{"id":{"repo_id":"iastate","oai_identifier":"oai:dr.lib.iastate.edu:20.500.12876/97598"},"canonical_url":"https://search.ndltd.org/etd/iastate/oai:dr.lib.iastate.edu:20.500.12876/97598","repository":{"repo_id":"iastate","name":"Iowa State University","base_url":"https://dr.lib.iastate.edu/server/oai/request"},"display":{"title":"Evaluation of leachate treatment and recycle options using the Static Granular Bed Reactor","abstract":"<p>Three landfill leachate management strategies were evaluated by comparing simulated landfill columns while studying the application of the Static Granular Bed Reactor (SGBR) to leachate treatment. The three simulated landfill columns were operated in three different strategies. In column 1 (C1), the leachate was treated in the SGBR reactor and recycled to the top of C1. Column 2 (C2) recirculated the leachate without any treatment. Column 3 (C3) was a simulated conventional landfill without recirculation. With time, the COD concentration of leachate in each column decreased. C1 had its greatest reduction of COD in leachate due to removal in the SGBR and the landfill column itself. Moreover, gas production was accelerated by leachate recirculation owing to enhancement of waste degradation in landfill columns (C1 and C2). The SGBR pre-operating study showed fast acclimation (5 days) to substrate change and short start-up period (10 days) as evidenced by COD removal efficiencies ranging between 84% and 95% for leachate and non-fat dry milk. Incorporated in a leachate management strategy, the SGBR system was sustained in stability as evidenced by the stable pH and low VFA concentrations. Despite the low organic removal efficiency, the SGBR reactor treating leachate prior to recirculation in the simulated landfill column was effective at reducing the organic matter in leachate within the system. The feasibility of leachate treatment by the SGBR was demonstrated in this study.</p>","abstract_html":"&lt;p&gt;Three landfill leachate management strategies were evaluated by comparing simulated landfill columns while studying the application of the Static Granular Bed Reactor (SGBR) to leachate treatment. The three simulated landfill columns were operated in three different strategies. In column 1 (C1), the leachate was treated in the SGBR reactor and recycled to the top of C1. Column 2 (C2) recirculated the leachate without any treatment. Column 3 (C3) was a simulated conventional landfill without recirculation. With time, the COD concentration of leachate in each column decreased. C1 had its greatest reduction of COD in leachate due to removal in the SGBR and the landfill column itself. Moreover, gas production was accelerated by leachate recirculation owing to enhancement of waste degradation in landfill columns (C1 and C2). The SGBR pre-operating study showed fast acclimation (5 days) to substrate change and short start-up period (10 days) as evidenced by COD removal efficiencies ranging between 84% and 95% for leachate and non-fat dry milk. Incorporated in a leachate management strategy, the SGBR system was sustained in stability as evidenced by the stable pH and low VFA concentrations. Despite the low organic removal efficiency, the SGBR reactor treating leachate prior to recirculation in the simulated landfill column was effective at reducing the organic matter in leachate within the system. The feasibility of leachate treatment by the SGBR was demonstrated in this study.&lt;/p&gt;","abstract_has_math":false,"creators":["Park, Jaeyoung"],"institution":null,"degree_name":"Master of Science","degree_level":"thesis","degree_discipline":"Civil Engineering (Environmental Engineering)","degree_department":"Department of Civil, Construction and Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-01-01","date_published":"2004-01-01","updated_at":"2026-11-19T04:44:32Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97598"],"render_values":[{"text":"https://dr.lib.iastate.edu/handle/20.500.12876/97598","href":"https://dr.lib.iastate.edu/handle/20.500.12876/97598","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/20231/"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/20231/","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["21230","18970506"],"render_values":[{"text":"21230","href":null,"code":true},{"text":"18970506","href":null,"code":true}]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/20231/Park_ISU_2004_P37.pdf|||Fri Jan 14 22:21:50 UTC 2022"],"render_values":[{"text":"archive/lib.dr.iastate.edu/rtd/20231/Park_ISU_2004_P37.pdf|||Fri Jan 14 22:21:50 UTC 2022","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31274/rtd-20200817-24","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.31274/rtd-20200817-24","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aiastate%3Aoai%3Adr.lib.iastate.edu%3A20.500.12876%2F97598","prefix":"oai_dc"},"source_record":{"url":"https://dr.lib.iastate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.lib.iastate.edu%3A20.500.12876%2F97598","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Civil, Construction and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Park, Jaeyoung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-08-21T23:09:02.000"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-02-26T08:48:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-26T08:48:59Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["Thu Jan 01 00:00:00 UTC 2004"]},{"key":"dc:date.issued","label":"Date","values":["2004-01-01"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["933e9c94-323c-4da9-9e8e-861692825f91"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering (Environmental Engineering)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Civil, construction, and environmental engineering","Civil engineering (Environmental engineering)","Environmental engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["archive/lib.dr.iastate.edu/rtd/20231/"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.31274/rtd-20200817-24"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["21230","18970506"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dr.lib.iastate.edu/handle/20.500.12876/97598"]},{"key":"mods:identifier.filename","label":"Mods Identifier Filename","values":["archive/lib.dr.iastate.edu/rtd/20231/Park_ISU_2004_P37.pdf|||Fri Jan 14 22:21:50 UTC 2022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Three landfill leachate management strategies were evaluated by comparing simulated landfill columns while studying the application of the Static Granular Bed Reactor (SGBR) to leachate treatment. The three simulated landfill columns were operated in three different strategies. In column 1 (C1), the leachate was treated in the SGBR reactor and recycled to the top of C1. Column 2 (C2) recirculated the leachate without any treatment. Column 3 (C3) was a simulated conventional landfill without recirculation. With time, the COD concentration of leachate in each column decreased. C1 had its greatest reduction of COD in leachate due to removal in the SGBR and the landfill column itself. Moreover, gas production was accelerated by leachate recirculation owing to enhancement of waste degradation in landfill columns (C1 and C2). The SGBR pre-operating study showed fast acclimation (5 days) to substrate change and short start-up period (10 days) as evidenced by COD removal efficiencies ranging between 84% and 95% for leachate and non-fat dry milk. Incorporated in a leachate management strategy, the SGBR system was sustained in stability as evidenced by the stable pH and low VFA concentrations. Despite the low organic removal efficiency, the SGBR reactor treating leachate prior to recirculation in the simulated landfill column was effective at reducing the organic matter in leachate within the system. The feasibility of leachate treatment by the SGBR was demonstrated in this study.</p>"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of leachate treatment and recycle options using the Static Granular Bed Reactor"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:admin","label":"Local Admin","values":["isulib-bepress-aws-west","rtd/20231"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Civil, Construction and Environmental Engineering"],"dc:creator":["Park, Jaeyoung"],"dc:date":["2020-08-21T23:09:02.000"],"dc:date.accessioned":["2021-02-26T08:48:59Z"],"dc:date.available":["2021-02-26T08:48:59Z"],"dc:date.copyright":["Thu Jan 01 00:00:00 UTC 2004"],"dc:date.issued":["2004-01-01"],"dc:description.abstract":["<p>Three landfill leachate management strategies were evaluated by comparing simulated landfill columns while studying the application of the Static Granular Bed Reactor (SGBR) to leachate treatment. The three simulated landfill columns were operated in three different strategies. In column 1 (C1), the leachate was treated in the SGBR reactor and recycled to the top of C1. Column 2 (C2) recirculated the leachate without any treatment. Column 3 (C3) was a simulated conventional landfill without recirculation. With time, the COD concentration of leachate in each column decreased. C1 had its greatest reduction of COD in leachate due to removal in the SGBR and the landfill column itself. Moreover, gas production was accelerated by leachate recirculation owing to enhancement of waste degradation in landfill columns (C1 and C2). The SGBR pre-operating study showed fast acclimation (5 days) to substrate change and short start-up period (10 days) as evidenced by COD removal efficiencies ranging between 84% and 95% for leachate and non-fat dry milk. Incorporated in a leachate management strategy, the SGBR system was sustained in stability as evidenced by the stable pH and low VFA concentrations. Despite the low organic removal efficiency, the SGBR reactor treating leachate prior to recirculation in the simulated landfill column was effective at reducing the organic matter in leachate within the system. The feasibility of leachate treatment by the SGBR was demonstrated in this study.</p>"],"dc:format.mimetype":["application/pdf"],"dc:identifier":["archive/lib.dr.iastate.edu/rtd/20231/"],"dc:identifier.doi":["https://doi.org/10.31274/rtd-20200817-24"],"dc:identifier.other":["21230","18970506"],"dc:identifier.uri":["https://dr.lib.iastate.edu/handle/20.500.12876/97598"],"dc:language.iso":["en"],"dc:relation.orgunit":["933e9c94-323c-4da9-9e8e-861692825f91"],"dc:subject.keyword":["Civil, construction, and environmental engineering","Civil engineering (Environmental engineering)","Environmental engineering"],"dc:title":["Evaluation of leachate treatment and recycle options using the Static Granular Bed Reactor"],"dc:type":["thesis"],"dspace:entity.type":["Publication"],"local:admin":["isulib-bepress-aws-west","rtd/20231"],"mods:identifier.filename":["archive/lib.dr.iastate.edu/rtd/20231/Park_ISU_2004_P37.pdf|||Fri Jan 14 22:21:50 UTC 2022"],"thesis:degree_discipline":["Civil Engineering (Environmental Engineering)"],"thesis:degree_level":["thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T04:44:32Z"}