{"id":{"repo_id":"huddersfield","oai_identifier":"oai:eprints.hud.ac.uk:35005"},"canonical_url":"https://search.ndltd.org/etd/huddersfield/oai:eprints.hud.ac.uk:35005","repository":{"repo_id":"huddersfield","name":"University of Huddersfield","base_url":"http://eprints.hud.ac.uk/cgi/oai2"},"display":{"title":"Radiation Protection Studies for Radiobiology","abstract":"Hadron therapy is a new treatment technique for cancer. Clinical studies [1] have demonstrated that hadron therapy is clinically more effective than conventional radiotherapy as it delivers the dose to the tumour, sparing the healthy tissue. Although this method reduces the additional dose delivered to the healthy tissues, due to the beam delivery systems the patients and the personnel are exposed to a secondary dose. Therefore, one of the main tasks for medical physicists is to make sure that the treatments are delivered according to the treatment plan. This thesis is focused on the verification of the secondary dose received by the patient or the personnel during and after the irradiation sessions at three different facilities: the Clatterbridge Cancer Centre, the Christie Proton Therapy Centre and OpenMed at CERN. The ambient dose equivalent calculations were studied using the FLUKA Monte Carlo code. These calculations investigate whether the shielding methods meet the existing radiation protection requirements and if the dose delivered to the patients or staff is kept As Low As Reasonably Achievable (ALARA) [38].","abstract_html":"Hadron therapy is a new treatment technique for cancer. Clinical studies [1] have demonstrated that hadron therapy is clinically more effective than conventional radiotherapy as it delivers the dose to the tumour, sparing the healthy tissue. Although this method reduces the additional dose delivered to the healthy tissues, due to the beam delivery systems the patients and the personnel are exposed to a secondary dose. Therefore, one of the main tasks for medical physicists is to make sure that the treatments are delivered according to the treatment plan. This thesis is focused on the verification of the secondary dose received by the patient or the personnel during and after the irradiation sessions at three different facilities: the Clatterbridge Cancer Centre, the Christie Proton Therapy Centre and OpenMed at CERN. The ambient dose equivalent calculations were studied using the FLUKA Monte Carlo code. These calculations investigate whether the shielding methods meet the existing radiation protection requirements and if the dose delivered to the patients or staff is kept As Low As Reasonably Achievable (ALARA) [38].","abstract_has_math":false,"creators":[],"institution":"University of Huddersfield","degree_name":"phd","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Barlow, Roger","Kacperek, Andrzej","Taylor, Michael","Roy, Ghislain"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-06","date_published":"2018-06","updated_at":"2026-11-26T13:50:52Z","subjects":["RC Internal medicine","RC0254 Neoplasms. Tumors. Oncology (including Cancer)"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://eprints.hud.ac.uk/id/eprint/35005/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://eprints.hud.ac.uk/id/eprint/35005/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Ahuddersfield%3Aoai%3Aeprints.hud.ac.uk%3A35005","prefix":"oai_dc"},"source_record":{"url":"http://eprints.hud.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.hud.ac.uk%3A35005","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Barlow, Roger","Kacperek, Andrzej","Taylor, Michael","Roy, Ghislain"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-06"]},{"key":"dc:date.issued","label":"Date","values":["2018-06"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Computing and Engineering","International Institute for Accelerator Applications"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Huddersfield"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RC Internal medicine","RC0254 Neoplasms. Tumors. Oncology (including Cancer)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.hud.ac.uk/id/eprint/35005/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hadron therapy is a new treatment technique for cancer. Clinical studies [1] have demonstrated that hadron therapy is clinically more effective than conventional radiotherapy as it delivers the dose to the tumour, sparing the healthy tissue. Although this method reduces the additional dose delivered to the healthy tissues, due to the beam delivery systems the patients and the personnel are exposed to a secondary dose. Therefore, one of the main tasks for medical physicists is to make sure that the treatments are delivered according to the treatment plan. This thesis is focused on the verification of the secondary dose received by the patient or the personnel during and after the irradiation sessions at three different facilities: the Clatterbridge Cancer Centre, the Christie Proton Therapy Centre and OpenMed at CERN. The ambient dose equivalent calculations were studied using the FLUKA Monte Carlo code. These calculations investigate whether the shielding methods meet the existing radiation protection requirements and if the dose delivered to the patients or staff is kept As Low As Reasonably Achievable (ALARA) [38]."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Radiation Protection Studies for Radiobiology"]}]}],"canonical_facts":{"dc:contributor.advisor":["Barlow, Roger","Kacperek, Andrzej","Taylor, Michael","Roy, Ghislain"],"dc:date":["2018-06"],"dc:date.issued":["2018-06"],"dc:description.abstract":["Hadron therapy is a new treatment technique for cancer. Clinical studies [1] have demonstrated that hadron therapy is clinically more effective than conventional radiotherapy as it delivers the dose to the tumour, sparing the healthy tissue. Although this method reduces the additional dose delivered to the healthy tissues, due to the beam delivery systems the patients and the personnel are exposed to a secondary dose. Therefore, one of the main tasks for medical physicists is to make sure that the treatments are delivered according to the treatment plan. This thesis is focused on the verification of the secondary dose received by the patient or the personnel during and after the irradiation sessions at three different facilities: the Clatterbridge Cancer Centre, the Christie Proton Therapy Centre and OpenMed at CERN. The ambient dose equivalent calculations were studied using the FLUKA Monte Carlo code. These calculations investigate whether the shielding methods meet the existing radiation protection requirements and if the dose delivered to the patients or staff is kept As Low As Reasonably Achievable (ALARA) [38]."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://eprints.hud.ac.uk/id/eprint/35005/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Computing and Engineering","International Institute for Accelerator Applications"],"dc:publisher.institution":["University of Huddersfield"],"dc:subject":["RC Internal medicine","RC0254 Neoplasms. Tumors. Oncology (including Cancer)"],"dcterms:accessrights":["public"],"dc:title":["Radiation Protection Studies for Radiobiology"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["phd"]},"updated_at":"2026-11-26T13:50:52Z"}