaczek, Sandra"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Gordon, Karen","Hurtig, Mark"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-17","date_published":"2015-09-17","updated_at":"2026-11-19T08:27:43Z","subjects":["Meniscus","Strain","Soft Tissue Biomechanics","Meniscal Allograft Transplant"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9250","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9250","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9250","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gordon, Karen","Hurtig, Mark"]},{"key":"dc:creator","label":"Author","values":["Kolaczek, Sandra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-17T14:40:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-17T14:40:37Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-09-08"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-17"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Meniscus","Strain","Soft Tissue Biomechanics","Meniscal Allograft Transplant"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9250"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A method of measuring 3D strain in-vitro is presented. Regional 3D meniscal strain has not been studied in a large number of human knees under simulated physiological loading. Strain is calculated by tracking markers implanted within the meniscal tissue using computed tomography imaging under simulated physiologically relevant loading. No statistically significant difference between strain in the middle or posterior of the meniscus or between the principal directions of strain is uncovered. Strain in meniscal allograft transplants (MAT) is also evaluated with two surgical fixation techniques; both techniques use soft tissue anterior and posterior root fixation via transosseous suture but one also includes a third peripheral transosseous suture fixation. No significant difference was found. These results suggest that postoperative MAT perform in a similar manner to the native meniscus, and the addition of a peripheral anchor may not be necessary to replicate native tissue strain or improve the chondroprotective effect."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Musculoskeletal Transplant Foundation","Canadian Institutes of Health Research"]},{"key":"dc:title","label":"Title","values":["Analysis of 3D Strain in the Human Medial Meniscus and Comparison to 3D Strain in Meniscal Allograft Transplants"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gordon, Karen","Hurtig, Mark"],"dc:creator":["Kolaczek, Sandra"],"dc:date.accessioned":["2015-09-17T14:40:37Z"],"dc:date.available":["2015-09-17T14:40:37Z"],"dc:date.copyright":["2015"],"dc:date.created":["2015-09-08"],"dc:date.issued":["2015-09-17"],"dc:description.abstract":["A method of measuring 3D strain in-vitro is presented. Regional 3D meniscal strain has not been studied in a large number of human knees under simulated physiological loading. Strain is calculated by tracking markers implanted within the meniscal tissue using computed tomography imaging under simulated physiologically relevant loading. No statistically significant difference between strain in the middle or posterior of the meniscus or between the principal directions of strain is uncovered. Strain in meniscal allograft transplants (MAT) is also evaluated with two surgical fixation techniques; both techniques use soft tissue anterior and posterior root fixation via transosseous suture but one also includes a third peripheral transosseous suture fixation. No significant difference was found. These results suggest that postoperative MAT perform in a similar manner to the native meniscus, and the addition of a peripheral anchor may not be necessary to replicate native tissue strain or improve the chondroprotective effect."],"dc:description.sponsorship":["Musculoskeletal Transplant Foundation","Canadian Institutes of Health Research"],"dc:identifier.uri":["http://hdl.handle.net/10214/9250"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["Meniscus","Strain","Soft Tissue Biomechanics","Meniscal Allograft Transplant"],"dc:title":["Analysis of 3D Strain in the Human Medial Meniscus and Comparison to 3D Strain in Meniscal Allograft Transplants"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:43Z"}