{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/9991"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/9991","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Anesthetic and Cardio-Pulmonary Effects of Propofol or Alfaxalone With or Without Midazolam Co-induction in Fentanyl Sedated Dogs","abstract":"This thesis describes a prospective, randomized, incomplete Latin-square crossover, blind trial to investigate the effects of midazolam (M) as a co-induction agent in dogs induced and maintained with propofol (P) or alfaxalone (A) for diagnostic imaging. The quality of induction and recovery, induction and maintenance dose requirements for P or A, ease of maintenance using total intravenous anesthesia (TIVA), and cardio-pulmonary effects were determined in ten dogs assigned to P-S: P with saline (S); A-S: A with S; P-M: P with M; A-M: A with M. Fentanyl (7 µg kg-1, IV) was administered 10 minutes prior to an IV bolus of P (1 mg kg-1) or A (0.5 mg kg-1) followed by M (0.3 mg kg-1, IV) or S and additional boluses of P or A for intubation, followed by P or A TIVA during imaging. The induction quality was significantly better in A-M versus A-S, P-M versus P-S, and A-M versus P-S. The induction dose was significantly lower in P-M versus P-S, and A-M versus A-S. The TIVA rate with P-M was significantly lower than P-S but similar between A-M and A-S. Sedation, extubation and recovery quality, and TIVA duration were similar between treatments. Time to standing was significantly longer for A than P, but was similar within A or P treatments. After induction, heart rate (HR) was significantly higher in A-M than A-S and P-S. During imaging, HR of A-S and A-M were significantly higher than P-S. Before recovery, HR of A-M was significantly higher than P-S. Systolic blood pressure of A-S was significantly higher than A-M and P-M. There was no significant treatment difference for mean or diastolic blood pressure, cardiac index (CI), respiratory rate, occurrence of apnea, end-tidal CO2, and blood gas values. However, CI and HR significantly decreased after imaging compared to other phases. Midazolam improved the quality and reduced the required dose for both P and A induction, and reduced TIVA rate of P. There was no significant cardiopulmonary difference identified between treatments despite co-induction with M. The decrease in CI and HR after imaging warrants close monitoring during recovery.","abstract_html":"This thesis describes a prospective, randomized, incomplete Latin-square crossover, blind trial to investigate the effects of midazolam (M) as a co-induction agent in dogs induced and maintained with propofol (P) or alfaxalone (A) for diagnostic imaging. The quality of induction and recovery, induction and maintenance dose requirements for P or A, ease of maintenance using total intravenous anesthesia (TIVA), and cardio-pulmonary effects were determined in ten dogs assigned to P-S: P with saline (S); A-S: A with S; P-M: P with M; A-M: A with M. Fentanyl (7 µg kg-1, IV) was administered 10 minutes prior to an IV bolus of P (1 mg kg-1) or A (0.5 mg kg-1) followed by M (0.3 mg kg-1, IV) or S and additional boluses of P or A for intubation, followed by P or A TIVA during imaging. The induction quality was significantly better in A-M versus A-S, P-M versus P-S, and A-M versus P-S. The induction dose was significantly lower in P-M versus P-S, and A-M versus A-S. The TIVA rate with P-M was significantly lower than P-S but similar between A-M and A-S. Sedation, extubation and recovery quality, and TIVA duration were similar between treatments. Time to standing was significantly longer for A than P, but was similar within A or P treatments. After induction, heart rate (HR) was significantly higher in A-M than A-S and P-S. During imaging, HR of A-S and A-M were significantly higher than P-S. Before recovery, HR of A-M was significantly higher than P-S. Systolic blood pressure of A-S was significantly higher than A-M and P-M. There was no significant treatment difference for mean or diastolic blood pressure, cardiac index (CI), respiratory rate, occurrence of apnea, end-tidal CO2, and blood gas values. However, CI and HR significantly decreased after imaging compared to other phases. Midazolam improved the quality and reduced the required dose for both P and A induction, and reduced TIVA rate of P. There was no significant cardiopulmonary difference identified between treatments despite co-induction with M. The decrease in CI and HR after imaging warrants close monitoring during recovery.","abstract_has_math":false,"creators":["Liao, PenTing"],"institution":"University of Guelph","degree_name":"Doctor of Veterinary Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Clinical Studies","school":null,"contributors":[],"advisors":["Sinclair, Melissa"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-09-08","date_published":"2016-09-08","updated_at":"2026-11-19T08:25:00Z","subjects":["anesthesia","propofol","alfaxalone","midazolam","dog","TIVA","induction","coinduction"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/9991","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/9991","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F9991","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F9991","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sinclair, Melissa"]},{"key":"dc:creator","label":"Author","values":["Liao, PenTing"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-09-08T16:16:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-08T16:16:12Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2016-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-08-23"]},{"key":"dc:date.issued","label":"Date","values":["2016-09-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Clinical Studies"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Veterinary Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Clinical Studies"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["anesthesia","propofol","alfaxalone","midazolam","dog","TIVA","induction","coinduction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/9991"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes a prospective, randomized, incomplete Latin-square crossover, blind trial to investigate the effects of midazolam (M) as a co-induction agent in dogs induced and maintained with propofol (P) or alfaxalone (A) for diagnostic imaging. The quality of induction and recovery, induction and maintenance dose requirements for P or A, ease of maintenance using total intravenous anesthesia (TIVA), and cardio-pulmonary effects were determined in ten dogs assigned to P-S: P with saline (S); A-S: A with S; P-M: P with M; A-M: A with M. Fentanyl (7 µg kg-1, IV) was administered 10 minutes prior to an IV bolus of P (1 mg kg-1) or A (0.5 mg kg-1) followed by M (0.3 mg kg-1, IV) or S and additional boluses of P or A for intubation, followed by P or A TIVA during imaging. The induction quality was significantly better in A-M versus A-S, P-M versus P-S, and A-M versus P-S. The induction dose was significantly lower in P-M versus P-S, and A-M versus A-S. The TIVA rate with P-M was significantly lower than P-S but similar between A-M and A-S. Sedation, extubation and recovery quality, and TIVA duration were similar between treatments. Time to standing was significantly longer for A than P, but was similar within A or P treatments. After induction, heart rate (HR) was significantly higher in A-M than A-S and P-S. During imaging, HR of A-S and A-M were significantly higher than P-S. Before recovery, HR of A-M was significantly higher than P-S. Systolic blood pressure of A-S was significantly higher than A-M and P-M. There was no significant treatment difference for mean or diastolic blood pressure, cardiac index (CI), respiratory rate, occurrence of apnea, end-tidal CO2, and blood gas values. However, CI and HR significantly decreased after imaging compared to other phases. Midazolam improved the quality and reduced the required dose for both P and A induction, and reduced TIVA rate of P. There was no significant cardiopulmonary difference identified between treatments despite co-induction with M. The decrease in CI and HR after imaging warrants close monitoring during recovery."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Veterinary College Pet Trust"]},{"key":"dc:title","label":"Title","values":["Anesthetic and Cardio-Pulmonary Effects of Propofol or Alfaxalone With or Without Midazolam Co-induction in Fentanyl Sedated Dogs"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sinclair, Melissa"],"dc:creator":["Liao, PenTing"],"dc:date.accessioned":["2016-09-08T16:16:12Z"],"dc:date.available":["2016-09-08T16:16:12Z"],"dc:date.copyright":["2016-08"],"dc:date.created":["2016-08-23"],"dc:date.issued":["2016-09-08"],"dc:description.abstract":["This thesis describes a prospective, randomized, incomplete Latin-square crossover, blind trial to investigate the effects of midazolam (M) as a co-induction agent in dogs induced and maintained with propofol (P) or alfaxalone (A) for diagnostic imaging. The quality of induction and recovery, induction and maintenance dose requirements for P or A, ease of maintenance using total intravenous anesthesia (TIVA), and cardio-pulmonary effects were determined in ten dogs assigned to P-S: P with saline (S); A-S: A with S; P-M: P with M; A-M: A with M. Fentanyl (7 µg kg-1, IV) was administered 10 minutes prior to an IV bolus of P (1 mg kg-1) or A (0.5 mg kg-1) followed by M (0.3 mg kg-1, IV) or S and additional boluses of P or A for intubation, followed by P or A TIVA during imaging. The induction quality was significantly better in A-M versus A-S, P-M versus P-S, and A-M versus P-S. The induction dose was significantly lower in P-M versus P-S, and A-M versus A-S. The TIVA rate with P-M was significantly lower than P-S but similar between A-M and A-S. Sedation, extubation and recovery quality, and TIVA duration were similar between treatments. Time to standing was significantly longer for A than P, but was similar within A or P treatments. After induction, heart rate (HR) was significantly higher in A-M than A-S and P-S. During imaging, HR of A-S and A-M were significantly higher than P-S. Before recovery, HR of A-M was significantly higher than P-S. Systolic blood pressure of A-S was significantly higher than A-M and P-M. There was no significant treatment difference for mean or diastolic blood pressure, cardiac index (CI), respiratory rate, occurrence of apnea, end-tidal CO2, and blood gas values. However, CI and HR significantly decreased after imaging compared to other phases. Midazolam improved the quality and reduced the required dose for both P and A induction, and reduced TIVA rate of P. There was no significant cardiopulmonary difference identified between treatments despite co-induction with M. The decrease in CI and HR after imaging warrants close monitoring during recovery."],"dc:description.sponsorship":["Ontario Veterinary College Pet Trust"],"dc:identifier.uri":["http://hdl.handle.net/10214/9991"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["anesthesia","propofol","alfaxalone","midazolam","dog","TIVA","induction","coinduction"],"dc:title":["Anesthetic and Cardio-Pulmonary Effects of Propofol or Alfaxalone With or Without Midazolam Co-induction in Fentanyl Sedated Dogs"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Clinical Studies"],"thesis:degree_name":["Doctor of Veterinary Science"],"thesis:degree_program":["Clinical Studies"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:00Z"}