{"id":{"repo_id":"indystate","oai_identifier":"oai:scholars.indianastate.edu:etds-4643"},"canonical_url":"https://search.ndltd.org/etd/indystate/oai:scholars.indianastate.edu:etds-4643","repository":{"repo_id":"indystate","name":"Indiana State University","base_url":"https://scholars.indianastate.edu/do/oai/"},"display":{"title":"The Effect of Exercise on the Threshold Frequency of an Electrically Induced Muscle Cramp","abstract":"Context: It has been observed that subjects that have experienced an exercise associated muscle cramp (EAMC) exhibited decreases in the threshold frequency (TF) of an electrical induced muscle cramp (EIMC). Hovvever, it is not known if this change was due to the exercise alone. Objective: To determine if full effort football conditioning exercises cause a shift in TF of an EIMC. Design: A 2 X 2 folly repeated measures factorial design was used for this study. The two independent variables were condition (rest, and exercise), and time (pre, and post). Setting: Subjects: Nine NCAA Division IAA football players participating in conditioning exercises were used as subjects. Main Outcome Measure: The TF of the right flexor hallucis brevis as indicated at the time a 2 sec contraction remained after electrically stimulating the muscle. Results: Data from the 6 subjects (age= 20.50 ± 0.84 yr, height= 185.00 ± 6.89 cm, mass= 112.35 ± 27.27 kg) were used for analysis. The result indicated that neither the interaction of condition by time (Fu= 2.31, P = 0.19), or exercise (F1,s 4.29, P 0.09) altered the TF. Only significant difference was found between pre- and post-conditions (F 15 :== 7.50, P = 0.04) for combined trials. Conclusion: There was no effect of football conditioning exercise on the TF of an EIMC.","abstract_html":"Context: It has been observed that subjects that have experienced an exercise associated muscle cramp (EAMC) exhibited decreases in the threshold frequency (TF) of an electrical induced muscle cramp (EIMC). Hovvever, it is not known if this change was due to the exercise alone. Objective: To determine if full effort football conditioning exercises cause a shift in TF of an EIMC. Design: A 2 X 2 folly repeated measures factorial design was used for this study. The two independent variables were condition (rest, and exercise), and time (pre, and post). Setting: Subjects: Nine NCAA Division IAA football players participating in conditioning exercises were used as subjects. Main Outcome Measure: The TF of the right flexor hallucis brevis as indicated at the time a 2 sec contraction remained after electrically stimulating the muscle. Results: Data from the 6 subjects (age= 20.50 ± 0.84 yr, height= 185.00 ± 6.89 cm, mass= 112.35 ± 27.27 kg) were used for analysis. The result indicated that neither the interaction of condition by time (Fu= 2.31, P = 0.19), or exercise (F1,s 4.29, P 0.09) altered the TF. Only significant difference was found between pre- and post-conditions (F 15 :== 7.50, P = 0.04) for combined trials. Conclusion: There was no effect of football conditioning exercise on the TF of an EIMC.","abstract_has_math":false,"creators":["Sato, Hiroki"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Athletic Training","degree_department":null,"school":null,"contributors":["Marcus B. Stone","Jeffrey E. Edwards","Jody B. Brucker"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T03:21:01Z","subjects":["Exercise associated muscle cramp (EAMC)","Electrically induced muscle cramp (EIMC)","Exercise","EMO","Muscle Contraction","Football"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholars.indianastate.edu/etds/3644","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholars.indianastate.edu/etds/3644","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aindystate%3Aoai%3Ascholars.indianastate.edu%3Aetds-4643","prefix":"oai_dc"},"source_record":{"url":"https://scholars.indianastate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholars.indianastate.edu%3Aetds-4643","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Marcus B. Stone","Jeffrey E. Edwards","Jody B. Brucker"]},{"key":"dc:creator","label":"Author","values":["Sato, Hiroki"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2005-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Athletic Training"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Exercise associated muscle cramp (EAMC)","Electrically induced muscle cramp (EIMC)","Exercise","EMO","Muscle Contraction","Football"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholars.indianastate.edu/etds/3644"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Context: It has been observed that subjects that have experienced an exercise associated muscle cramp (EAMC) exhibited decreases in the threshold frequency (TF) of an electrical induced muscle cramp (EIMC). Hovvever, it is not known if this change was due to the exercise alone. Objective: To determine if full effort football conditioning exercises cause a shift in TF of an EIMC. Design: A 2 X 2 folly repeated measures factorial design was used for this study. The two independent variables were condition (rest, and exercise), and time (pre, and post). Setting: Subjects: Nine NCAA Division IAA football players participating in conditioning exercises were used as subjects. Main Outcome Measure: The TF of the right flexor hallucis brevis as indicated at the time a 2 sec contraction remained after electrically stimulating the muscle. Results: Data from the 6 subjects (age= 20.50 ± 0.84 yr, height= 185.00 ± 6.89 cm, mass= 112.35 ± 27.27 kg) were used for analysis. The result indicated that neither the interaction of condition by time (Fu= 2.31, P = 0.19), or exercise (F1,s 4.29, P 0.09) altered the TF. Only significant difference was found between pre- and post-conditions (F 15 :== 7.50, P = 0.04) for combined trials. Conclusion: There was no effect of football conditioning exercise on the TF of an EIMC."]},{"key":"dc:title","label":"Title","values":["The Effect of Exercise on the Threshold Frequency of an Electrically Induced Muscle Cramp"]}]}],"canonical_facts":{"dc:contributor":["Marcus B. Stone","Jeffrey E. Edwards","Jody B. Brucker"],"dc:creator":["Sato, Hiroki"],"dc:date.created":["2005-08-01T07:00:00Z"],"dc:description.abstract":["Context: It has been observed that subjects that have experienced an exercise associated muscle cramp (EAMC) exhibited decreases in the threshold frequency (TF) of an electrical induced muscle cramp (EIMC). Hovvever, it is not known if this change was due to the exercise alone. Objective: To determine if full effort football conditioning exercises cause a shift in TF of an EIMC. Design: A 2 X 2 folly repeated measures factorial design was used for this study. The two independent variables were condition (rest, and exercise), and time (pre, and post). Setting: Subjects: Nine NCAA Division IAA football players participating in conditioning exercises were used as subjects. Main Outcome Measure: The TF of the right flexor hallucis brevis as indicated at the time a 2 sec contraction remained after electrically stimulating the muscle. Results: Data from the 6 subjects (age= 20.50 ± 0.84 yr, height= 185.00 ± 6.89 cm, mass= 112.35 ± 27.27 kg) were used for analysis. The result indicated that neither the interaction of condition by time (Fu= 2.31, P = 0.19), or exercise (F1,s 4.29, P 0.09) altered the TF. Only significant difference was found between pre- and post-conditions (F 15 :== 7.50, P = 0.04) for combined trials. Conclusion: There was no effect of football conditioning exercise on the TF of an EIMC."],"dc:identifier":["https://scholars.indianastate.edu/etds/3644"],"dc:subject":["Exercise associated muscle cramp (EAMC)","Electrically induced muscle cramp (EIMC)","Exercise","EMO","Muscle Contraction","Football"],"dc:title":["The Effect of Exercise on the Threshold Frequency of an Electrically Induced Muscle Cramp"],"thesis:degree_discipline":["Athletic Training"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T03:21:01Z"}