{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9337"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9337","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"An Analytical Approach for Compton-Rayleigh Scatter Peak Analysis for the Mars Science Laboratory Alpha Particle X-ray Spectrometer","abstract":"As part of a suite of complimentary science instruments onboard the Mars Science Laboratory rover, the alpha particle X-ray spectrometer (APXS) determines the chemical abundances of Martian rocks and soils for elements from Na to Y via particle induced X-ray emission and X-ray fluorescence. Due to attenuation effects, elements with Z < 11 cannot be directly detected. These invisible components can be quantified indirectly by the Compton-Rayleigh scatter-peaks in APXS spectra. This thesis focuses on the development of an analytical simulation program (CRAM) used to predict the Compton-Rayleigh ratio (C/R) for APXS spectra in a more timely manner than the existing Monte Carlo method (MarsGeom). The simulated C/R, when related to the experimental C/R, is used to quantify any excess or deficit of invisible components in APXS targets. The results of CRAM are compared to MarsGeom and both datasets agree, giving a limit of invisible component detection of approximately 5 wt%.","abstract_html":"As part of a suite of complimentary science instruments onboard the Mars Science Laboratory rover, the alpha particle X-ray spectrometer (APXS) determines the chemical abundances of Martian rocks and soils for elements from Na to Y via particle induced X-ray emission and X-ray fluorescence. Due to attenuation effects, elements with Z &lt; 11 cannot be directly detected. These invisible components can be quantified indirectly by the Compton-Rayleigh scatter-peaks in APXS spectra. This thesis focuses on the development of an analytical simulation program (CRAM) used to predict the Compton-Rayleigh ratio (C/R) for APXS spectra in a more timely manner than the existing Monte Carlo method (MarsGeom). The simulated C/R, when related to the experimental C/R, is used to quantify any excess or deficit of invisible components in APXS targets. The results of CRAM are compared to MarsGeom and both datasets agree, giving a limit of invisible component detection of approximately 5 wt%.","abstract_has_math":false,"creators":["Tesselaar, Dustin"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Gellert, Ralf"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-11-20","date_published":"2015-11-20","updated_at":"2026-11-19T08:23:13Z","subjects":["Compton Scattering","Rayleigh Scattering","Physics","APXS","Alpha Particle X-ray Spectrometer","XRF","PIXE"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9337","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9337","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F9337","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9337","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gellert, Ralf"]},{"key":"dc:creator","label":"Author","values":["Tesselaar, Dustin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-11-20T18:53:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-25T05:00:16Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-09-25"]},{"key":"dc:date.issued","label":"Date","values":["2015-11-20"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Compton Scattering","Rayleigh Scattering","Physics","APXS","Alpha Particle X-ray Spectrometer","XRF","PIXE"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9337"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As part of a suite of complimentary science instruments onboard the Mars Science Laboratory rover, the alpha particle X-ray spectrometer (APXS) determines the chemical abundances of Martian rocks and soils for elements from Na to Y via particle induced X-ray emission and X-ray fluorescence. Due to attenuation effects, elements with Z < 11 cannot be directly detected. These invisible components can be quantified indirectly by the Compton-Rayleigh scatter-peaks in APXS spectra. This thesis focuses on the development of an analytical simulation program (CRAM) used to predict the Compton-Rayleigh ratio (C/R) for APXS spectra in a more timely manner than the existing Monte Carlo method (MarsGeom). The simulated C/R, when related to the experimental C/R, is used to quantify any excess or deficit of invisible components in APXS targets. The results of CRAM are compared to MarsGeom and both datasets agree, giving a limit of invisible component detection of approximately 5 wt%."]},{"key":"dc:title","label":"Title","values":["An Analytical Approach for Compton-Rayleigh Scatter Peak Analysis for the Mars Science Laboratory Alpha Particle X-ray Spectrometer"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gellert, Ralf"],"dc:creator":["Tesselaar, Dustin"],"dc:date.accessioned":["2015-11-20T18:53:40Z"],"dc:date.available":["2016-09-25T05:00:16Z"],"dc:date.copyright":["2015-08"],"dc:date.created":["2015-09-25"],"dc:date.issued":["2015-11-20"],"dc:description.abstract":["As part of a suite of complimentary science instruments onboard the Mars Science Laboratory rover, the alpha particle X-ray spectrometer (APXS) determines the chemical abundances of Martian rocks and soils for elements from Na to Y via particle induced X-ray emission and X-ray fluorescence. Due to attenuation effects, elements with Z < 11 cannot be directly detected. These invisible components can be quantified indirectly by the Compton-Rayleigh scatter-peaks in APXS spectra. This thesis focuses on the development of an analytical simulation program (CRAM) used to predict the Compton-Rayleigh ratio (C/R) for APXS spectra in a more timely manner than the existing Monte Carlo method (MarsGeom). The simulated C/R, when related to the experimental C/R, is used to quantify any excess or deficit of invisible components in APXS targets. The results of CRAM are compared to MarsGeom and both datasets agree, giving a limit of invisible component detection of approximately 5 wt%."],"dc:identifier.uri":["http://hdl.handle.net/10214/9337"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["Compton Scattering","Rayleigh Scattering","Physics","APXS","Alpha Particle X-ray Spectrometer","XRF","PIXE"],"dc:title":["An Analytical Approach for Compton-Rayleigh Scatter Peak Analysis for the Mars Science Laboratory Alpha Particle X-ray Spectrometer"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:23:13Z"}