{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/97409"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/97409","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Comparison of corrosivity of polymeric sulfate ferric and ferric chloride as coagulants in water treatment","abstract":"<p>This dissertation discusses the corrosion behavior of two coagulants used in water treatment, ferric chloride (FC) and polymeric ferric sulfate (PFS). Corrosion tests were performed to compare the corrosivity of these two coagulants on aluminum 6061 and steel 4140 specimens. Results showed that both temperature and concentration of the coagulants substantially impacted the corrosion rates. The corrosion rates increased with the increase of temperature and concentration. The results from a scanning electron microscope (SEM) showed that chloride anion caused more serious pitting than sulfate anion on both aluminum and steel specimens. Although SEM confirmed the existence of pitting corrosion, the results of weight loss indicated that the uniform corrosion predominate the corrosion mechanism, and pitting corrosion played a less important role. The test proved that PFS was less corrosive than FC, which may lead to the large-scale application of PFS in water and wastewater treatment in the near future.</p>","abstract_html":"&lt;p&gt;This dissertation discusses the corrosion behavior of two coagulants used in water treatment, ferric chloride (FC) and polymeric ferric sulfate (PFS). Corrosion tests were performed to compare the corrosivity of these two coagulants on aluminum 6061 and steel 4140 specimens. Results showed that both temperature and concentration of the coagulants substantially impacted the corrosion rates. The corrosion rates increased with the increase of temperature and concentration. The results from a scanning electron microscope (SEM) showed that chloride anion caused more serious pitting than sulfate anion on both aluminum and steel specimens. Although SEM confirmed the existence of pitting corrosion, the results of weight loss indicated that the uniform corrosion predominate the corrosion mechanism, and pitting corrosion played a less important role. The test proved that PFS was less corrosive than FC, which may lead to the large-scale application of PFS in water and wastewater treatment in the near future.&lt;/p&gt;","abstract_has_math":false,"creators":["Shi, Yonghui"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":"Civil Engineering (Environmental Engineering)","degree_department":"Department of Civil, Construction and Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-01-01","date_published":"2003-01-01","updated_at":"2026-11-19T04:44:10Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97409"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/97409","href":"https://dr.lib.iastate.edu/handle/20.500.12876/97409","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/20042/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/20042/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["21041","18791820"],"render_values":[{"text":"21041","href":null,"code":true},{"text":"18791820","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/20042/Shi_ISU_2003_S55.pdf|||Fri Jan 14 22:19:16 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/20042/Shi_ISU_2003_S55.pdf|||Fri Jan 14 22:19:16 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/rtd-20200803-365","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/rtd-20200803-365","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F97409","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F97409","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Civil, Construction and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Shi, Yonghui"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-08-05T05:04:30.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-02-26T08:44:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-26T08:44:20Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Wed Jan 01 00:00:00 UTC 2003"]},{"key":"dc:date.issued","label":"Date","values":["2003-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["933e9c94-323c-4da9-9e8e-861692825f91"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering (Environmental Engineering)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Civil and construction engineering","Civil engineering (Environmental engineering)","Environmental engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/20042/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/rtd-20200803-365"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["21041","18791820"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97409"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/20042/Shi_ISU_2003_S55.pdf|||Fri Jan 14 22:19:16 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>This dissertation discusses the corrosion behavior of two coagulants used in water treatment, ferric chloride (FC) and polymeric ferric sulfate (PFS). Corrosion tests were performed to compare the corrosivity of these two coagulants on aluminum 6061 and steel 4140 specimens. Results showed that both temperature and concentration of the coagulants substantially impacted the corrosion rates. The corrosion rates increased with the increase of temperature and concentration. The results from a scanning electron microscope (SEM) showed that chloride anion caused more serious pitting than sulfate anion on both aluminum and steel specimens. Although SEM confirmed the existence of pitting corrosion, the results of weight loss indicated that the uniform corrosion predominate the corrosion mechanism, and pitting corrosion played a less important role. The test proved that PFS was less corrosive than FC, which may lead to the large-scale application of PFS in water and wastewater treatment in the near future.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Comparison of corrosivity of polymeric sulfate ferric and ferric chloride as coagulants in water treatment"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","rtd/20042"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Civil, Construction and Environmental Engineering"],"dc:creator":["Shi, Yonghui"],"dc:date":["2020-08-05T05:04:30.000"],"dc:date.accessioned":["2021-02-26T08:44:20Z"],"dc:date.available":["2021-02-26T08:44:20Z"],"dc:date.copyright":["Wed Jan 01 00:00:00 UTC 2003"],"dc:date.issued":["2003-01-01"],"dc:description.abstract":["<p>This dissertation discusses the corrosion behavior of two coagulants used in water treatment, ferric chloride (FC) and polymeric ferric sulfate (PFS). Corrosion tests were performed to compare the corrosivity of these two coagulants on aluminum 6061 and steel 4140 specimens. Results showed that both temperature and concentration of the coagulants substantially impacted the corrosion rates. The corrosion rates increased with the increase of temperature and concentration. The results from a scanning electron microscope (SEM) showed that chloride anion caused more serious pitting than sulfate anion on both aluminum and steel specimens. Although SEM confirmed the existence of pitting corrosion, the results of weight loss indicated that the uniform corrosion predominate the corrosion mechanism, and pitting corrosion played a less important role. The test proved that PFS was less corrosive than FC, which may lead to the large-scale application of PFS in water and wastewater treatment in the near future.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/rtd/20042/"],"dc:identifier.doi":["https://doi.org/10.31274/rtd-20200803-365"],"dc:identifier.other":["21041","18791820"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/97409"],"dc:language.iso":["en"],"dc:relation.orgunit":["933e9c94-323c-4da9-9e8e-861692825f91"],"dc:subject.keyword":["Civil and construction engineering","Civil engineering (Environmental engineering)","Environmental engineering"],"dc:title":["Comparison of corrosivity of polymeric sulfate ferric and ferric chloride as coagulants in water treatment"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","rtd/20042"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/rtd/20042/Shi_ISU_2003_S55.pdf|||Fri Jan 14 22:19:16 UTC 2022"],"thesis:degree_discipline":["Civil Engineering (Environmental Engineering)"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T04:44:10Z"}