{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/97152"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/97152","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Computer-aided design of an ergonomic computer mouse","abstract":"<p>The primary purpose of this thesis is to explain a device which could be used as an alternative for a computer mouse. Instead of using a regular roller found in an ordinary mouse, the device uses a pressure sensitive sensor to control the computer cursor on the monitor. The device is developed mainly for a personal computer with Universal Serial Bus (USB) capability. The computer should have an operating system of Microsoft Windows 98 or newer. The device does not need any additional driver, and it has a USB hot-plug-and-play feature. It uses a Human Interface Device (HID) driver provided by Windows. The device mainly has two buttons (right and left) and is approximately 4\" by 3\" by 2\" in size. Users can press their fingers on to the device to control the cursor. The device will be small enough to be fit inside a person's palm. The area has four pressure sensors used to move the cursor to the left, right, upward and downward. The user can control some parameters, such as cursor movement rate, by just controlling the amount of force pressed on that area. The device will be made from a soft material with a hard box inside. All the necessary components will be placed inside the box. Only the sensors are outside the box, so that the user can control the sensors by squeezing the device. This would make it comfortable for users to operate the device.</p>","abstract_html":"&lt;p&gt;The primary purpose of this thesis is to explain a device which could be used as an alternative for a computer mouse. Instead of using a regular roller found in an ordinary mouse, the device uses a pressure sensitive sensor to control the computer cursor on the monitor. The device is developed mainly for a personal computer with Universal Serial Bus (USB) capability. The computer should have an operating system of Microsoft Windows 98 or newer. The device does not need any additional driver, and it has a USB hot-plug-and-play feature. It uses a Human Interface Device (HID) driver provided by Windows. The device mainly has two buttons (right and left) and is approximately 4&quot; by 3&quot; by 2&quot; in size. Users can press their fingers on to the device to control the cursor. The device will be small enough to be fit inside a person&#x27;s palm. The area has four pressure sensors used to move the cursor to the left, right, upward and downward. The user can control some parameters, such as cursor movement rate, by just controlling the amount of force pressed on that area. The device will be made from a soft material with a hard box inside. All the necessary components will be placed inside the box. Only the sensors are outside the box, so that the user can control the sensors by squeezing the device. This would make it comfortable for users to operate the device.&lt;/p&gt;","abstract_has_math":false,"creators":["Arifin, Mohd"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":"Mechanical Engineering","degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002-01-01","date_published":"2002-01-01","updated_at":"2026-11-19T04:44:10Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97152"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/97152","href":"https://dr.lib.iastate.edu/handle/20.500.12876/97152","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/19785/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/19785/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["20784","18779708"],"render_values":[{"text":"20784","href":null,"code":true},{"text":"18779708","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/19785/Arifin_ISU_2002_A75.pdf|||Fri Jan 14 21:59:49 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/19785/Arifin_ISU_2002_A75.pdf|||Fri Jan 14 21:59:49 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/rtd-20200803-7","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/rtd-20200803-7","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F97152","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F97152","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Arifin, Mohd"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-08-05T05:00:45.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-02-26T08:37:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-26T08:37:54Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Tue Jan 01 00:00:00 UTC 2002"]},{"key":"dc:date.issued","label":"Date","values":["2002-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/19785/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/rtd-20200803-7"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["20784","18779708"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97152"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/19785/Arifin_ISU_2002_A75.pdf|||Fri Jan 14 21:59:49 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The primary purpose of this thesis is to explain a device which could be used as an alternative for a computer mouse. Instead of using a regular roller found in an ordinary mouse, the device uses a pressure sensitive sensor to control the computer cursor on the monitor. The device is developed mainly for a personal computer with Universal Serial Bus (USB) capability. The computer should have an operating system of Microsoft Windows 98 or newer. The device does not need any additional driver, and it has a USB hot-plug-and-play feature. It uses a Human Interface Device (HID) driver provided by Windows. The device mainly has two buttons (right and left) and is approximately 4\" by 3\" by 2\" in size. Users can press their fingers on to the device to control the cursor. The device will be small enough to be fit inside a person's palm. The area has four pressure sensors used to move the cursor to the left, right, upward and downward. The user can control some parameters, such as cursor movement rate, by just controlling the amount of force pressed on that area. The device will be made from a soft material with a hard box inside. All the necessary components will be placed inside the box. Only the sensors are outside the box, so that the user can control the sensors by squeezing the device. This would make it comfortable for users to operate the device.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Computer-aided design of an ergonomic computer mouse"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","rtd/19785"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Mechanical Engineering"],"dc:creator":["Arifin, Mohd"],"dc:date":["2020-08-05T05:00:45.000"],"dc:date.accessioned":["2021-02-26T08:37:54Z"],"dc:date.available":["2021-02-26T08:37:54Z"],"dc:date.copyright":["Tue Jan 01 00:00:00 UTC 2002"],"dc:date.issued":["2002-01-01"],"dc:description.abstract":["<p>The primary purpose of this thesis is to explain a device which could be used as an alternative for a computer mouse. Instead of using a regular roller found in an ordinary mouse, the device uses a pressure sensitive sensor to control the computer cursor on the monitor. The device is developed mainly for a personal computer with Universal Serial Bus (USB) capability. The computer should have an operating system of Microsoft Windows 98 or newer. The device does not need any additional driver, and it has a USB hot-plug-and-play feature. It uses a Human Interface Device (HID) driver provided by Windows. The device mainly has two buttons (right and left) and is approximately 4\" by 3\" by 2\" in size. Users can press their fingers on to the device to control the cursor. The device will be small enough to be fit inside a person's palm. The area has four pressure sensors used to move the cursor to the left, right, upward and downward. The user can control some parameters, such as cursor movement rate, by just controlling the amount of force pressed on that area. The device will be made from a soft material with a hard box inside. All the necessary components will be placed inside the box. Only the sensors are outside the box, so that the user can control the sensors by squeezing the device. This would make it comfortable for users to operate the device.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/rtd/19785/"],"dc:identifier.doi":["https://doi.org/10.31274/rtd-20200803-7"],"dc:identifier.other":["20784","18779708"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/97152"],"dc:language.iso":["en"],"dc:relation.orgunit":["6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59"],"dc:subject.keyword":["Mechanical engineering"],"dc:title":["Computer-aided design of an ergonomic computer mouse"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","rtd/19785"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/rtd/19785/Arifin_ISU_2002_A75.pdf|||Fri Jan 14 21:59:49 UTC 2022"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T04:44:10Z"}