{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9927"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9927","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"T wave and QT interval in the Standardbred horse: A descriptive study","abstract":"The human T wave and QT interval are well characterized. As long and short QT interval and QT interval dispersion are associated with arrhythmias and sudden death, influential factors, methods of measurement and heart rate (HR) correction are numerous. In horses, significance has been attached to QRS duration, T morphology, and QT interval, but clinical associations are not well supported and measurement not standardized. This study used holter monitoring of clinically normal Standardbred horses at rest and during exercise to develop an automated algorithm for measurement of T characteristics and QT interval. The algorithm was tested on 545 ECG segments of 12 successive RR intervals and successfully identified 97.0% of key waveform points. QT onset and offset were reliably identified 99.8% and 94.5% of the time respectively. While longitudinal studies will be required, this algorithm should aid in establishing normal equine QT intervals and accurate HR correction methods.","abstract_html":"The human T wave and QT interval are well characterized. As long and short QT interval and QT interval dispersion are associated with arrhythmias and sudden death, influential factors, methods of measurement and heart rate (HR) correction are numerous. In horses, significance has been attached to QRS duration, T morphology, and QT interval, but clinical associations are not well supported and measurement not standardized. This study used holter monitoring of clinically normal Standardbred horses at rest and during exercise to develop an automated algorithm for measurement of T characteristics and QT interval. The algorithm was tested on 545 ECG segments of 12 successive RR intervals and successfully identified 97.0% of key waveform points. QT onset and offset were reliably identified 99.8% and 94.5% of the time respectively. While longitudinal studies will be required, this algorithm should aid in establishing normal equine QT intervals and accurate HR correction methods.","abstract_has_math":false,"creators":["Preiss, Erin"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Biomedical Sciences","school":null,"contributors":[],"advisors":["Hanna, Brad","Physick-Sheard, Peter"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-09-06","date_published":"2016-09-06","updated_at":"2026-11-19T08:22:59Z","subjects":["Equine","QT interval","T wave","Algorithm"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9927","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9927","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F9927","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9927","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hanna, Brad","Physick-Sheard, Peter"]},{"key":"dc:creator","label":"Author","values":["Preiss, Erin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-09-06T18:54:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-06T18:54:31Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2016"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-08-12"]},{"key":"dc:date.issued","label":"Date","values":["2016-09-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Biomedical Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Equine","QT interval","T wave","Algorithm"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9927"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The human T wave and QT interval are well characterized. As long and short QT interval and QT interval dispersion are associated with arrhythmias and sudden death, influential factors, methods of measurement and heart rate (HR) correction are numerous. In horses, significance has been attached to QRS duration, T morphology, and QT interval, but clinical associations are not well supported and measurement not standardized. This study used holter monitoring of clinically normal Standardbred horses at rest and during exercise to develop an automated algorithm for measurement of T characteristics and QT interval. The algorithm was tested on 545 ECG segments of 12 successive RR intervals and successfully identified 97.0% of key waveform points. QT onset and offset were reliably identified 99.8% and 94.5% of the time respectively. While longitudinal studies will be required, this algorithm should aid in establishing normal equine QT intervals and accurate HR correction methods."]},{"key":"dc:title","label":"Title","values":["T wave and QT interval in the Standardbred horse: A descriptive study"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hanna, Brad","Physick-Sheard, Peter"],"dc:creator":["Preiss, Erin"],"dc:date.accessioned":["2016-09-06T18:54:31Z"],"dc:date.available":["2016-09-06T18:54:31Z"],"dc:date.copyright":["2016"],"dc:date.created":["2016-08-12"],"dc:date.issued":["2016-09-06"],"dc:description.abstract":["The human T wave and QT interval are well characterized. As long and short QT interval and QT interval dispersion are associated with arrhythmias and sudden death, influential factors, methods of measurement and heart rate (HR) correction are numerous. In horses, significance has been attached to QRS duration, T morphology, and QT interval, but clinical associations are not well supported and measurement not standardized. This study used holter monitoring of clinically normal Standardbred horses at rest and during exercise to develop an automated algorithm for measurement of T characteristics and QT interval. The algorithm was tested on 545 ECG segments of 12 successive RR intervals and successfully identified 97.0% of key waveform points. QT onset and offset were reliably identified 99.8% and 94.5% of the time respectively. While longitudinal studies will be required, this algorithm should aid in establishing normal equine QT intervals and accurate HR correction methods."],"dc:identifier.uri":["http://hdl.handle.net/10214/9927"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["Equine","QT interval","T wave","Algorithm"],"dc:title":["T wave and QT interval in the Standardbred horse: A descriptive study"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Biomedical Sciences"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Biomedical Sciences"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:59Z"}