{"id":{"repo_id":"kent","oai_identifier":"oai:kar.kent.ac.uk:90828"},"canonical_url":"https://search.ndltd.org/etd/kent/oai:kar.kent.ac.uk:90828","repository":{"repo_id":"kent","name":"University of Kent","base_url":"https://kar.kent.ac.uk/cgi/oai2"},"display":{"title":"Optimising a Polygon Mirror-based Spectral Filter for Swept Source Optical Coherence Tomography","abstract":"Optical Coherence Tomography (OCT) is a non-invasive, depth-scan imaging modality with proven applications in medical physics. The benefits of this modality, combined with the range of possible techniques that can be employed, continue to stimulate research and development within this field. One such technique uses a polygon mirror-based spectral filter as a swept light source, and is particularly useful when conducting OCT experiments in a laboratory setting due to its low cost and high versatility. The development of these swept sources has resulted in a variety of experimental designs, however research into the most suitable design needed to fully optimise every aspect for OCT imaging is rarely reported. Ideally, these systems must provide a broad swept bandwidth and produce narrowband, instantaneous laser linewidths, whilst maintaining sufficient optical power levels across the entire spectrum, but it was found that these features can be significantly limited by the design of the spectral filter. The research presented in this thesis is a detailed, multi-parameter analysis of system operation and has resulted in the identification of various techniques that can be applied to improve overall system performance. The polygon mirror-based swept source was studied theoretically, experimentally and using Zemax™ ray tracing simulation software to minimise the effects of mechanical vignetting and maximise the optical power transmission. A design hierarchy was also developed which can be used to determine the most suitable combination of component parameters and the best construction methods needed to optimise the design.","abstract_html":"Optical Coherence Tomography (OCT) is a non-invasive, depth-scan imaging modality with proven applications in medical physics. The benefits of this modality, combined with the range of possible techniques that can be employed, continue to stimulate research and development within this field. One such technique uses a polygon mirror-based spectral filter as a swept light source, and is particularly useful when conducting OCT experiments in a laboratory setting due to its low cost and high versatility. The development of these swept sources has resulted in a variety of experimental designs, however research into the most suitable design needed to fully optimise every aspect for OCT imaging is rarely reported. Ideally, these systems must provide a broad swept bandwidth and produce narrowband, instantaneous laser linewidths, whilst maintaining sufficient optical power levels across the entire spectrum, but it was found that these features can be significantly limited by the design of the spectral filter. The research presented in this thesis is a detailed, multi-parameter analysis of system operation and has resulted in the identification of various techniques that can be applied to improve overall system performance. The polygon mirror-based swept source was studied theoretically, experimentally and using Zemax™ ray tracing simulation software to minimise the effects of mechanical vignetting and maximise the optical power transmission. A design hierarchy was also developed which can be used to determine the most suitable combination of component parameters and the best construction methods needed to optimise the design.","abstract_has_math":false,"creators":["Everson, Michael"],"institution":"University of Kent,","degree_name":"phd","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Dobre, George"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-10","date_published":"2021-10","updated_at":"2026-11-25T20:20:01Z","subjects":["Q Science"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://kar.kent.ac.uk/90828/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://kar.kent.ac.uk/90828/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Akent%3Aoai%3Akar.kent.ac.uk%3A90828","prefix":"oai_dc"},"source_record":{"url":"https://kar.kent.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Akar.kent.ac.uk%3A90828","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dobre, George"]},{"key":"dc:creator","label":"Author","values":["Everson, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-10"]},{"key":"dc:date.issued","label":"Date","values":["2021-10"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physical Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Kent,"]},{"key":"dc:relation.isreferencedby.uri","label":"Dc Relation Isreferencedby URI","values":["https://doi.org/10.22024/UniKent/01.02.90828"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Q Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://kar.kent.ac.uk/90828/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Optical Coherence Tomography (OCT) is a non-invasive, depth-scan imaging modality with proven applications in medical physics. The benefits of this modality, combined with the range of possible techniques that can be employed, continue to stimulate research and development within this field. One such technique uses a polygon mirror-based spectral filter as a swept light source, and is particularly useful when conducting OCT experiments in a laboratory setting due to its low cost and high versatility. The development of these swept sources has resulted in a variety of experimental designs, however research into the most suitable design needed to fully optimise every aspect for OCT imaging is rarely reported. Ideally, these systems must provide a broad swept bandwidth and produce narrowband, instantaneous laser linewidths, whilst maintaining sufficient optical power levels across the entire spectrum, but it was found that these features can be significantly limited by the design of the spectral filter. The research presented in this thesis is a detailed, multi-parameter analysis of system operation and has resulted in the identification of various techniques that can be applied to improve overall system performance. The polygon mirror-based swept source was studied theoretically, experimentally and using Zemax™ ray tracing simulation software to minimise the effects of mechanical vignetting and maximise the optical power transmission. A design hierarchy was also developed which can be used to determine the most suitable combination of component parameters and the best construction methods needed to optimise the design."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Optimising a Polygon Mirror-based Spectral Filter for Swept Source Optical Coherence Tomography"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dobre, George"],"dc:creator":["Everson, Michael"],"dc:date":["2021-10"],"dc:date.issued":["2021-10"],"dc:description.abstract":["Optical Coherence Tomography (OCT) is a non-invasive, depth-scan imaging modality with proven applications in medical physics. The benefits of this modality, combined with the range of possible techniques that can be employed, continue to stimulate research and development within this field. One such technique uses a polygon mirror-based spectral filter as a swept light source, and is particularly useful when conducting OCT experiments in a laboratory setting due to its low cost and high versatility. The development of these swept sources has resulted in a variety of experimental designs, however research into the most suitable design needed to fully optimise every aspect for OCT imaging is rarely reported. Ideally, these systems must provide a broad swept bandwidth and produce narrowband, instantaneous laser linewidths, whilst maintaining sufficient optical power levels across the entire spectrum, but it was found that these features can be significantly limited by the design of the spectral filter. The research presented in this thesis is a detailed, multi-parameter analysis of system operation and has resulted in the identification of various techniques that can be applied to improve overall system performance. The polygon mirror-based swept source was studied theoretically, experimentally and using Zemax™ ray tracing simulation software to minimise the effects of mechanical vignetting and maximise the optical power transmission. A design hierarchy was also developed which can be used to determine the most suitable combination of component parameters and the best construction methods needed to optimise the design."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://kar.kent.ac.uk/90828/"],"dc:language":["en"],"dc:publisher.department":["Physical Sciences"],"dc:publisher.institution":["University of Kent,"],"dc:relation.isreferencedby.uri":["https://doi.org/10.22024/UniKent/01.02.90828"],"dc:subject":["Q Science"],"dcterms:accessrights":["public"],"dc:title":["Optimising a Polygon Mirror-based Spectral Filter for Swept Source Optical Coherence Tomography"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["phd"]},"updated_at":"2026-11-25T20:20:01Z"}