{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/31455"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/31455","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Deep learning for design and optimization of bioprosthetic heart valves","abstract":"<p>In the traditional industry model, even the slightest design change has to go through the entire optimization process. Once the parametric geometry is created, an analysis is run, depending on the various inputs, boundary conditions and the desired output values. These outputs are studied and optimized against the input values using either traditional data analytics or by analysis of testing results. Based on the results of this analysis, the design parameters and inputs are changed as desired and the optimization cycle is repeated. Such industries need methods to reduce this time by a significant amount. The motivation of this study is to create an algorithm that learns the structural analysis of a bioprosthetic heart valve using a convolutional neural network, which on being trained can predict the results of the analysis given any new geometry without going through the process of simulation, which is time consuming and may not be feasible without appropriate resources at all times. This is achieved by exploiting the parametric non-uniform roational B-splines (NURBS) formulation of the heart valve geometry through isogeometric analysis. The initial and final deformations of about 18000 simulations are provided as training data to a deep convolutional neural network. Key parameters of interest such as coaptation area are predicted and all results are validated against the results obtained from traditional structural analysis.</p>","abstract_html":"&lt;p&gt;In the traditional industry model, even the slightest design change has to go through the entire optimization process. Once the parametric geometry is created, an analysis is run, depending on the various inputs, boundary conditions and the desired output values. These outputs are studied and optimized against the input values using either traditional data analytics or by analysis of testing results. Based on the results of this analysis, the design parameters and inputs are changed as desired and the optimization cycle is repeated. Such industries need methods to reduce this time by a significant amount. The motivation of this study is to create an algorithm that learns the structural analysis of a bioprosthetic heart valve using a convolutional neural network, which on being trained can predict the results of the analysis given any new geometry without going through the process of simulation, which is time consuming and may not be feasible without appropriate resources at all times. This is achieved by exploiting the parametric non-uniform roational B-splines (NURBS) formulation of the heart valve geometry through isogeometric analysis. The initial and final deformations of about 18000 simulations are provided as training data to a deep convolutional neural network. Key parameters of interest such as coaptation area are predicted and all results are validated against the results obtained from traditional structural analysis.&lt;/p&gt;","abstract_has_math":false,"creators":["Nallagonda, Sahiti"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":"Mechanical Engineering","degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Ming-Chen Hsu"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-01-01","date_published":"2018-01-01","updated_at":"2026-11-19T04:36:20Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/etd/17272/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/etd/17272/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["8279","15016445"],"render_values":[{"text":"8279","href":null,"code":true},{"text":"15016445","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/etd/17272/Nallagonda_iastate_0097M_17699.pdf|||Fri Jan 14 21:19:33 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/etd/17272/Nallagonda_iastate_0097M_17699.pdf|||Fri Jan 14 21:19:33 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://dr.lib.iastate.edu/handle/20.500.12876/31455","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dr.lib.iastate.edu/handle/20.500.12876/31455","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2019-05-16","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F31455","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F31455","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ming-Chen Hsu"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Nallagonda, Sahiti"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-09-21T00:13:30.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-06-30T03:17:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-06-30T03:17:12Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Sat Dec 01 00:00:00 UTC 2018"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2019-05-16"]},{"key":"dc:date.issued","label":"Date","values":["2018-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Mechanical Engineering"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Biomedical devices","Deep learning","Isogeometric analysis","Machine learning","Neural networks","Simulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/etd/17272/"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["8279","15016445"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/31455"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/etd/17272/Nallagonda_iastate_0097M_17699.pdf|||Fri Jan 14 21:19:33 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>In the traditional industry model, even the slightest design change has to go through the entire optimization process. Once the parametric geometry is created, an analysis is run, depending on the various inputs, boundary conditions and the desired output values. These outputs are studied and optimized against the input values using either traditional data analytics or by analysis of testing results. Based on the results of this analysis, the design parameters and inputs are changed as desired and the optimization cycle is repeated. Such industries need methods to reduce this time by a significant amount. The motivation of this study is to create an algorithm that learns the structural analysis of a bioprosthetic heart valve using a convolutional neural network, which on being trained can predict the results of the analysis given any new geometry without going through the process of simulation, which is time consuming and may not be feasible without appropriate resources at all times. This is achieved by exploiting the parametric non-uniform roational B-splines (NURBS) formulation of the heart valve geometry through isogeometric analysis. The initial and final deformations of about 18000 simulations are provided as training data to a deep convolutional neural network. Key parameters of interest such as coaptation area are predicted and all results are validated against the results obtained from traditional structural analysis.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Deep learning for design and optimization of bioprosthetic heart valves"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","etd/17272"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ming-Chen Hsu"],"dc:contributor.department":["Department of Mechanical Engineering"],"dc:creator":["Nallagonda, Sahiti"],"dc:date":["2019-09-21T00:13:30.000"],"dc:date.accessioned":["2020-06-30T03:17:12Z"],"dc:date.available":["2020-06-30T03:17:12Z"],"dc:date.copyright":["Sat Dec 01 00:00:00 UTC 2018"],"dc:date.embargo":["2019-05-16"],"dc:date.issued":["2018-01-01"],"dc:description.abstract":["<p>In the traditional industry model, even the slightest design change has to go through the entire optimization process. Once the parametric geometry is created, an analysis is run, depending on the various inputs, boundary conditions and the desired output values. These outputs are studied and optimized against the input values using either traditional data analytics or by analysis of testing results. Based on the results of this analysis, the design parameters and inputs are changed as desired and the optimization cycle is repeated. Such industries need methods to reduce this time by a significant amount. The motivation of this study is to create an algorithm that learns the structural analysis of a bioprosthetic heart valve using a convolutional neural network, which on being trained can predict the results of the analysis given any new geometry without going through the process of simulation, which is time consuming and may not be feasible without appropriate resources at all times. This is achieved by exploiting the parametric non-uniform roational B-splines (NURBS) formulation of the heart valve geometry through isogeometric analysis. The initial and final deformations of about 18000 simulations are provided as training data to a deep convolutional neural network. Key parameters of interest such as coaptation area are predicted and all results are validated against the results obtained from traditional structural analysis.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/etd/17272/"],"dc:identifier.other":["8279","15016445"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/31455"],"dc:language.iso":["en"],"dc:relation.orgunit":["6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59"],"dc:subject.discipline":["Mechanical Engineering"],"dc:subject.keyword":["Biomedical devices","Deep learning","Isogeometric analysis","Machine learning","Neural networks","Simulation"],"dc:title":["Deep learning for design and optimization of bioprosthetic heart valves"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","etd/17272"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/etd/17272/Nallagonda_iastate_0097M_17699.pdf|||Fri Jan 14 21:19:33 UTC 2022"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T04:36:20Z"}