{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/65055"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/65055","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Calcium phosphate ceramic composites used for orthopedic implant applications","abstract":"<p>The objective of the first of two research projects was to make a new composite material that would have both bone bonding capabilities and appropriate mechanical properties for use in orthopedic applications. Implant-bone responses were compared using transcortical implants designed from osteoceramic fired in air, osteoceramic fired in hydrogen, 316L stainless steel mixed with aggregates of osteoceramic, 316L stainless steel, and ultra high molecular weight polyethylene mixed with aggregates of osteoceramic. The osteoceramic material, developed at Iowa State University, was a biologically active composite consisting of tricalcium phosphate and magnesium aluminate spinel;Ten of each of these implants were placed transcortically in the femurs of adult New Zealand white rabbits and evaluated using mechanical push-out testing, microradiography, and image analysis after 18 weeks of implantation. The interface shear strength values were found to be higher for the steel and steel/osteoceramic than for the osteoceramic (air and H fired) and polyethylene/osteoceramic. This difference in strength was not statistically significant for the osteoceramic fired in air, but the difference was significant for the osteoceramic fired in hydrogen and for the polyethylene/osteoceramic. The direct bony attachment values were also found to be higher for the steel and steel/osteoceramic than the osteoceramics. These values were not statistically different. The osteoceramic materials were found to have high open porosity values due to the manufacturing process, and contamination with coolant may have occurred during the grinding process. This may have caused the atypically low shear strength and attachment values for the osteoceramics;The objective of the second research project was to make a new bone-bridging device to guide bone to repair and remodel across a defect that would otherwise not be repaired. This device, called a guide tube, could replace the need for bone grafting materials and the problems associated with their implantation because bone would be able to heal and support itself. The unique tubular design of the guide tube, developed at Iowa State University, was made from the osteoceramic material;Six of these implants were placed into the femurs of canines which had had surgical ostectomies that exceeded the bridging limit of bone. Three other canines, used for controls, had similarly sized defects and did not receive implants. The clinical performance of the implants was evaluated using macroradiographs to assess bone healing and remodeling across the defects;Bone bridging and mineralization were observed in four of the six femurs receiving guide tubes. The two non-healing bones were possibly over-stabilized by the internal fixation; therefore, some screws were removed from the bone plate to destabilize it in hopes of stimulating bone repair. Eventually, these femurs showed some bone repair along the guide tube. The three controls showed minimal bridging or mineralization of the defect.</p>","abstract_html":"&lt;p&gt;The objective of the first of two research projects was to make a new composite material that would have both bone bonding capabilities and appropriate mechanical properties for use in orthopedic applications. Implant-bone responses were compared using transcortical implants designed from osteoceramic fired in air, osteoceramic fired in hydrogen, 316L stainless steel mixed with aggregates of osteoceramic, 316L stainless steel, and ultra high molecular weight polyethylene mixed with aggregates of osteoceramic. The osteoceramic material, developed at Iowa State University, was a biologically active composite consisting of tricalcium phosphate and magnesium aluminate spinel;Ten of each of these implants were placed transcortically in the femurs of adult New Zealand white rabbits and evaluated using mechanical push-out testing, microradiography, and image analysis after 18 weeks of implantation. The interface shear strength values were found to be higher for the steel and steel/osteoceramic than for the osteoceramic (air and H fired) and polyethylene/osteoceramic. This difference in strength was not statistically significant for the osteoceramic fired in air, but the difference was significant for the osteoceramic fired in hydrogen and for the polyethylene/osteoceramic. The direct bony attachment values were also found to be higher for the steel and steel/osteoceramic than the osteoceramics. These values were not statistically different. The osteoceramic materials were found to have high open porosity values due to the manufacturing process, and contamination with coolant may have occurred during the grinding process. This may have caused the atypically low shear strength and attachment values for the osteoceramics;The objective of the second research project was to make a new bone-bridging device to guide bone to repair and remodel across a defect that would otherwise not be repaired. This device, called a guide tube, could replace the need for bone grafting materials and the problems associated with their implantation because bone would be able to heal and support itself. The unique tubular design of the guide tube, developed at Iowa State University, was made from the osteoceramic material;Six of these implants were placed into the femurs of canines which had had surgical ostectomies that exceeded the bridging limit of bone. Three other canines, used for controls, had similarly sized defects and did not receive implants. The clinical performance of the implants was evaluated using macroradiographs to assess bone healing and remodeling across the defects;Bone bridging and mineralization were observed in four of the six femurs receiving guide tubes. The two non-healing bones were possibly over-stabilized by the internal fixation; therefore, some screws were removed from the bone plate to destabilize it in hopes of stimulating bone repair. Eventually, these femurs showed some bone repair along the guide tube. The three controls showed minimal bridging or mineralization of the defect.&lt;/p&gt;","abstract_has_math":false,"creators":["Olson, Curtis"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":"dissertation","degree_discipline":null,"degree_department":"Department of Chemical and Biological Engineering","school":null,"contributors":[],"advisors":["Thomas D. McGee"],"committee_chairs":[],"committee_members":[],"year":1996,"date_issued":"1996","date_published":"1996","updated_at":"2026-11-19T04:37:54Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/65055"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/65055","href":"https://dr.lib.iastate.edu/handle/20.500.12876/65055","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/11762/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/11762/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["12761","6510235"],"render_values":[{"text":"12761","href":null,"code":true},{"text":"6510235","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/11762/r_9725475.pdf|||Fri Jan 14 18:57:38 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/11762/r_9725475.pdf|||Fri Jan 14 18:57:38 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/rtd-180813-10692","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/rtd-180813-10692","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F65055","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F65055","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Thomas D. McGee"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Chemical and Biological Engineering"]},{"key":"dc:creator","label":"Author","values":["Olson, Curtis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-08-23T09:53:48.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-06-30T07:15:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-06-30T07:15:32Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Mon Jan 01 00:00:00 UTC 1996"]},{"key":"dc:date.issued","label":"Date","values":["1996"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["86545861-382c-4c15-8c52-eb8e9afe6b75"]},{"key":"dc:type","label":"Dc Type","values":["dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Biomedical Engineering and Bioengineering","Materials Science and Engineering","Veterinary Medicine"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/11762/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/rtd-180813-10692"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["12761","6510235"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/65055"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/11762/r_9725475.pdf|||Fri Jan 14 18:57:38 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The objective of the first of two research projects was to make a new composite material that would have both bone bonding capabilities and appropriate mechanical properties for use in orthopedic applications. Implant-bone responses were compared using transcortical implants designed from osteoceramic fired in air, osteoceramic fired in hydrogen, 316L stainless steel mixed with aggregates of osteoceramic, 316L stainless steel, and ultra high molecular weight polyethylene mixed with aggregates of osteoceramic. The osteoceramic material, developed at Iowa State University, was a biologically active composite consisting of tricalcium phosphate and magnesium aluminate spinel;Ten of each of these implants were placed transcortically in the femurs of adult New Zealand white rabbits and evaluated using mechanical push-out testing, microradiography, and image analysis after 18 weeks of implantation. The interface shear strength values were found to be higher for the steel and steel/osteoceramic than for the osteoceramic (air and H fired) and polyethylene/osteoceramic. This difference in strength was not statistically significant for the osteoceramic fired in air, but the difference was significant for the osteoceramic fired in hydrogen and for the polyethylene/osteoceramic. The direct bony attachment values were also found to be higher for the steel and steel/osteoceramic than the osteoceramics. These values were not statistically different. The osteoceramic materials were found to have high open porosity values due to the manufacturing process, and contamination with coolant may have occurred during the grinding process. This may have caused the atypically low shear strength and attachment values for the osteoceramics;The objective of the second research project was to make a new bone-bridging device to guide bone to repair and remodel across a defect that would otherwise not be repaired. This device, called a guide tube, could replace the need for bone grafting materials and the problems associated with their implantation because bone would be able to heal and support itself. The unique tubular design of the guide tube, developed at Iowa State University, was made from the osteoceramic material;Six of these implants were placed into the femurs of canines which had had surgical ostectomies that exceeded the bridging limit of bone. Three other canines, used for controls, had similarly sized defects and did not receive implants. The clinical performance of the implants was evaluated using macroradiographs to assess bone healing and remodeling across the defects;Bone bridging and mineralization were observed in four of the six femurs receiving guide tubes. The two non-healing bones were possibly over-stabilized by the internal fixation; therefore, some screws were removed from the bone plate to destabilize it in hopes of stimulating bone repair. Eventually, these femurs showed some bone repair along the guide tube. The three controls showed minimal bridging or mineralization of the defect.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Calcium phosphate ceramic composites used for orthopedic implant applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","rtd/11762"]}]}],"canonical_facts":{"dc:contributor.advisor":["Thomas D. McGee"],"dc:contributor.department":["Department of Chemical and Biological Engineering"],"dc:creator":["Olson, Curtis"],"dc:date":["2018-08-23T09:53:48.000"],"dc:date.accessioned":["2020-06-30T07:15:32Z"],"dc:date.available":["2020-06-30T07:15:32Z"],"dc:date.copyright":["Mon Jan 01 00:00:00 UTC 1996"],"dc:date.issued":["1996"],"dc:description.abstract":["<p>The objective of the first of two research projects was to make a new composite material that would have both bone bonding capabilities and appropriate mechanical properties for use in orthopedic applications. Implant-bone responses were compared using transcortical implants designed from osteoceramic fired in air, osteoceramic fired in hydrogen, 316L stainless steel mixed with aggregates of osteoceramic, 316L stainless steel, and ultra high molecular weight polyethylene mixed with aggregates of osteoceramic. The osteoceramic material, developed at Iowa State University, was a biologically active composite consisting of tricalcium phosphate and magnesium aluminate spinel;Ten of each of these implants were placed transcortically in the femurs of adult New Zealand white rabbits and evaluated using mechanical push-out testing, microradiography, and image analysis after 18 weeks of implantation. The interface shear strength values were found to be higher for the steel and steel/osteoceramic than for the osteoceramic (air and H fired) and polyethylene/osteoceramic. This difference in strength was not statistically significant for the osteoceramic fired in air, but the difference was significant for the osteoceramic fired in hydrogen and for the polyethylene/osteoceramic. The direct bony attachment values were also found to be higher for the steel and steel/osteoceramic than the osteoceramics. These values were not statistically different. The osteoceramic materials were found to have high open porosity values due to the manufacturing process, and contamination with coolant may have occurred during the grinding process. This may have caused the atypically low shear strength and attachment values for the osteoceramics;The objective of the second research project was to make a new bone-bridging device to guide bone to repair and remodel across a defect that would otherwise not be repaired. This device, called a guide tube, could replace the need for bone grafting materials and the problems associated with their implantation because bone would be able to heal and support itself. The unique tubular design of the guide tube, developed at Iowa State University, was made from the osteoceramic material;Six of these implants were placed into the femurs of canines which had had surgical ostectomies that exceeded the bridging limit of bone. Three other canines, used for controls, had similarly sized defects and did not receive implants. The clinical performance of the implants was evaluated using macroradiographs to assess bone healing and remodeling across the defects;Bone bridging and mineralization were observed in four of the six femurs receiving guide tubes. The two non-healing bones were possibly over-stabilized by the internal fixation; therefore, some screws were removed from the bone plate to destabilize it in hopes of stimulating bone repair. Eventually, these femurs showed some bone repair along the guide tube. The three controls showed minimal bridging or mineralization of the defect.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/rtd/11762/"],"dc:identifier.doi":["https://doi.org/10.31274/rtd-180813-10692"],"dc:identifier.other":["12761","6510235"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/65055"],"dc:language.iso":["en"],"dc:relation.orgunit":["86545861-382c-4c15-8c52-eb8e9afe6b75"],"dc:subject.discipline":["Biomedical Engineering and Bioengineering","Materials Science and Engineering","Veterinary Medicine"],"dc:subject.keyword":["Biomedical engineering"],"dc:title":["Calcium phosphate ceramic composites used for orthopedic implant applications"],"dc:type":["dissertation"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","rtd/11762"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/rtd/11762/r_9725475.pdf|||Fri Jan 14 18:57:38 UTC 2022"],"thesis:degree_level":["dissertation"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-11-19T04:37:54Z"}