{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/28855"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/28855","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Seismic performance of accelerated bridge construction (ABC) precast bulb-tee girder-to-bent cap connection","abstract":"<p>With the total number of structurally deficient or functionally obsolete bridges at more than 20% of the nation’s 607,380 bridges in 2013, the nation need to work effectively to decrease the total number below to 15% over the next decade. Accelerated Bridge Construction (ABC) techniques using the precast components are beneficial to effectively repair and replace the deficient bridges by reducing the period of onsite construction and improving the construction quality. However, the knowledge gap regarding the seismic performance of connections between the precast components limits the extensive implementation of ABC techniques in the moderate-to-high seismic regions of the country. Current Caltrans Seismic Design Criteria stipulates to degrade the connection between the precast girder and bent cap to a pinned connection under sever seismic event, which results in an inefficient bridge design. To overcome this issue, two innovative details for the precast bulb-tee girder to cast-in-place bent cap connection have been experimentally tested at Iowa State University. These two moment resisting connection details, named as the Extend Strand with a Mechanical Splice (ESMS) connection and the Extended Strand with a Lap Splice (ESLS) connection, consist of deck reinforcement, unstressed strands extended from the precast girder, and dowel bars grouted through the web of the girder as shown in following schematic. The deck reinforcement placed over the connection region provides the negative moment resistance. The strands spliced by mechanical splice chucks and lap splices within the ESMS and ESLS connection respectively develop the tension continuity to resist the positive moment, and the dowel bars are also designed to withstand the applied positive moments. Both connection details exhibited the adequate capacity to develop the moment resisting connection between the girders and the bent cap under target seismic demands. The testing results of this study reveal that the concrete crushing at the bottom of girder-to-cap interface induced the strength softening of the connection under the negative moments beyond the target value. For the connection behavior in the positive moment direction, the shear friction behavior was developed at the interface between the precast girder and the cast-in-place diaphragm poured around the girder, which provided the positive moment resistance. Meanwhile, the tension force generated by the strands extended from the girder contribute to the positive moment resistance as well. Based on the understanding of the behavior of the ESMS and ESLS connections exhibited within the experimental tests, an accurate but straightforward design methodology was then established to develop a guide to help with field implementation for these innovative connection details. The success in evaluating the seismic performance of the ESMS and ESLS connections confirms that both connections are adequate to develop the moment resisting connection for the precast bulb-tee girders subjected to the vertical and lateral loads and can be used within the routine bridge designs.</p>","abstract_html":"&lt;p&gt;With the total number of structurally deficient or functionally obsolete bridges at more than 20% of the nation’s 607,380 bridges in 2013, the nation need to work effectively to decrease the total number below to 15% over the next decade. Accelerated Bridge Construction (ABC) techniques using the precast components are beneficial to effectively repair and replace the deficient bridges by reducing the period of onsite construction and improving the construction quality. However, the knowledge gap regarding the seismic performance of connections between the precast components limits the extensive implementation of ABC techniques in the moderate-to-high seismic regions of the country. Current Caltrans Seismic Design Criteria stipulates to degrade the connection between the precast girder and bent cap to a pinned connection under sever seismic event, which results in an inefficient bridge design. To overcome this issue, two innovative details for the precast bulb-tee girder to cast-in-place bent cap connection have been experimentally tested at Iowa State University. These two moment resisting connection details, named as the Extend Strand with a Mechanical Splice (ESMS) connection and the Extended Strand with a Lap Splice (ESLS) connection, consist of deck reinforcement, unstressed strands extended from the precast girder, and dowel bars grouted through the web of the girder as shown in following schematic. The deck reinforcement placed over the connection region provides the negative moment resistance. The strands spliced by mechanical splice chucks and lap splices within the ESMS and ESLS connection respectively develop the tension continuity to resist the positive moment, and the dowel bars are also designed to withstand the applied positive moments. Both connection details exhibited the adequate capacity to develop the moment resisting connection between the girders and the bent cap under target seismic demands. The testing results of this study reveal that the concrete crushing at the bottom of girder-to-cap interface induced the strength softening of the connection under the negative moments beyond the target value. For the connection behavior in the positive moment direction, the shear friction behavior was developed at the interface between the precast girder and the cast-in-place diaphragm poured around the girder, which provided the positive moment resistance. Meanwhile, the tension force generated by the strands extended from the girder contribute to the positive moment resistance as well. Based on the understanding of the behavior of the ESMS and ESLS connections exhibited within the experimental tests, an accurate but straightforward design methodology was then established to develop a guide to help with field implementation for these innovative connection details. The success in evaluating the seismic performance of the ESMS and ESLS connections confirms that both connections are adequate to develop the moment resisting connection for the precast bulb-tee girders subjected to the vertical and lateral loads and can be used within the routine bridge designs.&lt;/p&gt;","abstract_has_math":false,"creators":["Cheng, Zhao"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":null,"degree_department":"Department of Civil, Construction and Environmental Engineering","school":null,"contributors":[],"advisors":["Sri Sritharan"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-01-01","date_published":"2015-01-01","updated_at":"2026-11-19T04:34:46Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/28855"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/28855","href":"https://dr.lib.iastate.edu/handle/20.500.12876/28855","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/etd/14670/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/etd/14670/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["5677","8052034"],"render_values":[{"text":"5677","href":null,"code":true},{"text":"8052034","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/etd/14670/Cheng_iastate_0097M_15206.pdf|||Fri Jan 14 20:24:19 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/etd/14670/Cheng_iastate_0097M_15206.pdf|||Fri Jan 14 20:24:19 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/etd-180810-4222","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/etd-180810-4222","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"embargoed","embargo_until":"2001-01-01","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F28855","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F28855","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sri Sritharan"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Civil, Construction and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Cheng, Zhao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-08-11T14:37:12.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-06-30T02:58:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-06-30T02:58:20Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Thu Jan 01 00:00:00 UTC 2015"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2001-01-01"]},{"key":"dc:date.issued","label":"Date","values":["2015-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["933e9c94-323c-4da9-9e8e-861692825f91"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Civil Engineering","Structural Engineering"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Civil Engineering (Structural Engineering)","Civil Engineering","Structural Engineering","Accelerate Bridge Construction","Girder-to-cap Connection","Seismic Design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/etd/14670/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/etd-180810-4222"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["5677","8052034"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/28855"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/etd/14670/Cheng_iastate_0097M_15206.pdf|||Fri Jan 14 20:24:19 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>With the total number of structurally deficient or functionally obsolete bridges at more than 20% of the nation’s 607,380 bridges in 2013, the nation need to work effectively to decrease the total number below to 15% over the next decade. Accelerated Bridge Construction (ABC) techniques using the precast components are beneficial to effectively repair and replace the deficient bridges by reducing the period of onsite construction and improving the construction quality. However, the knowledge gap regarding the seismic performance of connections between the precast components limits the extensive implementation of ABC techniques in the moderate-to-high seismic regions of the country. Current Caltrans Seismic Design Criteria stipulates to degrade the connection between the precast girder and bent cap to a pinned connection under sever seismic event, which results in an inefficient bridge design. To overcome this issue, two innovative details for the precast bulb-tee girder to cast-in-place bent cap connection have been experimentally tested at Iowa State University. These two moment resisting connection details, named as the Extend Strand with a Mechanical Splice (ESMS) connection and the Extended Strand with a Lap Splice (ESLS) connection, consist of deck reinforcement, unstressed strands extended from the precast girder, and dowel bars grouted through the web of the girder as shown in following schematic. The deck reinforcement placed over the connection region provides the negative moment resistance. The strands spliced by mechanical splice chucks and lap splices within the ESMS and ESLS connection respectively develop the tension continuity to resist the positive moment, and the dowel bars are also designed to withstand the applied positive moments. Both connection details exhibited the adequate capacity to develop the moment resisting connection between the girders and the bent cap under target seismic demands. The testing results of this study reveal that the concrete crushing at the bottom of girder-to-cap interface induced the strength softening of the connection under the negative moments beyond the target value. For the connection behavior in the positive moment direction, the shear friction behavior was developed at the interface between the precast girder and the cast-in-place diaphragm poured around the girder, which provided the positive moment resistance. Meanwhile, the tension force generated by the strands extended from the girder contribute to the positive moment resistance as well. Based on the understanding of the behavior of the ESMS and ESLS connections exhibited within the experimental tests, an accurate but straightforward design methodology was then established to develop a guide to help with field implementation for these innovative connection details. The success in evaluating the seismic performance of the ESMS and ESLS connections confirms that both connections are adequate to develop the moment resisting connection for the precast bulb-tee girders subjected to the vertical and lateral loads and can be used within the routine bridge designs.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Seismic performance of accelerated bridge construction (ABC) precast bulb-tee girder-to-bent cap connection"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","etd/14670"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sri Sritharan"],"dc:contributor.department":["Department of Civil, Construction and Environmental Engineering"],"dc:creator":["Cheng, Zhao"],"dc:date":["2018-08-11T14:37:12.000"],"dc:date.accessioned":["2020-06-30T02:58:20Z"],"dc:date.available":["2020-06-30T02:58:20Z"],"dc:date.copyright":["Thu Jan 01 00:00:00 UTC 2015"],"dc:date.embargo":["2001-01-01"],"dc:date.issued":["2015-01-01"],"dc:description.abstract":["<p>With the total number of structurally deficient or functionally obsolete bridges at more than 20% of the nation’s 607,380 bridges in 2013, the nation need to work effectively to decrease the total number below to 15% over the next decade. Accelerated Bridge Construction (ABC) techniques using the precast components are beneficial to effectively repair and replace the deficient bridges by reducing the period of onsite construction and improving the construction quality. However, the knowledge gap regarding the seismic performance of connections between the precast components limits the extensive implementation of ABC techniques in the moderate-to-high seismic regions of the country. Current Caltrans Seismic Design Criteria stipulates to degrade the connection between the precast girder and bent cap to a pinned connection under sever seismic event, which results in an inefficient bridge design. To overcome this issue, two innovative details for the precast bulb-tee girder to cast-in-place bent cap connection have been experimentally tested at Iowa State University. These two moment resisting connection details, named as the Extend Strand with a Mechanical Splice (ESMS) connection and the Extended Strand with a Lap Splice (ESLS) connection, consist of deck reinforcement, unstressed strands extended from the precast girder, and dowel bars grouted through the web of the girder as shown in following schematic. The deck reinforcement placed over the connection region provides the negative moment resistance. The strands spliced by mechanical splice chucks and lap splices within the ESMS and ESLS connection respectively develop the tension continuity to resist the positive moment, and the dowel bars are also designed to withstand the applied positive moments. Both connection details exhibited the adequate capacity to develop the moment resisting connection between the girders and the bent cap under target seismic demands. The testing results of this study reveal that the concrete crushing at the bottom of girder-to-cap interface induced the strength softening of the connection under the negative moments beyond the target value. For the connection behavior in the positive moment direction, the shear friction behavior was developed at the interface between the precast girder and the cast-in-place diaphragm poured around the girder, which provided the positive moment resistance. Meanwhile, the tension force generated by the strands extended from the girder contribute to the positive moment resistance as well. Based on the understanding of the behavior of the ESMS and ESLS connections exhibited within the experimental tests, an accurate but straightforward design methodology was then established to develop a guide to help with field implementation for these innovative connection details. The success in evaluating the seismic performance of the ESMS and ESLS connections confirms that both connections are adequate to develop the moment resisting connection for the precast bulb-tee girders subjected to the vertical and lateral loads and can be used within the routine bridge designs.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/etd/14670/"],"dc:identifier.doi":["https://doi.org/10.31274/etd-180810-4222"],"dc:identifier.other":["5677","8052034"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/28855"],"dc:language.iso":["en"],"dc:relation.orgunit":["933e9c94-323c-4da9-9e8e-861692825f91"],"dc:subject.discipline":["Civil Engineering","Structural Engineering"],"dc:subject.keyword":["Civil Engineering (Structural Engineering)","Civil Engineering","Structural Engineering","Accelerate Bridge Construction","Girder-to-cap Connection","Seismic Design"],"dc:title":["Seismic performance of accelerated bridge construction (ABC) precast bulb-tee girder-to-bent cap connection"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","etd/14670"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/etd/14670/Cheng_iastate_0097M_15206.pdf|||Fri Jan 14 20:24:19 UTC 2022"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T04:34:46Z"}