{"id":{"repo_id":"ksu","oai_identifier":"oai:krex.k-state.edu:2097/1044"},"canonical_url":"https://search.ndltd.org/etd/ksu/oai:krex.k-state.edu:2097/1044","repository":{"repo_id":"ksu","name":"Kansas State University","base_url":"https://krex.k-state.edu/server/oai/request"},"display":{"title":"Using IR thermography to determine the heat flux removed by spray cooling a high-temperature metallic surface","abstract":"A significant body of literature exists for experiments in spray cooling applications that utilize one-dimensional heat transfer through a metal ingot to determine the average surface heat flux. Due to inherent non-uniformities in spray distributions, measurements that account for the two-dimensional effects are required. In this study, an infrared (IR) camera was used to capture the two-dimensional temperature distribution formed when spraying an electrically heated NiChrome surface with three different fluids. IR thermography captured the thermal response of the un-sprayed side of a 0.005-inch (0.125mm) think strip of NiChrome exposed to spray from a 90° full-cone nozzle at low mass fluxes (0.025 – 0.045 lb/ft[superscript]2-s / 0.122 – 0.220 kg/m[superscript]2-s) from a distance of approximately 5 to 11 inches (13 to 28cm). Results were measured for surface average temperatures ranging from 150 to 600°F (65 – 315°C).","abstract_html":"A significant body of literature exists for experiments in spray cooling applications that utilize one-dimensional heat transfer through a metal ingot to determine the average surface heat flux. Due to inherent non-uniformities in spray distributions, measurements that account for the two-dimensional effects are required. In this study, an infrared (IR) camera was used to capture the two-dimensional temperature distribution formed when spraying an electrically heated NiChrome surface with three different fluids. IR thermography captured the thermal response of the un-sprayed side of a 0.005-inch (0.125mm) think strip of NiChrome exposed to spray from a 90° full-cone nozzle at low mass fluxes (0.025 – 0.045 lb/ft[superscript]2-s / 0.122 – 0.220 kg/m[superscript]2-s) from a distance of approximately 5 to 11 inches (13 to 28cm). Results were measured for surface average temperatures ranging from 150 to 600°F (65 – 315°C).","abstract_has_math":false,"creators":["Pedotto, Cristina"],"institution":"Kansas State University","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Department of Mechanical and Nuclear Engineering","school":null,"contributors":[],"advisors":["Bruce R. Babin"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-12-08T14:58:24Z","date_published":"2008-12-08T14:58:24Z","updated_at":"2026-11-26T03:10:26Z","subjects":["Spray Cooling","Phase Change","Heat Transfer"],"languages":["en_US"],"rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2097/1044","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2097/1044","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aksu%3Aoai%3Akrex.k-state.edu%3A2097%2F1044","prefix":"oai_dc"},"source_record":{"url":"https://krex.k-state.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Akrex.k-state.edu%3A2097%2F1044","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Mechanical and Nuclear Engineering"]},{"key":"dc:creator","label":"Author","values":["Pedotto, Cristina"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-12-08T14:58:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-12-08T14:58:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-12-08T14:58:24Z"]},{"key":"dc:date.published","label":"Dc Date Published","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Kansas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_date","label":"Thesis Degree Date","values":["December"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spray Cooling","Phase Change","Heat Transfer"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, General (0537)","Engineering, Mechanical (0548)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/2097/1044"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A significant body of literature exists for experiments in spray cooling applications that utilize one-dimensional heat transfer through a metal ingot to determine the average surface heat flux. Due to inherent non-uniformities in spray distributions, measurements that account for the two-dimensional effects are required. In this study, an infrared (IR) camera was used to capture the two-dimensional temperature distribution formed when spraying an electrically heated NiChrome surface with three different fluids. IR thermography captured the thermal response of the un-sprayed side of a 0.005-inch (0.125mm) think strip of NiChrome exposed to spray from a 90° full-cone nozzle at low mass fluxes (0.025 – 0.045 lb/ft[superscript]2-s / 0.122 – 0.220 kg/m[superscript]2-s) from a distance of approximately 5 to 11 inches (13 to 28cm). Results were measured for surface average temperatures ranging from 150 to 600°F (65 – 315°C)."]},{"key":"dc:description.advisor","label":"Dc Description Advisor","values":["Bruce R. Babin"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["BAE Systems"]},{"key":"dc:title","label":"Title","values":["Using IR thermography to determine the heat flux removed by spray cooling a high-temperature metallic surface"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Mechanical and Nuclear Engineering"],"dc:creator":["Pedotto, Cristina"],"dc:date.accessioned":["2008-12-08T14:58:24Z"],"dc:date.available":["2008-12-08T14:58:24Z"],"dc:date.issued":["2008-12-08T14:58:24Z"],"dc:date.published":["2008"],"dc:description.abstract":["A significant body of literature exists for experiments in spray cooling applications that utilize one-dimensional heat transfer through a metal ingot to determine the average surface heat flux. Due to inherent non-uniformities in spray distributions, measurements that account for the two-dimensional effects are required. In this study, an infrared (IR) camera was used to capture the two-dimensional temperature distribution formed when spraying an electrically heated NiChrome surface with three different fluids. IR thermography captured the thermal response of the un-sprayed side of a 0.005-inch (0.125mm) think strip of NiChrome exposed to spray from a 90° full-cone nozzle at low mass fluxes (0.025 – 0.045 lb/ft[superscript]2-s / 0.122 – 0.220 kg/m[superscript]2-s) from a distance of approximately 5 to 11 inches (13 to 28cm). Results were measured for surface average temperatures ranging from 150 to 600°F (65 – 315°C)."],"dc:description.advisor":["Bruce R. Babin"],"dc:description.degree":["Master of Science"],"dc:description.sponsorship":["BAE Systems"],"dc:identifier.uri":["http://hdl.handle.net/2097/1044"],"dc:language.iso":["en_US"],"dc:publisher":["Kansas State University"],"dc:rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Spray Cooling","Phase Change","Heat Transfer"],"dc:subject.proquest":["Engineering, General (0537)","Engineering, Mechanical (0548)"],"dc:title":["Using IR thermography to determine the heat flux removed by spray cooling a high-temperature metallic surface"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_date":["December"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-26T03:10:26Z"}