{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/97501"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/97501","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Energy savings in a commercial building with daylighting controls: empirical study and DOE-2 validation","abstract":"<p>Energy Resource Station in Ankeny, Iowa was used to conduct experiments comparing daylighting controls to a conventional lighting system. Side-by-side pairs of test rooms on the east, west, and south sides of the building were equipped with venetian blinds and tests were conducted in August, April, May, and June 2000 - 2001. Results showed savings in lighting energy up to 50% over a conventional system. Reheat and chiller energy usage were also examined. It was found that total energy (reheat, chiller, and lighting energy combined) was saved using daylighting for 24 of the 32 test days when all energy sources were combined. Maximum total energy savings was 29% for two days in June. The experimental results were used to validate a DOE-2.1E computer simulation. The simulation was able to predict total energy savings to within 11% of the experimental results. In most cases, DOE-2 overestimated energy usage.</p>","abstract_html":"&lt;p&gt;Energy Resource Station in Ankeny, Iowa was used to conduct experiments comparing daylighting controls to a conventional lighting system. Side-by-side pairs of test rooms on the east, west, and south sides of the building were equipped with venetian blinds and tests were conducted in August, April, May, and June 2000 - 2001. Results showed savings in lighting energy up to 50% over a conventional system. Reheat and chiller energy usage were also examined. It was found that total energy (reheat, chiller, and lighting energy combined) was saved using daylighting for 24 of the 32 test days when all energy sources were combined. Maximum total energy savings was 29% for two days in June. The experimental results were used to validate a DOE-2.1E computer simulation. The simulation was able to predict total energy savings to within 11% of the experimental results. In most cases, DOE-2 overestimated energy usage.&lt;/p&gt;","abstract_has_math":false,"creators":["Kuiken, Tamara"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":"Mechanical Engineering","degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002-01-01","date_published":"2002-01-01","updated_at":"2026-11-19T00:06:06Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97501"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/97501","href":"https://dr.lib.iastate.edu/handle/20.500.12876/97501","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/20134/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/20134/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["21133","18792595"],"render_values":[{"text":"21133","href":null,"code":true},{"text":"18792595","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/20134/Kuiken_ISU_2002_K85.pdf|||Fri Jan 14 22:20:11 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/20134/Kuiken_ISU_2002_K85.pdf|||Fri Jan 14 22:20:11 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/rtd-20200803-250","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/rtd-20200803-250","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F97501","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F97501","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Kuiken, Tamara"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-08-05T05:05:50.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-02-26T08:46:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-26T08:46:36Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Tue Jan 01 00:00:00 UTC 2002"]},{"key":"dc:date.issued","label":"Date","values":["2002-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/20134/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/rtd-20200803-250"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["21133","18792595"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97501"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/20134/Kuiken_ISU_2002_K85.pdf|||Fri Jan 14 22:20:11 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Energy Resource Station in Ankeny, Iowa was used to conduct experiments comparing daylighting controls to a conventional lighting system. Side-by-side pairs of test rooms on the east, west, and south sides of the building were equipped with venetian blinds and tests were conducted in August, April, May, and June 2000 - 2001. Results showed savings in lighting energy up to 50% over a conventional system. Reheat and chiller energy usage were also examined. It was found that total energy (reheat, chiller, and lighting energy combined) was saved using daylighting for 24 of the 32 test days when all energy sources were combined. Maximum total energy savings was 29% for two days in June. The experimental results were used to validate a DOE-2.1E computer simulation. The simulation was able to predict total energy savings to within 11% of the experimental results. In most cases, DOE-2 overestimated energy usage.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Energy savings in a commercial building with daylighting controls: empirical study and DOE-2 validation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","rtd/20134"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Mechanical Engineering"],"dc:creator":["Kuiken, Tamara"],"dc:date":["2020-08-05T05:05:50.000"],"dc:date.accessioned":["2021-02-26T08:46:36Z"],"dc:date.available":["2021-02-26T08:46:36Z"],"dc:date.copyright":["Tue Jan 01 00:00:00 UTC 2002"],"dc:date.issued":["2002-01-01"],"dc:description.abstract":["<p>Energy Resource Station in Ankeny, Iowa was used to conduct experiments comparing daylighting controls to a conventional lighting system. Side-by-side pairs of test rooms on the east, west, and south sides of the building were equipped with venetian blinds and tests were conducted in August, April, May, and June 2000 - 2001. Results showed savings in lighting energy up to 50% over a conventional system. Reheat and chiller energy usage were also examined. It was found that total energy (reheat, chiller, and lighting energy combined) was saved using daylighting for 24 of the 32 test days when all energy sources were combined. Maximum total energy savings was 29% for two days in June. The experimental results were used to validate a DOE-2.1E computer simulation. The simulation was able to predict total energy savings to within 11% of the experimental results. In most cases, DOE-2 overestimated energy usage.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/rtd/20134/"],"dc:identifier.doi":["https://doi.org/10.31274/rtd-20200803-250"],"dc:identifier.other":["21133","18792595"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/97501"],"dc:language.iso":["en"],"dc:relation.orgunit":["6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59"],"dc:subject.keyword":["Mechanical engineering"],"dc:title":["Energy savings in a commercial building with daylighting controls: empirical study and DOE-2 validation"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","rtd/20134"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/rtd/20134/Kuiken_ISU_2002_K85.pdf|||Fri Jan 14 22:20:11 UTC 2022"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T00:06:06Z"}