{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9354"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9354","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Canine Atlantoaxial Ventral Stabilization: Computed Tomography Analysis of Optimal Safe Implantation Corridors and Comparison of the Technical Outcome and Biomechanical Properties of 3 Surgical Techniques","abstract":"Canine atlantoaxial instability is a severely debilitating condition most commonly affecting Toy breed dogs that can result in sudden cardio-respiratory arrest. Surgical correction of atlantoaxial subluxation requires positioning of implants into the atlas and axis which is often perceived as a hazardous procedure and has been associated with unacceptably high perioperative mortality rates. This thesis investigates the most commonly reported ventral techniques of atlantoaxial stabilization attempting to improve currently available technical descriptions. The first part was aimed at developing a method of 3D analysis of vertebral bone corridors in order to generate precise definitions of optimal implant placement that could be used intraoperatively. We developed and validated a semi-automated method using free open-source version of OsiriXTM DICOM viewer and Microsoft® Excel software programs. This method was subsequently applied to a population of 27 dogs to generate objective definitions of atlantoaxial optimal safe implantation corridors. In the second part, we used these definitions to position implants in a population of 21 Beagle cadavers simulating intraoperative conditions of atlantoaxial stabilization. A 3D drill guide prototype was designed to allow positioning of the implants according to the previously generated definitions. Three commonly reported techniques of ventral atlantoaxial stabilization and 5 different implant sites were statistically compared. This study provided insights on technical limitations of the different methods of stabilization as well as biomechanical data that should be considered when performing these surgeries in clinical cases.","abstract_html":"Canine atlantoaxial instability is a severely debilitating condition most commonly affecting Toy breed dogs that can result in sudden cardio-respiratory arrest. Surgical correction of atlantoaxial subluxation requires positioning of implants into the atlas and axis which is often perceived as a hazardous procedure and has been associated with unacceptably high perioperative mortality rates. This thesis investigates the most commonly reported ventral techniques of atlantoaxial stabilization attempting to improve currently available technical descriptions. The first part was aimed at developing a method of 3D analysis of vertebral bone corridors in order to generate precise definitions of optimal implant placement that could be used intraoperatively. We developed and validated a semi-automated method using free open-source version of OsiriXTM DICOM viewer and Microsoft® Excel software programs. This method was subsequently applied to a population of 27 dogs to generate objective definitions of atlantoaxial optimal safe implantation corridors. In the second part, we used these definitions to position implants in a population of 21 Beagle cadavers simulating intraoperative conditions of atlantoaxial stabilization. A 3D drill guide prototype was designed to allow positioning of the implants according to the previously generated definitions. Three commonly reported techniques of ventral atlantoaxial stabilization and 5 different implant sites were statistically compared. This study provided insights on technical limitations of the different methods of stabilization as well as biomechanical data that should be considered when performing these surgeries in clinical cases.","abstract_has_math":false,"creators":["Leblond, Guillaume"],"institution":"University of Guelph","degree_name":"Doctor of Veterinary Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Clinical Studies","school":null,"contributors":[],"advisors":["Gaitero, Luis","Moens, Noel"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-12-02","date_published":"2015-12-02","updated_at":"2026-11-19T08:26:04Z","subjects":["dog","canine","atlas","axis","atlantoaxial instability","vertebral canal violation","atlantoaxial stabilization","atlantoaxial biomechanics"],"languages":["en"],"rights":["Attribution-NonCommercial 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9354","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9354","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F9354","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9354","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gaitero, Luis","Moens, Noel"]},{"key":"dc:creator","label":"Author","values":["Leblond, Guillaume"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-12-02T20:04:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-12-02T20:04:50Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015-11"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-11-11"]},{"key":"dc:date.issued","label":"Date","values":["2015-12-02"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Clinical Studies"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Veterinary Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Veterinary Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dog","canine","atlas","axis","atlantoaxial instability","vertebral canal violation","atlantoaxial stabilization","atlantoaxial biomechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9354"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Canine atlantoaxial instability is a severely debilitating condition most commonly affecting Toy breed dogs that can result in sudden cardio-respiratory arrest. Surgical correction of atlantoaxial subluxation requires positioning of implants into the atlas and axis which is often perceived as a hazardous procedure and has been associated with unacceptably high perioperative mortality rates. This thesis investigates the most commonly reported ventral techniques of atlantoaxial stabilization attempting to improve currently available technical descriptions. The first part was aimed at developing a method of 3D analysis of vertebral bone corridors in order to generate precise definitions of optimal implant placement that could be used intraoperatively. We developed and validated a semi-automated method using free open-source version of OsiriXTM DICOM viewer and Microsoft® Excel software programs. This method was subsequently applied to a population of 27 dogs to generate objective definitions of atlantoaxial optimal safe implantation corridors. In the second part, we used these definitions to position implants in a population of 21 Beagle cadavers simulating intraoperative conditions of atlantoaxial stabilization. A 3D drill guide prototype was designed to allow positioning of the implants according to the previously generated definitions. Three commonly reported techniques of ventral atlantoaxial stabilization and 5 different implant sites were statistically compared. This study provided insights on technical limitations of the different methods of stabilization as well as biomechanical data that should be considered when performing these surgeries in clinical cases."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Veterinary College Pet Trust"]},{"key":"dc:title","label":"Title","values":["Canine Atlantoaxial Ventral Stabilization: Computed Tomography Analysis of Optimal Safe Implantation Corridors and Comparison of the Technical Outcome and Biomechanical Properties of 3 Surgical Techniques"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gaitero, Luis","Moens, Noel"],"dc:creator":["Leblond, Guillaume"],"dc:date.accessioned":["2015-12-02T20:04:50Z"],"dc:date.available":["2015-12-02T20:04:50Z"],"dc:date.copyright":["2015-11"],"dc:date.created":["2015-11-11"],"dc:date.issued":["2015-12-02"],"dc:description.abstract":["Canine atlantoaxial instability is a severely debilitating condition most commonly affecting Toy breed dogs that can result in sudden cardio-respiratory arrest. Surgical correction of atlantoaxial subluxation requires positioning of implants into the atlas and axis which is often perceived as a hazardous procedure and has been associated with unacceptably high perioperative mortality rates. This thesis investigates the most commonly reported ventral techniques of atlantoaxial stabilization attempting to improve currently available technical descriptions. The first part was aimed at developing a method of 3D analysis of vertebral bone corridors in order to generate precise definitions of optimal implant placement that could be used intraoperatively. We developed and validated a semi-automated method using free open-source version of OsiriXTM DICOM viewer and Microsoft® Excel software programs. This method was subsequently applied to a population of 27 dogs to generate objective definitions of atlantoaxial optimal safe implantation corridors. In the second part, we used these definitions to position implants in a population of 21 Beagle cadavers simulating intraoperative conditions of atlantoaxial stabilization. A 3D drill guide prototype was designed to allow positioning of the implants according to the previously generated definitions. Three commonly reported techniques of ventral atlantoaxial stabilization and 5 different implant sites were statistically compared. This study provided insights on technical limitations of the different methods of stabilization as well as biomechanical data that should be considered when performing these surgeries in clinical cases."],"dc:description.sponsorship":["Ontario Veterinary College Pet Trust"],"dc:identifier.uri":["http://hdl.handle.net/10214/9354"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc/2.5/ca/"],"dc:subject":["dog","canine","atlas","axis","atlantoaxial instability","vertebral canal violation","atlantoaxial stabilization","atlantoaxial biomechanics"],"dc:title":["Canine Atlantoaxial Ventral Stabilization: Computed Tomography Analysis of Optimal Safe Implantation Corridors and Comparison of the Technical Outcome and Biomechanical Properties of 3 Surgical Techniques"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Clinical Studies"],"thesis:degree_name":["Doctor of Veterinary Science"],"thesis:degree_program":["Veterinary Science"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:04Z"}