{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/71055"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/71055","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Performance of strip seals in Iowa bridges: pilot study","abstract":"<p>A pilot study was conducted on the premature failures of neoprene strip seals in expansion joints in Iowa bridges. In a relatively large number of bridges, strip seals have pulled out of the steel extrusions or otherwise failed well before the expected life span of the seal. The most serious consequence of a strip seal failure is damage to the bridge substructure due to salt, water, and debris interacting with the substructure.</p> <p>A literature review was performed. Manufacturers' specifications and recommendations, practices in the states bordering Iowa, and Iowa DOT design and installation guidelines were reviewed. Iowa DOT bridge databases were analyzed. A national survey was conducted on the use and performance of strip seals.</p> <p>With guidance from the Iowa DOT, twelve in-service bridges with strip seal expansion joints were selected for detailed investigation. Effective bridge temperatures and corresponding expansion joint openings were measured, DOT inspection reports were reviewed, and likely cause(s) of premature failures of strip seals were proposed.</p> <p>Experimental results show that for a majority of these serious failures (all in concrete girder bridges), the joint opening at 0°F predicted by the Iowa DOT design equations, the joint opening at 0°F extrapolated from the experimental data, or both, are larger than the movement rating of the strip seal specified on the bridge plans. Other likely causes of premature failures of seals in the twelve bridges include debris and ice in the seal cavity, skew of bridge deck, improper installation, and improper setting of the initial gap.</p>","abstract_html":"&lt;p&gt;A pilot study was conducted on the premature failures of neoprene strip seals in expansion joints in Iowa bridges. In a relatively large number of bridges, strip seals have pulled out of the steel extrusions or otherwise failed well before the expected life span of the seal. The most serious consequence of a strip seal failure is damage to the bridge substructure due to salt, water, and debris interacting with the substructure.&lt;/p&gt; &lt;p&gt;A literature review was performed. Manufacturers&#x27; specifications and recommendations, practices in the states bordering Iowa, and Iowa DOT design and installation guidelines were reviewed. Iowa DOT bridge databases were analyzed. A national survey was conducted on the use and performance of strip seals.&lt;/p&gt; &lt;p&gt;With guidance from the Iowa DOT, twelve in-service bridges with strip seal expansion joints were selected for detailed investigation. Effective bridge temperatures and corresponding expansion joint openings were measured, DOT inspection reports were reviewed, and likely cause(s) of premature failures of strip seals were proposed.&lt;/p&gt; &lt;p&gt;Experimental results show that for a majority of these serious failures (all in concrete girder bridges), the joint opening at 0°F predicted by the Iowa DOT design equations, the joint opening at 0°F extrapolated from the experimental data, or both, are larger than the movement rating of the strip seal specified on the bridge plans. Other likely causes of premature failures of seals in the twelve bridges include debris and ice in the seal cavity, skew of bridge deck, improper installation, and improper setting of the initial gap.&lt;/p&gt;","abstract_has_math":false,"creators":["Kau, Vui-Bin"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":null,"degree_department":"Department of Civil, Construction and Environmental Engineering","school":null,"contributors":[],"advisors":["Lowell F. Greimann","James E. Bolluyt"],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001-01-01","date_published":"2001-01-01","updated_at":"2026-11-19T04:40:16Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/71055"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/71055","href":"https://dr.lib.iastate.edu/handle/20.500.12876/71055","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/17261/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/17261/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["18260","8321872"],"render_values":[{"text":"18260","href":null,"code":true},{"text":"8321872","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/17261/kau.pdf|||Fri Jan 14 21:19:25 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/17261/kau.pdf|||Fri Jan 14 21:19:25 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/rtd-180813-8005","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/rtd-180813-8005","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F71055","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F71055","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lowell F. Greimann","James E. Bolluyt"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Civil, Construction and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Kau, Vui-Bin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-08-22T16:46:43.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-06-30T07:58:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-06-30T07:58:37Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Mon Jan 01 00:00:00 UTC 2001"]},{"key":"dc:date.issued","label":"Date","values":["2001-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["933e9c94-323c-4da9-9e8e-861692825f91"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Civil Engineering","Structural Engineering"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Civil engineering","Structural engineering","Civil and construction engineering","Civil Construction and Environmental Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/17261/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/rtd-180813-8005"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["18260","8321872"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/71055"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/17261/kau.pdf|||Fri Jan 14 21:19:25 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A pilot study was conducted on the premature failures of neoprene strip seals in expansion joints in Iowa bridges. In a relatively large number of bridges, strip seals have pulled out of the steel extrusions or otherwise failed well before the expected life span of the seal. The most serious consequence of a strip seal failure is damage to the bridge substructure due to salt, water, and debris interacting with the substructure.</p> <p>A literature review was performed. Manufacturers' specifications and recommendations, practices in the states bordering Iowa, and Iowa DOT design and installation guidelines were reviewed. Iowa DOT bridge databases were analyzed. A national survey was conducted on the use and performance of strip seals.</p> <p>With guidance from the Iowa DOT, twelve in-service bridges with strip seal expansion joints were selected for detailed investigation. Effective bridge temperatures and corresponding expansion joint openings were measured, DOT inspection reports were reviewed, and likely cause(s) of premature failures of strip seals were proposed.</p> <p>Experimental results show that for a majority of these serious failures (all in concrete girder bridges), the joint opening at 0°F predicted by the Iowa DOT design equations, the joint opening at 0°F extrapolated from the experimental data, or both, are larger than the movement rating of the strip seal specified on the bridge plans. Other likely causes of premature failures of seals in the twelve bridges include debris and ice in the seal cavity, skew of bridge deck, improper installation, and improper setting of the initial gap.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Performance of strip seals in Iowa bridges: pilot study"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","rtd/17261"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lowell F. Greimann","James E. Bolluyt"],"dc:contributor.department":["Department of Civil, Construction and Environmental Engineering"],"dc:creator":["Kau, Vui-Bin"],"dc:date":["2018-08-22T16:46:43.000"],"dc:date.accessioned":["2020-06-30T07:58:37Z"],"dc:date.available":["2020-06-30T07:58:37Z"],"dc:date.copyright":["Mon Jan 01 00:00:00 UTC 2001"],"dc:date.issued":["2001-01-01"],"dc:description.abstract":["<p>A pilot study was conducted on the premature failures of neoprene strip seals in expansion joints in Iowa bridges. In a relatively large number of bridges, strip seals have pulled out of the steel extrusions or otherwise failed well before the expected life span of the seal. The most serious consequence of a strip seal failure is damage to the bridge substructure due to salt, water, and debris interacting with the substructure.</p> <p>A literature review was performed. Manufacturers' specifications and recommendations, practices in the states bordering Iowa, and Iowa DOT design and installation guidelines were reviewed. Iowa DOT bridge databases were analyzed. A national survey was conducted on the use and performance of strip seals.</p> <p>With guidance from the Iowa DOT, twelve in-service bridges with strip seal expansion joints were selected for detailed investigation. Effective bridge temperatures and corresponding expansion joint openings were measured, DOT inspection reports were reviewed, and likely cause(s) of premature failures of strip seals were proposed.</p> <p>Experimental results show that for a majority of these serious failures (all in concrete girder bridges), the joint opening at 0°F predicted by the Iowa DOT design equations, the joint opening at 0°F extrapolated from the experimental data, or both, are larger than the movement rating of the strip seal specified on the bridge plans. Other likely causes of premature failures of seals in the twelve bridges include debris and ice in the seal cavity, skew of bridge deck, improper installation, and improper setting of the initial gap.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/rtd/17261/"],"dc:identifier.doi":["https://doi.org/10.31274/rtd-180813-8005"],"dc:identifier.other":["18260","8321872"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/71055"],"dc:language.iso":["en"],"dc:relation.orgunit":["933e9c94-323c-4da9-9e8e-861692825f91"],"dc:subject.discipline":["Civil Engineering","Structural Engineering"],"dc:subject.keyword":["Civil engineering","Structural engineering","Civil and construction engineering","Civil Construction and Environmental Engineering"],"dc:title":["Performance of strip seals in Iowa bridges: pilot study"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","rtd/17261"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/rtd/17261/kau.pdf|||Fri Jan 14 21:19:25 UTC 2022"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T04:40:16Z"}